Origin of peak asymmetry and the effect of temperature on solute retention in enantiomer separations on imprinted chiral stationary phases

Abstract In enantiomer separations of d - and l -phenylalanine anlilide ( d,l -PA) on l -PA-imprinted chiral stationary phases (CSPs), the use of an aqueous buffer-organic solvent mixture as mobile phase resulted in improved column efficiency compared with what has previously been observed using mobile phases containing acetic acid as modifier. The dependence of the chromatographic parameters on flow-rate and sample load was studied. A strong dependence of the asymmetry factor ( A s ) of the l -form on sample load and a weak dependence on flow-rate indicate that the non-linear adsorption isotherm is the main reason for the broad peaks observed in this system. Depending on the method used for the preparation of the materials, different shapes of the plots of retention and selectivity versus sample load were obtained, indicating differences in the site distribution between the polymers. A slow mass transfer was still present but this was in agreement with results from other ion-exchange separations or separations using large porous particles. The band widths of both enantiomers showed a similar dependence on flow-rate and temperature, which is in contrast to earlier reports on imprinted polymers using reversible covalent bonding in the chromatographic separation. As expected from these results, the separation factor (α) and the capacity factor ( k ′) showed no or only a weak dependence on flow-rate. In a study of the effect of temperature on retention and selectivity, linear Van 't Hoff plots were obtained giving ΔH and ΔS ′ values (binding of d - or l -PA, absolute values for the d -form and apparent values for the l -form) and ΔΔH app and ΔΔS app values (differential binding of d,l -PA) that showed an exothermic process. Changing the mobile phase pH from 7 to 4 resulted in an increase, mainly in ΔS ′ and ΔΔS app . Using an acetic acid-containing mobile phase mixture, an endothermic process was observed with positive ΔH , ΔS , ΔΔH app and ΔΔS app values. The results were interpreted in terms of extensive solvation of the solute ammonium groups, the effect being most pronounced in the acetic acid-containing mobile phase.

[1]  C. Horváth,et al.  Mobile phase effects in reversed-phase chromatography : III. Changes in conformation and retention of oligo- (ethylene glycol) derivatives with temperature and eluent composition , 1979 .

[2]  G. Guiochon,et al.  Chromatographic band profiles and band separation of enantiomers at high concentration , 1990 .

[3]  B. Sellergren,et al.  Molecular imprinting of amino acid derivatives in macroporous polymers , 1985 .

[4]  L. Snyder,et al.  A simplified description of HPLC separation under overload conditions. A synthesis and extension of two recent approaches , 1987 .

[5]  Klaus Mosbach,et al.  Highly enantioselective and substrate-selective polymers obtained by molecular imprinting utilizing noncovalent interactions. NMR and chromatographic studies on the nature of recognition , 1988 .

[6]  B. Sellergren,et al.  Chiral ion-exchange chromatography. Correlation between solute retention and a theoretical ion-exchange model using imprinted polymers. , 1993, Journal of chromatography. A.

[7]  B. Sellergren,et al.  Discrimination between amino acid amide conformers by imprinted polymers , 1989 .

[8]  John W. Dolan,et al.  Introduction to modern liquid chromatography , 1974 .

[9]  J. Knox,et al.  Framework for maximizing throughput in preparative liquid chromatography , 1986 .

[10]  C. Horváth,et al.  Mobile phase effects in reversed-phase chromatography : II. Acidic amine phosphate buffers as eluents , 1979 .

[11]  R. Rosset,et al.  Dependence of HETP upon resin particle size and solution flow-rate in high-speed ion-exchange chromatography , 1973 .

[12]  S. Ahuja Chiral separations by liquid chromatography , 1991 .

[13]  B. Sellergren,et al.  Influence of polymer morphology on the ability of imprinted network polymers to resolve enantiomers , 1993 .

[14]  C. Horváth,et al.  Surface silanols in silica-bonded hydrocarbonaceous stationary phases , 1981 .

[15]  Kenneth J. Shea,et al.  Polymer complements to nucleotide bases. Selective binding of adenine derivatives to imprinted polymers , 1993 .

[16]  G. Wulff,et al.  Preparation of chromatographic sorbents with chiral cavities for racemic resolution , 1978 .

[17]  H. Engelhardt High performance liquid chromatography , 1997 .

[18]  J. F. Liebman,et al.  Molecular structure and energetics , 1986 .

[19]  C. Horváth,et al.  Mobile phase effects in reversed-phase chromatography : I. Concomitant dependence of retention on column temperature eluent composition , 1979 .

[20]  J. Knox,et al.  The performance of packings in high-speed liquid chromatography , 1973 .

[21]  F. Vernon Polarity of polyester stationary phases , 1978 .

[22]  Jan Åke Jönsson,et al.  Chromatographic theory and basic principles , 1989 .

[23]  W. H. Pirkle Unusual effect of temperature on the retention of enantiomers on a chiral column , 1991 .

[24]  F. Erni,et al.  Chiral recognition and enantiomeric resolution based on host-guest complexation with crown ethers in capillary zone electrophoresis , 1992 .