Free‐breathing 3D coronary MRA: The impact of “Isotropic” image resolution

During conventional x‐ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three‐dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real‐time navigator‐gated and corrected free‐breathing interleaved echoplanar (TFE‐EPI) 3D‐MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 × 1.5 × 3.0 mm, 10 slices) and one with “near” isotropic (1.0 × 1.5 × 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% ± 5% vs. 42% ± 5%; P = NS) between in‐plane and through‐plane views with “isotropic” voxel size but differed (32% ± 7% vs. 23% ± 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through‐plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in‐plane reconstructions. Vessel diameter measurements were view independent (2.81 ± 0.45 mm vs. 2.66 ± 0.52 mm; P = NS) for isotropic, but differed (2.71 ± 0.51 mm vs. 3.30 ± 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 ± 0:57 minutes for anisotropic and 7:11 ± 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for “near” isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x‐ray angiography are needed to investigate the clinical utility of the isotropic strategy. J. Magn. Reson. Imaging 2000;11:389–393. © 2000 Wiley‐Liss, Inc.

[1]  René M. Botnar,et al.  Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging. , 1999, AJR. American journal of roentgenology.

[2]  P J de Feyter,et al.  Breath-hold coronary MR angiography with volume-targeted imaging. , 1998, Radiology.

[3]  Albert Macovski,et al.  Coronary Angiography with Magnetization‐Prepared T2 Contrast , 1995, Magnetic resonance in medicine.

[4]  Todd S. Sachs,et al.  Fast magnetic resonance coronary angiography with a three‐dimensional stack of spirals trajectory , 1999, Magnetic resonance in medicine.

[5]  René M. Botnar,et al.  Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. , 1999, Circulation.

[6]  Centric ordering is superior to gradient moment nulling for motion artifact reduction in EPI , 1997, Journal of magnetic resonance imaging : JMRI.

[7]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[8]  G. Krinsky,et al.  Gadolinium-enhanced three-dimensional MR angiography of the thoracoabdominal aorta. , 1996, Seminars in ultrasound, CT, and MR.

[9]  René M. Botnar,et al.  Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography. , 1999, Journal of the American College of Cardiology.

[10]  Rachid Deriche,et al.  Fast algorithms for low-level vision , 1988, [1988 Proceedings] 9th International Conference on Pattern Recognition.

[11]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.