Genetic-Based Underfrequency Load Shedding in a Stand-Alone Power System Considering Fuzzy Loads

For the operators of a power system, underfrequency load shedding is important for maintaining the system in a stable and reliable state whenever it suffers from a severe disturbance. The underfrequency relay protects the power system against a blackout when the system frequency declines to predetermined settings. This paper determines the shed load at each stage for the underfrequency relay (81L). The genetic algorithm (GA) is employed to minimize the shed load and maximize the lowest swing frequency. Penalty functions and chromosomes with varying lengths are utilized in the GA to determine the optimal shed loads at all stages. The uncertainty in bus loads is modeled by a fuzzy set. A stand-alone power system with diesel and wind-power generators is adopted to demonstrate the applicability of the proposed method.

[1]  D. Agoris,et al.  Method Combining ANNs and Monte Carlo Simulation for the Selection of the Load Shedding Protection Strategies in Autonomous Power Systems , 2006, IEEE Transactions on Power Systems.

[2]  Vladimir Terzija Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006 .

[3]  Hans-Jürgen Zimmermann,et al.  Fuzzy Set Theory - and Its Applications , 1985 .

[4]  Elsaid Ibrahim Ammar Interactive stability of multiobjective NLP problems with fuzzy parameters in the objective functions and constraints , 2000, Fuzzy Sets Syst..

[5]  C. S. Chen,et al.  Design of adaptive load shedding by artificial neural networks , 2005 .

[6]  João Tomé Saraiva,et al.  Generation/transmission power system reliability evaluation by Monte-Carlo simulation assuming a fuzzy load description , 1995 .

[7]  Yacov Y. Haimes,et al.  Multiobjective Decision Making: Theory and Methodology , 1983 .

[8]  Ying-Yi Hong,et al.  Multiobjective Underfrequency Load Shedding in an Autonomous System Using Hierarchical Genetic Algorithms , 2010, IEEE Transactions on Power Delivery.

[9]  V. Terzija,et al.  Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006, IEEE Transactions on Power Systems.

[10]  E.J. Thalassinakis,et al.  A Monte-Carlo simulation method for setting the underfrequency load shedding relays and selecting the spinning reserve policy in autonomous power systems , 2004, IEEE Transactions on Power Systems.

[11]  Gregor Verbic,et al.  Revision of the underfrequency load-shedding scheme of the Slovenian power system , 2007 .

[12]  S. M. Shahidehpour,et al.  Static security in power system operation with fuzzy real load conditions , 1995 .

[13]  S. S. Venkata,et al.  An adaptive approach to load shedding and spinning reserve control during underfrequency conditions , 1996 .