Integration of multimodality imaging and surgical navigation in the management of patients with refractory epilepsy. A pilot study using a new minimally invasive reference and head-fixation system
暂无分享,去创建一个
K. Twerdy | C. Unterhofer | E. Trinka | E. Donnemiller | G. Widmann | R. Bale | E. Trinka | K. Twerdy | T. Gotwald | J. Dobesberger | R. Bauer | G. Walser | E. Donnemiller | I. Unterberger | M. Ortler | M. Ortler | J. Dobesberger | R. Bauer | G. Walser | I. Unterberger | T. Gotwald | G. Widmann | R. Bale | C. Unterhofer
[1] M. Viergever,et al. Medical image matching-a review with classification , 1993, IEEE Engineering in Medicine and Biology Magazine.
[2] H. Schroeder,et al. Neuronavigation and complication rate in epilepsy surgery , 2004, Neurosurgical Review.
[3] Wilhelm Eisner,et al. Multimodality Cranial Image Fusion Using External Markers Applied via a Vacuum Mouthpiece and a Case Report , 2003, Strahlentherapie und Onkologie.
[4] M. Cook,et al. Insertion of depth electrodes with or without subdural grids using frameless stereotactic guidance systems -- technique and outcome , 2002, British journal of neurosurgery.
[5] A. Olivier. Transcortical Selective Amygdalohippocampectomy in Temporal Lobe Epilepsy , 2000, Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques.
[6] Val J Lowe,et al. The Usefulness of Subtraction Ictal SPECT Coregistered to MRI in Single‐ and Dual‐headed SPECT Cameras in Partial Epilepsy , 2002, Epilepsia.
[7] V. Lowe,et al. Triple-technique (MR imaging, single-photon emission CT, and CT) coregistration for image-guided surgical evaluation of patients with intractable epilepsy. , 1999, AJNR. American journal of neuroradiology.
[8] D. Cho,et al. Application of neuronavigator coupled with an operative microscope and electrocorticography in epilepsy surgery. , 2005, Surgical neurology.
[9] C. Wilson,et al. Stereotactic investigation of limbic epilepsy using a multimodal image analysis system. Technical note. , 1990, Journal of neurosurgery.
[10] T. Greitz,et al. Head fixation device for reproducible position alignment in transmission CT and positron emission tomography. , 1981, Journal of computer assisted tomography.
[11] F. San-Galli,et al. Neuronavigation fonctionnelle: Fusion des données de l'IRM fonctionnelle dans un système de neuronavigation , 2004 .
[12] J. Mazziotta,et al. Automated image registration , 1993 .
[13] Theodore H Schwartz,et al. Frameless stereotactic placement of depth electrodes in epilepsy surgery. , 2005, Journal of neurosurgery.
[14] [Image-guided surgery for epilepsy]. , 1997, No shinkei geka. Neurological surgery.
[15] L. Cinotti,et al. Extraction of epileptogenic foci from PET and SPECT images by fuzzy modeling and data fusion , 2003, NeuroImage.
[16] H. Lüders,et al. Presurgical evaluation of epilepsy. , 2001, Brain : a journal of neurology.
[17] K Twerdy,et al. Computer-assisted neurosurgery by using a noninvasive vacuum-affixed dental cast that acts as a reference base: another step toward a unified approach in the treatment of brain tumors. , 2000, Journal of neurosurgery.
[18] R. Cox,et al. Functional MR activation correlated with intraoperative cortical mapping. , 1997, AJNR. American journal of neuroradiology.
[19] H. P. Richter,et al. Cranial Neuronavigation with Direct Integration of 11C Methionine Positron Emission Tomography (PET) Data – Results of a Pilot Study in 32 Surgical Cases , 2002, Acta Neurochirurgica.
[20] Jerome Engel,et al. Outcome with respect to epileptic seizures. , 1993 .
[21] D. Thomas,et al. Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies. Technical note. , 1999, Journal of neurosurgery.
[22] C. Mascott. In vivo accuracy of image guidance performed using optical tracking and optimized registration. , 2006, Journal of neurosurgery.
[23] D. Gadian,et al. Recommendations for Neuroimaging of Patients with Epilepsy , 1997, Epilepsia.
[24] D. Roberts,et al. The evaluation and image-guided surgical treatment of the patient with a medically intractable seizure disorder. , 1996, Neurosurgery clinics of North America.
[25] I. Germano,et al. Frameless stereotaxy for surgery of the epilepsies: preliminary experience. Technical note. , 1994, Journal of neurosurgery.
[26] W. Eisner,et al. Neuroendoscopy based on computer assisted adjustment of the endoscope holder in the laboratory. , 2003, Minimally invasive neurosurgery : MIN.
[27] R. Hogan,et al. Quantitative analysis of cerebral blood flow patterns in mesial temporal lobe epilepsy using composite SISCOM. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[28] W Freysinger,et al. Minimally Invasive Head Holder to Improve the Performance of Frameless Stereotactic Surgery , 1997, The Laryngoscope.
[29] Image-Guided, Frameless Stereotactic Sectioning of the Corpus callosum in Children with Intractable Epilepsy , 2001, Pediatric Neurosurgery.
[30] H. Urbach,et al. SATSCOM—Selective Amobarbital Test Intraarterial SPECT Coregistered to MRI: Description of a Method Assessing Selective Perfusion , 2000, NeuroImage.
[31] Tracy L Faber,et al. Multimodality imaging. , 2003, Seminars in nuclear medicine.
[32] Terence J O'Brien,et al. Subtraction ictal single-photon emission computed tomography coregistered to magnetic resonance imaging in evaluating the need for repeated epilepsy surgery. , 2006, Journal of neurosurgery.
[33] M. Vogele,et al. Vogele-Bale-Hohner mouthpiece: registration device for frameless stereotactic surgery. , 1998, Radiology.
[34] C. Jack,et al. Sensory motor cortex: correlation of presurgical mapping with functional MR imaging and invasive cortical mapping. , 1994, Radiology.
[35] C. Binnie,et al. Pre‐surgical evaluation for epilepsy surgery – European Standards , 2000, European journal of neurology.
[36] R. Maciunas,et al. The application accuracy of stereotactic frames. , 1994, Neurosurgery.
[37] Accuracy and Availability of the Computed Assisted Neurosurgery Navigation System during Epilepsy Surgery , 2000, Stereotactic and Functional Neurosurgery.
[38] Flexibility of head positioning and head fixation provided by a novel system for non-invasive maxillary fixation and frameless stereotaxy: technical note. , 2009, Minimally invasive neurosurgery : MIN.
[39] C. Jack,et al. Subtraction ictal SPECT co‐registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus , 1998, Neurology.
[40] G. Wurm,et al. Evaluation of Neuronavigation in Lesional and Non-Lesional Epilepsy Surgery , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[41] M. Barnes. European Federation of Neurological Societies Task Force , 1997 .
[42] Y. Miyagi,et al. Inferior Temporal Sulcus Approach for Amygdalohippocampectomy Guided by a Laser Beam of Stereotactic Navigator , 2003, Neurosurgery.
[43] Terence J O'Brien,et al. Multimodality image-guided surgery for the treatment of medically refractory epilepsy. , 2004, Journal of neurosurgery.
[44] C. Schaller,et al. Can neuronavigation contribute to standardization of selective amygdalohippocampectomy? , 1997, Stereotactic and functional neurosurgery.
[45] Jerome Engel,et al. Surgical treatment of the epilepsies , 1993 .
[46] John S. Duncan,et al. Guidelines for Neuroimaging Evaluation of Patients with Uncontrolled Epilepsy Considered for Surgery , 1998, Epilepsia.
[47] J. Tsuruda,et al. Integration of preoperative and intraoperative functional brain mapping in a frameless stereotactic environment for lesions near eloquent cortex. Technical note. , 1999, Journal of neurosurgery.
[48] L R Schad,et al. Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors. , 1987, Journal of computer assisted tomography.
[49] G. Widmann,et al. Frameless Stereotactic Cannulation of the Foramen Ovale for Ablative Treatment of Trigeminal Neuralgia , 2006, Neurosurgery.
[50] Scott T. Grafton,et al. Automated image registration: I. General methods and intrasubject, intramodality validation. , 1998, Journal of computer assisted tomography.
[51] W. van Paesschen,et al. Ictal Perfusion Patterns Associated with Single MRI‐Visible Focal Dysplastic Lesions: Implications for the Noninvasive Delineation of the Epileptogenic Zone , 2006, Epilepsia.
[52] Eileen O. Smith,et al. Difference images calculated from ictal and interictal technetium-99m-HMPAO SPECT scans of epilepsy. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[53] W. Eisner,et al. FRAMELESS STEREOTACTIC PLACEMENT OF FORAMEN OVALE ELECTRODES IN PATIENTS WITH DRUG‐REFRACTORY TEMPORAL LOBE EPILEPSY , 2008, Neurosurgery.