Petersen Coil Regulators Analysis Using a Real-Time Digital Simulator

In order to study new technologies, in sight of smart grids, and for new regulation, protection, and control devices homologation tests, it becomes essential to use a real-time digital simulator (RTDS). This calculator offers the possibility to analyze the behavior of the aforementioned devices in any electrical grid condition, especially those hardly reproducible on the real field. In this paper, the analysis of two types of Petersen Coil Regulators will be discussed, focusing on the experimental results reached, useful to gain an optimized electrical distribution grid management.

[1]  G. Valtorta,et al.  Temporary overvoltages due to ground faults in MV networks , 2009 .

[2]  Paul M. Anderson Power System Protection , 1998 .

[3]  Edith Clarke,et al.  Circuit analysis of A-C power systems , 1950 .

[4]  L.H. Tsoukalas,et al.  From smart grids to an energy internet: Assumptions, architectures and requirements , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[5]  Vincent Del Toro,et al.  Electric Power Systems , 1991 .

[6]  W. Marsden I and J , 2012 .

[7]  S. Conti,et al.  Innovative solutions for protection schemes in autonomous MV micro-grids , 2009, 2009 International Conference on Clean Electrical Power.

[8]  B. Ceresoli,et al.  Neutral connection to earth in medium voltage networks: operation experience in enel , 2001 .

[9]  M. McGranaghan,et al.  Functions of a local controller to coordinate distributed resources in a smart grid , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[10]  Y. Harmand,et al.  A new deal for safety and quality on MV networks , 1997 .

[11]  Jin-O Kim,et al.  Dynamic characteristic test of protective relay for double circuit using real time digital simulator (RTDS) , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[12]  Gianluca Sapienza,et al.  Smart Grids: preliminary MV network model using real time digital simulator and real devices in a closed loop control , 2009 .

[13]  T. Maguire,et al.  Small Time-step ( < 2μSec ) VSC Model for the Real Time Digital Simulator , 2005 .

[14]  Joseph Maire,et al.  A ROADMAP FOR DEVELOPING REAL TIME DISTRIBUTION SYSTEM SIMULATION TOOLS FOR THE SMART GRID , 2008 .

[15]  Andreas Kugi,et al.  NEW METHOD TO CONTROL PETERSEN COILS BY INJECTION OF TWO FREQUENCIES , 2005 .

[16]  N.N. Schulz,et al.  Real time power system simulation using RTDS and NI PXI , 2008, 2008 40th North American Power Symposium.

[17]  Yang Yihan,et al.  Research on a new compensation mode in MV power network , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[18]  Walker L. Cisler,et al.  Electric Power Systems and Nuclear Power , 1952 .