Estimating dose delivery accuracy in stereotactic body radiation therapy: a review of in-vivo measurement methods.

Stereotactic body radiation therapy (SBRT) has been recognized as a standard treatment option for many anatomical sites. Sophisticated radiation therapy techniques have been developed for carrying out these treatments and new quality assurance (QA) programs are therefore required to guarantee high geometrical and dosimetric accuracy. This paper focuses on recent advances on in-vivo measurements methods (IVM) for SBRT treatment. More specifically, all of the online QA methods for estimating the effective dose delivered to patients were compared. Determining the optimal IVM for performing SBRT treatments would reduce the risk of errors that could jeopardize treatment outcome. A total of 89 papers were included. The papers were subdivided into the following topics: point dosimeters (PD), transmission detectors (TD), log file analysis (LFA), electronic portal imaging device dosimetry (EPID), dose accumulation methods (DAM). The detectability capability of the main IVM detectors/devices were evaluated. All of the systems have some limitations: PD has no spatial data, EPID has limited sensitivity towards set-up errors and intra-fraction motion in some anatomical sites, TD is insensitive towards patient related errors, LFA is not an independent measure, DAMs are not always based on measures. In order to minimize errors in SBRT dose delivery, we recommend using synergic combinations of two or more of the systems described in our review: on-line tumor position and patient information should be combined with MLC position and linac output detection accuracy. In this way the effects of SBRT dose delivery errors will be reduced.

[1]  Savino Cilla,et al.  A National project for in vivo dosimetry procedures in radiotherapy: First results , 2012 .

[2]  P. Haraldsson,et al.  In vivo dose verification of IMRT treated head and neck cancer patients , 2005, Acta oncologica.

[3]  Sasa Mutic,et al.  Quality control quantification (QCQ): a tool to measure the value of quality control checks in radiation oncology. , 2012, International journal of radiation oncology, biology, physics.

[4]  Marcel van Herk,et al.  Impact of daily anatomical changes on EPID-based in vivo dosimetry of VMAT treatments of head-and-neck cancer. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  Rodney J. Ellis,et al.  Real‐time in vivo dosimetry for SBRT prostate treatment using plastic scintillating dosimetry embedded in a rectal balloon: a case study , 2016, Journal of applied clinical medical physics.

[6]  Savino Cilla,et al.  Treatment planning for spinal radiosurgery , 2018, Strahlentherapie und Onkologie.

[7]  B Mijnheer,et al.  Error detection during VMAT delivery using EPID-based 3D transit dosimetry. , 2018, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[8]  Matthias Guckenberger,et al.  ESTRO ACROP consensus guideline on implementation and practice of stereotactic body radiotherapy for peripherally located early stage non-small cell lung cancer. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Sonja Dieterich,et al.  Can a commercially available EPID dosimetry system detect small daily patient setup errors for cranial IMRT/SRS? , 2017, Practical radiation oncology.

[10]  P. François,et al.  In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams. , 2011, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[11]  Michel Rouzaud,et al.  In vivo quality assurance of volumetric modulated arc therapy for ano-rectal cancer with thermoluminescent dosimetry and image-guidance. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  Larry A DeWerd,et al.  AAPM TG 191 Clinical Use of Luminescent Dosimeters: TLDs and OSLDs. , 2020, Medical physics.

[13]  Gokhan Ozyigit,et al.  Feasibility study of an electronic portal imaging based in vivo dose verification system for prostate stereotactic body radiotherapy. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[14]  Mitsuhiro Nakamura,et al.  Monitoring of mechanical errors and their dosimetric impact throughout the course of non-coplanar continuous volumetric-modulated arc therapy , 2018, Radiation oncology.

[15]  Jan-Jakob Sonke,et al.  A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments. , 2009, Medical physics.

[16]  Nikos Papanikolaou,et al.  Investigation of error detection capabilities of phantom, EPID and MLC log file based IMRT QA methods , 2017, Journal of applied clinical medical physics.

[17]  Kai Yang,et al.  A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery. , 2012, Medical physics.

[18]  T Kron,et al.  Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[19]  A Fidanzio,et al.  EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[20]  A Rea,et al.  In vivo dosimetry with optically stimulated luminescent dosimeters for conformal and intensity-modulated radiation therapy: A 2-year multicenter cohort study. , 2017, Practical radiation oncology.

[21]  Cristina Garibaldi,et al.  A national survey on technology and quality assurance for stereotactic body radiation therapy. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[22]  Todsaporn Fuangrod,et al.  First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions. , 2015, International journal of radiation oncology, biology, physics.

[23]  C. Thieke,et al.  DAVID—a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques , 2006, Physics in medicine and biology.

[24]  Sonja Wegener,et al.  Sensitivity of the IQM transmission detector to errors of VMAT plans , 2018, Medical physics.

[25]  Wendel Dean Renner,et al.  A method for deconvolution of integrated electronic portal images to obtain incident fluence for dose reconstruction , 2005, Journal of applied clinical medical physics.

[26]  Takeshi Ono,et al.  Validation of a method for in vivo 3D dose reconstruction in SBRT using a new transmission detector , 2017, Journal of applied clinical medical physics.

[27]  Eric Van Uytven,et al.  Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy-Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device. , 2017, International journal of radiation oncology, biology, physics.

[28]  K. Younge,et al.  Practical implementation of failure mode and effects analysis for safety and efficiency in stereotactic radiosurgery. , 2015, International journal of radiation oncology, biology, physics.

[29]  E. Ford,et al.  Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations. , 2015, Medical physics.

[30]  Tom Depuydt,et al.  Stereotactic body radiation therapy with optional focal lesion ablative microboost in prostate cancer: Topical review and multicenter consensus. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  Per Rugaard Poulsen,et al.  Respiratory gating based on internal electromagnetic motion monitoring during stereotactic liver radiation therapy: First results , 2015, Acta oncologica.

[32]  Peter B Greer,et al.  Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm. , 2015, Medical physics.

[33]  Paul J Keall,et al.  The first clinical implementation of real-time image-guided adaptive radiotherapy using a standard linear accelerator. , 2018, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[34]  Cai Grau,et al.  A Prospective Cohort Study of Gated Stereotactic Liver Radiation Therapy Using Continuous Internal Electromagnetic Motion Monitoring. , 2018, International journal of radiation oncology, biology, physics.

[35]  Cedric X. Yu,et al.  A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions. , 2003, Medical physics.

[36]  B M C McCurdy,et al.  Model-based prediction of portal dose images during patient treatment. , 2013, Medical physics.

[37]  Anatoly B. Rosenfeld,et al.  In vivo endorectal dosimetry of prostate tomotherapy using dual MOSkin detectors , 2015, Journal of applied clinical medical physics.

[38]  Eric C Ford,et al.  A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy. , 2015, Medical physics.

[39]  C. Moustakis,et al.  A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry , 2020, Strahlentherapie und Onkologie.

[40]  P M McCowan,et al.  An in vivo dose verification method for SBRT-VMAT delivery using the EPID. , 2015, Medical physics.

[41]  Young-Bin Cho,et al.  A method for online verification of adapted fields using an independent dose monitor. , 2013, Medical physics.

[42]  Pietro Mancosu,et al.  Multi-institutional application of Failure Mode and Effects Analysis (FMEA) to CyberKnife Stereotactic Body Radiation Therapy (SBRT) , 2015, Radiation Oncology.

[43]  Adam C. Riegel,et al.  Dosimetric impact of placement errors in optically stimulated luminescent in vivo dosimetry in radiotherapy , 2019, Physics and imaging in radiation oncology.

[44]  Sara Bresciani,et al.  Comparison of two different EPID-based solutions performing pretreatment quality assurance: 2D portal dosimetry versus 3D forward projection method. , 2018, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[45]  M. Petasecca,et al.  Characterization of a novel two dimensional diode array the "magic plate" as a radiation detector for radiation therapy treatment. , 2012, Medical physics.

[46]  Duncan B. McLaren,et al.  EPID‐based in vivo dosimetry using Dosimetry Check™: Overview and clinical experience in a 5‐yr study including breast, lung, prostate, and head and neck cancer patients , 2018, Journal of applied clinical medical physics.

[47]  Philippe Lambin,et al.  The next step in patient-specific QA: 3D dose verification of conformal and intensity-modulated RT based on EPID dosimetry and Monte Carlo dose calculations. , 2008, Radiotherapy and Oncology.

[48]  J Balosso,et al.  Radiotherapy quality assurance by individualized in vivo dosimetry: state of the art. , 2009, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[49]  C. Agnew,et al.  Correlation of phantom‐based and log file patient‐specific QA with complexity scores for VMAT , 2014, Journal of applied clinical medical physics.

[50]  Peter Ziegenhein,et al.  Online dose reconstruction for tracked volumetric arc therapy: Real‐time implementation and offline quality assurance for prostate SBRT , 2017, Medical physics.

[51]  M van Herk,et al.  Catching errors with in vivo EPID dosimetry. , 2010, Medical physics.

[52]  Elena Gallio,et al.  Clinical evaluation of a transmission detector system and comparison with a homogeneous 3D phantom dosimeter. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[53]  D C Weber,et al.  Assessment of target dose delivery in anal cancer using in vivo thermoluminescent dosimetry. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[54]  Marcel van Herk,et al.  Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry. , 2015, Practical radiation oncology.

[55]  E. Schreibmann,et al.  Patient-specific quality assurance method for VMAT treatment delivery. , 2009, Medical physics.

[56]  Peter Ziegenhein,et al.  Real‐time 4D dose reconstruction for tracked dynamic MLC deliveries for lung SBRT , 2016, Medical physics.

[57]  James L Bedford,et al.  Quality of treatment plans and accuracy of in vivo portal dosimetry in hybrid intensity-modulated radiation therapy and volumetric modulated arc therapy for prostate cancer. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[58]  R Calandrino,et al.  Quality assurance by systematic in vivo dosimetry: results on a large cohort of patients. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[59]  Inhwan Yeo,et al.  Four-dimensional dose reconstruction through in vivo phase matching of cine images of electronic portal imaging device. , 2016, Medical physics.

[60]  M Glitzner,et al.  On-line MR imaging for dose validation of abdominal radiotherapy , 2015, Physics in medicine and biology.

[61]  D. Jaffray,et al.  An integral quality monitoring system for real-time verification of intensity modulated radiation therapy. , 2009, Medical physics.

[62]  Jean M. Moran,et al.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis , 2002, Journal of applied clinical medical physics.

[63]  Jan-Jakob Sonke,et al.  Tumor Trailing for Liver SBRT on the MR-Linac. , 2019, International journal of radiation oncology, biology, physics.

[64]  P. François,et al.  EPID based in vivo dosimetry system: clinical experience and results , 2016, Journal of applied clinical medical physics.

[65]  Chang Heon Choi,et al.  Validation of new transmission detector transmission factors for online dosimetry: an experimental study , 2018, Radiation oncology.

[66]  David S Followill,et al.  Institutional patient-specific IMRT QA does not predict unacceptable plan delivery. , 2014, International journal of radiation oncology, biology, physics.

[67]  Ben Mijnheer,et al.  Site‐specific alert criteria to detect patient‐related errors with 3D EPID transit dosimetry , 2018, Medical physics.

[68]  Elena Villaggi,et al.  SBRT planning for spinal metastasis: indications from a large multicentric study , 2018, Strahlentherapie und Onkologie.

[69]  Lu Wang,et al.  4D patient dose reconstruction using online measured EPID cine images for lung SBRT treatment validation. , 2012, Medical physics.

[70]  A. Ralston,et al.  In vivo and phantom measurements versus Eclipse TPS prediction of near surface dose for SBRT treatments , 2014 .

[71]  A. Owrangi,et al.  Technical Report: Evaluation of peripheral dose for flattening filter free photon beams. , 2016, Medical physics.

[72]  Esben Worm,et al.  First online real‐time evaluation of motion‐induced 4D dose errors during radiotherapy delivery , 2018, Medical physics.

[73]  H. Woodruff,et al.  Investigation of a real-time EPID-based patient dose monitoring safety system using site-specific control limits , 2016, Radiation oncology.

[74]  Oliver Blanck,et al.  ICRU report 91 on prescribing, recording, and reporting of stereotactic treatments with small photon beams , 2019, Strahlentherapie und Onkologie.

[75]  Minsong Cao,et al.  Stereotactic MRI-guided Adaptive Radiation Therapy (SMART) for Locally Advanced Pancreatic Cancer: A Promising Approach , 2018, Cureus.

[76]  Jan-Jakob Sonke,et al.  In aqua vivo EPID dosimetry. , 2011, Medical physics.

[77]  Marcel van Herk,et al.  Online 3D EPID-based dose verification: Proof of concept. , 2016, Medical physics.

[78]  Volker Steil,et al.  Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies , 2010, Physics in medicine and biology.

[79]  Taoran Li,et al.  Diode‐based transmission detector for IMRT delivery monitoring: a validation study , 2016, Journal of applied clinical medical physics.

[80]  Krishni Wijesooriya,et al.  A clinically observed discrepancy between image-based and log-based MLC positions. , 2016, Medical physics.

[81]  Peter M McCowan,et al.  In vivo dosimetry for lung radiotherapy including SBRT. , 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[82]  Vincenzo Valentini,et al.  Online adaptive magnetic resonance guided radiotherapy for pancreatic cancer: state of the art, pearls and pitfalls , 2019, Radiation Oncology.

[83]  I Olaciregui-Ruiz,et al.  A back-projection algorithm in the presence of an extra attenuating medium: towards EPID dosimetry for the MR-Linac. , 2017, Physics in medicine and biology.

[84]  Audrey H. Zhuang,et al.  Sensitivity study of an automated system for daily patient QA using EPID exit dose images , 2018, Journal of applied clinical medical physics.

[85]  Marco Esposito,et al.  Characterization of EPID software for VMAT transit dosimetry , 2018, Australasian Physical & Engineering Sciences in Medicine.

[86]  Dan Cao,et al.  Matched-pair comparisons of stereotactic body radiotherapy (SBRT) versus surgery for the treatment of early stage non-small cell lung cancer: a systematic review and meta-analysis. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[87]  Iban Torres-Xirau,et al.  2D EPID dosimetry for an MR-linac: proof of concept. , 2019, Medical physics.

[88]  S Nill,et al.  Assessment of MLC tracking performance during hypofractionated prostate radiotherapy using real-time dose reconstruction , 2016, Physics in medicine and biology.

[89]  Savino Cilla,et al.  In vivo dosimetry by an aSi-based EPID. , 2006, Medical physics.

[90]  Todsaporn Fuangrod,et al.  A method for evaluating treatment quality using in vivo EPID dosimetry and statistical process control in radiation therapy. , 2017, International journal of health care quality assurance.

[91]  Per Rugaard Poulsen,et al.  Kilovoltage intrafraction motion monitoring and target dose reconstruction for stereotactic volumetric modulated arc therapy of tumors in the liver. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[92]  B. Poppe,et al.  Clinical performance of a transmission detector array for the permanent supervision of IMRT deliveries. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[93]  J. Seong,et al.  Clinical feasibility and efficacy of stereotactic body radiotherapy for hepatocellular carcinoma: A systematic review and meta-analysis of observational studies. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[94]  L. Beaulieu,et al.  Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor. , 2011, Medical physics.

[95]  Eric C Ford,et al.  Evaluation of safety in a radiation oncology setting using failure mode and effects analysis. , 2009, International journal of radiation oncology, biology, physics.

[96]  M. Schell,et al.  Stereotactic Body Radiation for the Spine: A Review , 2013, American journal of clinical oncology.

[97]  M. Scorsetti,et al.  Applying failure mode effects and criticality analysis in radiotherapy: lessons learned and perspectives of enhancement. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[98]  Arjun Sahgal,et al.  International consensus recommendations for target volume delineation specific to sacral metastases and spinal stereotactic body radiation therapy (SBRT). , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[99]  Savino Cilla,et al.  Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy , 2019, Journal of applied clinical medical physics.

[100]  S Nill,et al.  Adaptive Radiotherapy Enabled by MRI Guidance. , 2018, Clinical oncology (Royal College of Radiologists (Great Britain)).

[101]  K Ricketts,et al.  Implementation and evaluation of a transit dosimetry system for treatment verification. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[102]  Anatoly Rosenfeld,et al.  Real-time in vivo rectal wall dosimetry using MOSkin detectors during linac based stereotactic radiotherapy with rectal displacement , 2017, Radiation oncology.

[103]  Xiaowei Liu,et al.  Investigating the effectiveness of monitoring relevant variations during IMRT and VMAT treatments by EPID-based 3D in vivo verification performed using planning CTs , 2019, PloS one.

[104]  B. McCurdy,et al.  The influence of a novel transmission detector on 6 MV x-ray beam characteristics. , 2009, Physics in medicine and biology.

[105]  Ping Xia,et al.  Tolerance limits and methodologies for IMRT measurement‐based verification QA , 2018, Medical physics.

[106]  Alain Noel,et al.  Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry , 1995 .

[107]  Philippe Lambin,et al.  Routine individualised patient dosimetry using electronic portal imaging devices. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[108]  Cinzia Talamonti,et al.  Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms , 2017, Strahlentherapie und Onkologie.

[109]  Zdenka Kuncic,et al.  Kilovoltage intrafraction monitoring for prostate intensity modulated arc therapy: first clinical results. , 2012, International journal of radiation oncology, biology, physics.

[110]  Elisabetta Cagni,et al.  Multicentre treatment planning inter-comparison in a national context: The liver stereotactic ablative radiotherapy case. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[111]  P. Higgins,et al.  In vivo diode dosimetry for routine quality assurance in IMRT. , 2003, Medical physics.