Comparison of 1-year Follow-up Echocardiographic Outcomes of Sapien 3 Versus Evolut R Bioprosthetic Transcatheter Aortic Valves: A Single-center Retrospective Iranian Cohort Study

Objective: The current study aimed to compare 1-year echocardiographic outcomes of the new generations of self-expanding (Evolut R) versus balloon-expandable (Sapien 3) bioprosthetic transcatheter aortic valves. Methods: In this study, gradients and flow velocities obtained from transthoracic Doppler-echocardiography were retrospectively collected from patients who underwent 2 new generations of transcatheter aortic valve implantation interventions with Sapien 3 and Evolut R valves. Patients underwent echocardiography before the procedure and at discharge, 6 months, and 1-year follow-up. Results: Of the 66 patients, 28 received Sapien 3 and 38 received Evolut R valves. Evolut R valve presented a lower mean gradient at all follow-up time points compared with Sapien 3 valves (14.4 mm Hg, 14.9 mm Hg, 15.5 mm Hg compared with 10.1 mm Hg, 11.6 mm Hg, 11.8 mm Hg, respectively; all P-values <0.001). Small valve sizes of Evolut R, including 23 and 26, had higher echocardiographic mean gradient or peak gradient at the time of discharge compared with larger valves, including sizes 29 and 34 (11.1 mm Hg and 11.2 mm Hg vs. 10.2 mm Hg, 9.1 mm Hg) and 1-year follow-up (11.0 mm Hg, 11.0 mm Hg vs. 9.9 mm Hg, 8.4 mm Hg; all P-values = 0.001). Although Sapien 3 valves demonstrated a higher peak gradient in smaller sizes at discharge (18.44 mm Hg in size 23 vs. 17.9 mm Hg, 16.5 mm Hg in size 26 and 29, respectively; P = 0.001), the peak gradients did not show a statistically significant difference in the 1-year follow-up. Conclusions: The current study detected significantly lower mean and peak gradients in Evolut R compared with Sapien 3 at all follow-up time points. Furthermore, smaller valve sizes were associated with significantly higher gradients at all follow-ups, regardless of the valve type.

[1]  G. Tarantini,et al.  Real-World Multiple Comparison of Transcatheter Aortic Valves: Insights From the Multicenter OBSERVANT II Study , 2022, Circulation. Cardiovascular interventions.

[2]  R. Kornowski,et al.  Meta-analysis of short- and long-term clinical outcomes of the self-expanding Evolut R/pro valve versus the balloon-expandable Sapien 3 valve for transcatheter aortic valve implantation. , 2022, International journal of cardiology.

[3]  L. Dasi,et al.  Comparison of Catheterization Versus Echocardiographic-Based Gradients in Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation. , 2022, The Journal of invasive cardiology.

[4]  P. Pibarot,et al.  Balloon- Versus Self-Expanding Valve Systems for Treating Small Failed Surgical Aortic Bioprostheses: The LYTEN Trial. , 2022, Journal of the American College of Cardiology.

[5]  R. Nishimura,et al.  Measuring Pressure Gradients After Transcatheter Aortic Valve Implantation: Rethinking the Bernoulli Principle , 2021, Journal of the American Heart Association.

[6]  P. Pibarot,et al.  Comparison of Transvalvular Aortic Mean Gradients Obtained by Intraprocedural Echocardiography and Invasive Measurement in Balloon and Self‐Expanding Transcatheter Valves , 2021, Journal of the American Heart Association.

[7]  B. Prendergast,et al.  2021 ESC/EACTS Guidelines for the management of valvular heart disease. , 2021, European heart journal.

[8]  T. Nagai,et al.  Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement , 2021, Journal of Cardiovascular Magnetic Resonance.

[9]  G. Santarpino,et al.  Comparison between Surgical Access and Percutaneous Closure Device in 787 Patients Undergoing Transcatheter Aortic Valve Replacement , 2021, Journal of clinical medicine.

[10]  J. Leipsic,et al.  Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk. , 2021, Journal of the American College of Cardiology.

[11]  S. Kohsaka,et al.  Transcatheter Aortic Valve Replacement in Patients With a Small Annulus - From the Japanese Nationwide Registry (J-TVT). , 2021, Circulation journal : official journal of the Japanese Circulation Society.

[12]  L. Gonzalez-Ciccarelli,et al.  Pressure Recovery Phenomenon in Aortic Stenosis. An Inconvenient Truth? , 2021, Journal of cardiothoracic and vascular anesthesia.

[13]  K. Fukuda,et al.  Transcatheter aortic valve replacement with Evolut R versus Sapien 3 in Japanese patients with a small aortic annulus: The OCEAN‐TAVI registry , 2020, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[14]  Shao‐Wei Chen,et al.  Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis , 2020, PloS one.

[15]  Yi-ming Li,et al.  Comparison of third generation balloon-expandable Edwards Sapien 3 versus self-expandable Evolut R in transcatheter aortic valve implantation: a meta-analysis. , 2020, Annals of palliative medicine.

[16]  F. Neumann,et al.  5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial. , 2020, JACC. Cardiovascular interventions.

[17]  I. König,et al.  Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. , 2020, European heart journal.

[18]  T. James,et al.  Predictors and outcomes of patient‐prosthesis mismatch after transcatheter aortic valve replacement , 2019, Journal of cardiac surgery.

[19]  L. Dasi,et al.  Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves , 2019, Annals of Biomedical Engineering.

[20]  L. Fauchier,et al.  Impact of Sapien 3 Balloon-Expandable Versus Evolut R Self-Expandable Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis , 2019, Circulation.

[21]  P. Leprince,et al.  Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement , 2019, Circulation.

[22]  A. Huber,et al.  Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses. , 2019, JACC. Cardiovascular interventions.

[23]  B. Prendergast,et al.  Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis. , 2019, European heart journal.

[24]  Chenglin He,et al.  Safety and efficacy of self-expandable Evolut R vs. balloon-expandable Sapien 3 valves for transcatheter aortic valve implantation: A systematic review and meta-analysis , 2019, Experimental and therapeutic medicine.

[25]  P. D. de Jaegere,et al.  Differences in clinical valve size selection and valve size selection for patient-specific computer simulation in transcatheter aortic valve replacement (TAVR): a retrospective multicenter analysis , 2019, The International Journal of Cardiovascular Imaging.

[26]  J. Leipsic,et al.  Transcatheter Aortic‐Valve Replacement with a Balloon‐Expandable Valve in Low‐Risk Patients , 2019, The New England journal of medicine.

[27]  Andrew S. Mugglin,et al.  Transcatheter Aortic‐Valve Replacement with a Self‐Expanding Valve in Low‐Risk Patients , 2019, The New England journal of medicine.

[28]  J. Schofer,et al.  Performance of the Evolut‐R 34 mm versus Sapien‐3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut‐R 34 mm as compared with Sapien‐3 29 mm in patients with Annuli ≥26 mm , 2018, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[29]  J. G. D. Diego,et al.  Comparación de la hemodinámica valvular de la prótesis transcatéter con balón expandible SAPIEN 3 frente a la autoexpandible Evolut R: estudio de casos emparejados , 2018, Revista Española de Cardiología.

[30]  Prem A. Midha,et al.  The Fluid Mechanics of Transcatheter Heart Valve Leaflet Thrombosis in the Neosinus , 2017, Circulation.

[31]  M. Salarifar,et al.  Initial Experiences of Transcatheter Aortic Valve Implantation (TAVI) In Iran with Midterm Follow up , 2017 .

[32]  G. Gerosa,et al.  Long-term outcomes and prosthesis performance after transcatheter aortic valve replacement: results of self-expandable and balloon-expandable transcatheter heart valves. , 2017, Annals of cardiothoracic surgery.

[33]  Y. Arbel,et al.  Comparison of the Edwards SAPIEN S3 Versus Medtronic Evolut-R Devices for Transcatheter Aortic Valve Implantation. , 2017, The American journal of cardiology.

[34]  C. Căldăraru,et al.  Modern Use of Echocardiography in Transcatheter Aortic Valve Replacement: an Up-Date. , 2016, Maedica.

[35]  M. Mack,et al.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. , 2016, The New England journal of medicine.

[36]  I. Meredith,et al.  Treatment of Symptomatic Severe Aortic Stenosis With a Novel Resheathable Supra-Annular Self-Expanding Transcatheter Aortic Valve System. , 2015, JACC. Cardiovascular interventions.

[37]  R. Siegel,et al.  Left ventricular hypertrophy in valvular aortic stenosis: mechanisms and clinical implications. , 2015, The American journal of medicine.

[38]  S. Kaul Transcatheter aortic-valve replacement with a self-expanding prosthesis. , 2014, The New England journal of medicine.

[39]  Maurice Buchbinder,et al.  Transcatheter aortic-valve replacement with a self-expanding prosthesis. , 2014, The New England journal of medicine.

[40]  A. Bogers,et al.  Aortic stenosis in the elderly: disease prevalence and number of candidates for transcatheter aortic valve replacement: a meta-analysis and modeling study. , 2013, Journal of the American College of Cardiology.

[41]  J. Leipsic,et al.  Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve. , 2013, JACC. Cardiovascular interventions.

[42]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[43]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[44]  B. Lytle,et al.  Aortic valve replacement: is valve size important? , 2000, The Journal of thoracic and cardiovascular surgery.

[45]  H. Baumgartner,et al.  Importance of pressure recovery for the assessment of aortic stenosis by Doppler ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro. , 1996, Circulation.

[46]  S. I. Seldinger Catheter replacement of the needle in percutaneous arteriography. A new technique. , 1953, Acta radiologica. Supplement.

[47]  S. Kennon,et al.  Transcatheter Aortic Valve Implantation Without General Anaesthetic. , 2014, Interventional cardiology.