Fusion of Electromagnetic Trackers to Improve Needle Deflection Estimation: Simulation Study

We present a needle deflection estimation method to anticipate needle bending during insertion into deformable tissue. Using limited additional sensory information, our approach reduces the estimation error caused by uncertainties inherent in the conventional needle deflection estimation methods. We use Kalman filters to combine a kinematic needle deflection model with the position measurements of the base and the tip of the needle taken by electromagnetic (EM) trackers. One EM tracker is installed on the needle base and estimates the needle tip position indirectly using the kinematic needle deflection model. Another EM tracker is installed on the needle tip and estimates the needle tip position through direct, but noisy measurements. Kalman filters are then employed to fuse these two estimates in real time and provide a reliable estimate of the needle tip position, with reduced variance in the estimation error. We implemented this method to compensate for needle deflection during simulated needle insertions and performed sensitivity analysis for various conditions. At an insertion depth of 150 mm, we observed needle tip estimation error reductions in the range of 28% (from 1.8 to 1.3 mm) to 74% (from 4.8 to 1.2 mm), which demonstrates the effectiveness of our method, offering a clinically practical solution.

[1]  Gregory S. Chirikjian,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[2]  Ole Vegard Solberg,et al.  Navigated laparoscopic ultrasound in abdominal soft tissue surgery: technological overview and perspectives , 2012, International Journal of Computer Assisted Radiology and Surgery.

[3]  T. Podder,et al.  In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy. , 2006, Medical physics.

[4]  Septimiu E. Salcudean,et al.  Needle steering and motion planning in soft tissues , 2005, IEEE Transactions on Biomedical Engineering.

[5]  Thomas Langø,et al.  Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting. , 2012, Medical physics.

[6]  Keyvan Hashtrudi-Zaad,et al.  Development of a dynamic model for bevel-tip flexible needle insertion into soft tissues , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  Toshikatsu Washio,et al.  A Model for Relations between Needle Deflection, Force, and Thickness on Needle Penetration , 2001, MICCAI.

[8]  Rajnikant V. Patel,et al.  An analytical model for deflection of flexible needles during needle insertion , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[9]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[10]  Carl S McGill,et al.  Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy. , 2012, Medical physics.

[11]  D. Simon Optimal State Estimation: Kalman, H Infinity, and Nonlinear Approaches , 2006 .

[12]  D. Minhas,et al.  Modeling of Needle Steering via Duty-Cycled Spinning , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[14]  Daniel Glozman,et al.  Image-Guided Robotic Flexible Needle Steering , 2007, IEEE Transactions on Robotics.

[15]  Allison M. Okamura,et al.  Behavior of Tip-Steerable Needles in Ex Vivo and In Vivo Tissue , 2012, IEEE Transactions on Biomedical Engineering.

[16]  S. Misra,et al.  Macroscopic and microscopic observations of needle insertion into gels , 2012, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[17]  S. Misra,et al.  Mechanics-based model for predicting in-plane needle deflection with multiple bends , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[18]  Gregory S. Chirikjian,et al.  Kinematic state estimation and motion planning for stochastic nonholonomic systems using the exponential map , 2008, Robotica.

[19]  D. Downey,et al.  Brachytherapy needle deflection evaluation and correction. , 2005, Medical physics.

[20]  Septimiu E. Salcudean,et al.  Needle insertion modeling and simulation , 2003, IEEE Trans. Robotics Autom..

[21]  Gabor Fichtinger,et al.  Surgical motion characterization in simulated needle insertion procedures , 2012, Medical Imaging.

[22]  Orcun Goksel,et al.  Modeling and simulation of flexible needles. , 2009, Medical engineering & physics.

[23]  Gabor Fichtinger,et al.  A new scheme for curved needle segmentation in three-dimensional ultrasound images , 2009, 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[24]  Jin Seob Kim,et al.  Diffusion-Based Motion Planning for a Nonholonomic Flexible Needle Model , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[25]  A M Franz,et al.  Standardized assessment of new electromagnetic field generators in an interventional radiology setting. , 2012, Medical physics.

[26]  Georg Eggers,et al.  Accuracy assessment for navigated maxillo-facial surgery using an electromagnetic tracking device. , 2012, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[27]  Yan Yu,et al.  An improved needle steering model with online parameter estimator , 2006, International Journal of Computer Assisted Radiology and Surgery.

[28]  Keck Voon Ling,et al.  High Frequency Translational Oscillation & Rotational Drilling of the Needle in Reducing Target Movement , 2005, 2005 International Symposium on Computational Intelligence in Robotics and Automation.

[29]  Peter Kazanzides,et al.  Multisensor Data Fusion in an Integrated Tracking System for Endoscopic Surgery , 2012, IEEE Transactions on Information Technology in Biomedicine.

[30]  Gregory S. Chirikjian,et al.  Estimation of model parameters for steerable needles , 2010, 2010 IEEE International Conference on Robotics and Automation.

[31]  Gabor Fichtinger,et al.  Needle deflection estimation using fusion of electromagnetic trackers , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.