ENHANCEMENT OF POWER QUALITY IN GRID-CONNECTED DOUBLY FED WIND TURBINES INDUCTION GENERATOR

Wind power technology is expanding rapidly, more and more wind farms are being connected to the power systems. Incorporation of large scale wind farms presents various challenges that must be tackled, such as system operation and control, stability, reliability and power quality. Power quality problems such as voltage flicker and harmonic distortion due to non-linear loads, sags due to faults are some major issues considered in this paper. Doubly fed Wind turbine induction generator connected to a grid is analyzed using MATLAB/ SIMULINK. Owing to continuously varying wind speed components, the active and reactive power along with terminal voltage fluctuates unremittingly. The proposed wind electric generators use good control techniques to extract maximum power at the every available speed and to mitigate harmonics and other power quality issues.

[1]  A. Testa,et al.  IEEE Recommended Practice— Adoption of IEC 61000-4-15:2010, Electromagnetic compatibility (EMC)—Testing and measurement techniques—Flickermeter— Functional and design specifications , 2011 .

[2]  G. Gerdes,et al.  Power quality of wind turbines and their interaction with the grid , 1995 .

[3]  J. Julio Gutiérrez,et al.  A Review of Flicker Severity Assessment by the IEC Flickermeter , 2010, IEEE Transactions on Instrumentation and Measurement.

[4]  José Julio Gutiérrez,et al.  Flicker Measurement System for Wind Turbine Certification , 2007, IMTC 2007.

[5]  Z. Chen Issues of Connecting Wind Farms into Power Systems , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[6]  A. Larsson,et al.  Flicker Emission of Wind Turbines during Continuous Operation , 2002, IEEE Power Engineering Review.

[7]  F. Blaabjerg,et al.  Flicker study on variable speed wind turbines with doubly fed induction generators , 2005, IEEE Transactions on Energy Conversion.

[8]  E. Akpinar,et al.  Power quality analysis of wind farm connected to Alaçatı substation in Turkey , 2009 .

[9]  Torbjörn Thiringer,et al.  Power quality measurements performed on a low-voltage grid equipped with two wind turbines , 1996 .

[10]  J. Julio Gutiérrez,et al.  Flicker Measurement System for Wind Turbine Certification , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[11]  B. Grainger,et al.  Beyond the harbour wall [offshore wind farm] , 2001 .

[12]  J. Usaola,et al.  Frequency domain analysis of flicker produced by wind energy conversions systems , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).