Multivariate curve resolution-alternating least squares assisted by voltammetry for simultaneous determination of betaxolol and atenolol using carbon nanotube paste electrode.

In the present work differential pulse voltammetry coupled with multivariate curve resolution-alternating least squares (MCR-ALS) was applied for simultaneous determination of betaxolol (Bet) and atenolol (Ate) in 0.20 M Britton-Robinson (B-R) buffer solution at the surface of a multi-walled carbon nanotube modified carbon paste electrode (MWCNT/CPE). Characterization of the modified electrode was carried out by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A strategy based on experimental design was followed. Operating conditions were improved with central composite rotatable design (CCRD) and response surface methodology (RSM), involving several chemical and instrumental parameters. Then second order data were built from variable pulse heights of DPV and after correction in potential shift analyzed by MCR-ALS. Analytical parameters such as linearity, repeatability, and stability were also investigated and a detection limit (DL) of 0.19 and 0.29 μM for Bet and Ate was achieved, respectively. The proposed method was successfully applied in simultaneous determining the two analytes in human plasma.

[1]  M. Esteban,et al.  Combined use of the potential shift correction and the simultaneous treatment of spectroscopic and electrochemical data by multivariate curve resolution: analysis of a Pb(II)-phytochelatin system. , 2008, The Analyst.

[2]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[3]  R. Tauler,et al.  Application of multivariate curve resolution to the voltammetric study of the complexation of fulvic acids with cadmium(II) ion , 2002 .

[4]  R. Rocha‐Filho,et al.  Square-wave voltammetric determination of propranolol and atenolol in pharmaceuticals using a boron-doped diamond electrode. , 2010, Talanta.

[5]  Alejandro C Olivieri,et al.  New Robust Bilinear Least Squares Method for the Analysis of Spectral-pH Matrix Data , 2005, Applied spectroscopy.

[6]  José Manuel Amigo,et al.  A mixed hard- and soft-modelling approach for the quantitative determination of oxipurines and uric acid in human urine , 2006 .

[7]  M. Behpour,et al.  Determination of Trace Amounts of Sulfamethizole Using a Multi-Walled Carbon Nanotube Modified Electrode: Application of Experimental Design in Voltammetric Studies , 2013 .

[8]  F. Ohsuzu,et al.  Effect of betaxolol hydrochloride on heart rate variability indices during exercise stress testing in patients with hypertension. , 2005, Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie.

[9]  Jing-Juan Xu,et al.  Electrochemically deposited chitosan hydrogel for horseradish peroxidase immobilization through gold nanoparticles self-assembly. , 2005, Biosensors & bioelectronics.

[10]  R. Tauler,et al.  CADMIUM-BINDING PROPERTIES OF GLUTATHIONE: A CHEMOMETRICAL ANALYSIS OF VOLTAMMETRIC DATA , 1997 .

[11]  H. Saleh,et al.  Colorimetric determination of β-blockers in pharmaceutical formulations , 2002 .

[12]  Miquel Esteban,et al.  Multivariate curve resolution with alternating least squares optimisation: a soft-modelling approach to metal complexation studies by voltammetric techniques , 2000 .

[13]  M. Esteban,et al.  Soft modelling for the resolution of highly overlapped voltammetric peaks: application to some Pb-phytochelatin systems. , 2007, Talanta.

[14]  M. Esteban,et al.  Complexation of heavy metals by phytochelatins: voltammetric study of the binding of Cd2+ and Zn2+ ions by the phytochelatin (gamma-Glu-Cys)3Gly assisted by multivariate curve resolution. , 2005, Environmental science & technology.

[15]  M. Esteban,et al.  Binding of Cd2+ and Zn2+ with the Phytochelatin (γ‐Glu‐Cys)4‐Gly: A Voltammetric Study Assisted by Multivariate Curve Resolution and Electrospray Ionization Mass Spectrometry , 2007 .

[16]  Frederick S. Hillier,et al.  Introduction of Operations Research , 1967 .

[17]  Dan Wu,et al.  Graphene-Based Optical and Electrochemical Biosensors: A Review , 2013 .

[18]  Hamid Abdollahi,et al.  Second-Order Data Obtained from Differential Pulse Voltammetry: Determination of Lead in River Water Using Multivariate Curve Resolution-Alternating Least-Squares (MCR-ALS) , 2010 .

[19]  Y. Ni,et al.  Voltammetric behavior of complexation of salbutamol with calf thymus DNA and its analytical application. , 2011, Analytical biochemistry.

[20]  C. Huck,et al.  GC-MS method for the simultaneous determination of β-blockers, flavonoids, isoflavones and their metabolites in human urine. , 2011, Journal of pharmaceutical and biomedical analysis.

[21]  R. Goyal,et al.  Voltammetric determination of atenolol at C(60)-modified glassy carbon electrodes. , 2006, Talanta.

[22]  Richard G. Brereton,et al.  Applied Chemometrics for Scientists , 2007 .

[23]  B. Kowalski,et al.  Selectivity, local rank, three‐way data analysis and ambiguity in multivariate curve resolution , 1995 .

[24]  M. P. Callao,et al.  Analytical applications of second-order calibration methods. , 2008, Analytica chimica acta.

[25]  S. Magiera,et al.  HPLC method for the simultaneous determination of-blockers , isoflavones nd their metabolites in human urine , 2011 .

[26]  I. Šestáková,et al.  Adsorptive accumulation in constant current stripping chronopotentiometry as an alternative for the electrochemical study of metal complexation by thiol-containing peptides , 2006 .

[27]  R. Tauler,et al.  Multivariate curve resolution analysis of voltammetric data obtained at different time windows: study of the system Cd2+–nitrilotriacetic acid , 1998 .

[28]  M. Esteban,et al.  Differential pulse voltammetric study of the complexation of Cd(II) by the phytochelatin (γ-GluCys)2Gly assisted by multivariate curve resolution , 2002 .

[29]  J. Carstensen,et al.  Aligning of single and multiple wavelength chromatographic profiles for chemometric data analysis using correlation optimised warping , 1998 .

[30]  K. Markides,et al.  Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data. , 2002, Journal of chromatography. A.

[31]  M. Esteban,et al.  Cadmium Binding Properties of the C-Terminal Hexapeptide from Mouse Metallothionein. Study by Linear Sweep Voltammetry and Multivariate Curve Resolution Analysis. , 1999 .

[32]  D. Massart,et al.  A comparison of two algorithms for warping of analytical signals , 2002 .

[33]  Huan Yu,et al.  Simultaneous determination of three β-blockers at a carbon nanofiber paste electrode by capillary electrophoresis coupled with amperometric detection. , 2012, Talanta.

[34]  Rajendra N. Goyal,et al.  Differential pulse voltammetric determination of atenolol in pharmaceutical formulations and urine using nanogold modified indium tin oxide electrode , 2006 .

[35]  Jianshe Huang,et al.  Determination of Atenolol and Metoprolol by Capillary Electrophoresis with Tris(2,2′-bipyridyl)ruthenium(II) Electrochemiluminescence Detection , 2007, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[36]  S. Ferreira,et al.  Application of Multivariate Techniques in Optimization of Spectroanalytical Methods , 2007 .

[37]  R. Tauler,et al.  Application of multivariate curve resolution to voltammetric data. Part 1. Study of Zn(II) complexation with some polyelectrolytes , 1995 .

[38]  D. Doğrukol-Ak,et al.  Determination of Sotalol in Tablets and Serum by CZE , 2007 .

[39]  M. Esteban,et al.  Competitive binding of cadmium by plant thiols: an electrochemical study assisted by multivariate curve resolution , 2009, Analytical and bioanalytical chemistry.