Whole‐heart cine MRI using real‐time respiratory self‐gating

Two‐dimensional (2D) breath‐hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three‐dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods, even those that use undersampling techniques, involve breath‐holding for periods that are too long for many patients. Free‐breathing respiratory gating sequences represent a possible solution for realizing 3D cine imaging. A real‐time respiratory self‐gating technique for whole‐heart cine MRI is presented. The technique enables assessment of cardiac anatomy and function with minimum planning or patient cooperation. Nonangulated isotropic 3D data were acquired from five healthy volunteers and then reformatted into 2D clinical views. The respiratory self‐gating technique is shown to improve image quality in free‐breathing scanning. In addition, ventricular volumetric data obtained using the 3D approach were comparable to those acquired with the conventional multislice 2D approach. Magn Reson Med 57:606–613, 2007. © 2007 Wiley‐Liss, Inc.

[1]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[2]  C J Hardy,et al.  Continual NMR cardiography without gating: M-mode MR imaging. , 1990, Radiology.

[3]  S. T. Nichols,et al.  Quantitative evaluation of several partial fourier reconstruction algorithms used in mri , 1993, Magnetic resonance in medicine.

[4]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[5]  A. Redington,et al.  Cardiopulmonary interactions after Fontan operations: augmentation of cardiac output using negative pressure ventilation. , 1997, Circulation.

[6]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[7]  M. Yacoub,et al.  Asymmetric redirection of flow through the heart , 2000, Nature.

[8]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[9]  Dudley J Pennell,et al.  Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. , 2002, The American journal of cardiology.

[10]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[11]  Manojkumar Saranathan,et al.  Coronary MR angiography: Respiratory motion correction with BACSPIN , 2003, Journal of magnetic resonance imaging : JMRI.

[12]  Vivek Muthurangu,et al.  Three-dimensional magnetic resonance imaging of congenital cardiac anomalies , 2003, Cardiology in the Young.

[13]  E. M. Pedersen,et al.  Operator-Independent Isotropic Three-Dimensional Magnetic Resonance Imaging for Morphology in Congenital Heart Disease: A Validation Study , 2004, Circulation.

[14]  Andrew C Larson,et al.  Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.

[15]  P. Börnert,et al.  Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction , 2005, Magnetic resonance in medicine.

[16]  Andrew C Larson,et al.  Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRI , 2005, Magnetic resonance in medicine.