Low-Frequency Resonance Suppression of a Dual-Active-Bridge DC/DC converter Enabled DC Microgrid

In this paper, the small signal stability issue of a dual-active-bridge (DAB) converter enabled dc microgrid is addressed. The derived impedance characteristic of the source DAB converter reveal that the stability of this dc grid is decided by the low-frequency terminal behaviors of integrated units, which is different from that of dc microgrids powered by other types of source converters. At this low-frequency range, the tightly regulated load converter exhibits constant power load behavior even with a low control bandwidth, which degrades system stability by exacerbating interactions among power converters. Moreover, the deployed power management strategy requires operating mode transitions of energy storage units to achieve intelligent power flow, which further complicates system impedance characteristics. To analyze and solve these issues, the systematic impedance models of this dc grid under different operation modes are derived and analyzed. Reduced-order low-frequency models are simplified from the systematic impedance model to unravel the resonance mechanism. In addition, an impedance shaping technique is proposed to eliminate the resonant path in the reduced-order low-frequency models, therefore the dc grid stability has been improved. Finally, a hardware-in-the-loop application with OPAL-RT real-time simulators is used to validate proposed methods.

[1]  Juan C. Vasquez,et al.  Tertiary and Secondary Control Levels for Efficiency Optimization and System Damping in Droop Controlled DC–DC Converters , 2015, IEEE Transactions on Smart Grid.

[2]  Marta Molinas,et al.  Degree of Influence of System States Transition on the Stability of a DC Microgrid , 2014, IEEE Transactions on Smart Grid.

[3]  Josep M. Guerrero,et al.  Power Oscillations Damping in DC Microgrids , 2016, IEEE Transactions on Energy Conversion.

[4]  Amit Kumar Tamang Coordinated Charging of Plug-in Hybrid Electric Vehicles to Minimize Distribution System Losses , 2013 .

[5]  Fred C. Lee,et al.  Impedance specifications for stable DC distributed power systems , 2002 .

[6]  Jinjun Liu,et al.  Stability Issues of $Z + Z$ Type Cascade System in Hybrid Energy Storage System (HESS) , 2014, IEEE Transactions on Power Electronics.

[7]  Dirk Uwe Sauer,et al.  Analysis of battery current microcycles in autonomous renewable energy systems , 2002 .

[8]  Dushan Boroyevich,et al.  Future electronic power distribution systems a contemplative view , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[9]  Fei Wang,et al.  Design and Demonstration of a 3.6-kV–120-V/10-kVA Solid-State Transformer for Smart Grid Application , 2014, IEEE Transactions on Power Electronics.

[10]  Marta Molinas,et al.  Large Signal Stability Analysis at the Common Coupling Point of a DC Microgrid: A Grid Impedance Estimation Approach Based on a Recursive Method , 2015, IEEE Transactions on Energy Conversion.

[11]  Huang-Jen Chiu,et al.  LED Backlight Driving System for Large-Scale LCD Panels , 2007, IEEE Transactions on Industrial Electronics.

[12]  Yasser Abdel-Rady I. Mohamed,et al.  Linear Active Stabilization of Converter-Dominated DC Microgrids , 2012, IEEE Transactions on Smart Grid.

[13]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[14]  Antonello Monti,et al.  Why ideal constant power loads are not the worst case condition from a control standpoint , 2015 .

[15]  Lingling Fan,et al.  DC Impedance-Model-Based Resonance Analysis of a VSC–HVDC System , 2015, IEEE Transactions on Power Delivery.

[16]  Xinbo Ruan,et al.  Impedance-Based Local Stability Criterion for DC Distributed Power Systems , 2015, IEEE Transactions on Circuits and Systems I: Regular Papers.

[17]  Yinglai Xia,et al.  Influence of bi-directional power flow on impedance and stability of cascaded systems , 2014, IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society.

[18]  D. Boroyevich,et al.  Modeling, control and stability analysis of a PEBB based DC DPS , 1999 .

[19]  Y. M. Lai,et al.  Systematic Derivation of a Family of Output-Impedance Shaping Methods for Power Converters—A Case Study Using Fuel Cell-Battery-Powered Single-Phase Inverter System , 2015, IEEE Transactions on Power Electronics.

[20]  Alex Q. Huang,et al.  Power Management for DC Microgrid Enabled by Solid-State Transformer , 2014, IEEE Transactions on Smart Grid.

[21]  Fred C. Lee,et al.  Stability margin monitoring for DC distributed power systems via perturbation approaches , 2003 .

[22]  Hui Li,et al.  Impedance modeling and verification of a dual active bridge (DAB) DC/DC converter enabled DC microgrid in FREEDM system , 2016, 2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia).

[23]  Juan C. Vasquez,et al.  Stability Enhancement Based on Virtual Impedance for DC Microgrids With Constant Power Loads , 2015, IEEE Transactions on Smart Grid.

[24]  Frede Blaabjerg,et al.  An impedance-based stability analysis method for paralleled voltage source converters , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[25]  Javier Sebastian,et al.  Different purpose design strategies and techniques to improve the performance of a Dual Active Bridge with phase-shift control , 2014, COMPEL 2014.

[26]  Juan C. Vasquez,et al.  DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues , 2016, IEEE Transactions on Power Electronics.

[27]  Hui Li,et al.  High-Frequency Transformer Isolated Bidirectional DC–DC Converter Modules With High Efficiency Over Wide Load Range for 20 kVA Solid-State Transformer , 2011, IEEE Transactions on Power Electronics.

[28]  C. K. Michael Tse,et al.  Direct and Optimal Linear Active Methods for Stabilization of LC Input Filters and DC/DC Converters Under Voltage Mode Control , 2015, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[29]  Hui Li,et al.  A unified Impedance-based Stability Criterion (UIBSC) for paralleled grid-tied inverters using global minor loop gain (GMLG) , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[30]  Reza Ahmadi,et al.  Improving the Performance of a Line Regulating Converter in a Converter-Dominated DC Microgrid System , 2014, IEEE Transactions on Smart Grid.

[31]  Dushan Boroyevich,et al.  Grid-Interface Bidirectional Converter for Residential DC Distribution Systems—Part One: High-Density Two-Stage Topology , 2013, IEEE Transactions on Power Electronics.

[32]  Hui Li,et al.  Stability analysis and improvement of solid state transformer (SST)-paralleled inverters system using negative impedance feedback control , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[33]  B. Nahid-Mobarakeh,et al.  Linear Stabilization of a DC Bus Supplying a Constant Power Load: A General Design Approach , 2010, IEEE Transactions on Power Electronics.

[34]  Thomas J. Overbye,et al.  An Authenticated Control Framework for Distributed Voltage Support on the Smart Grid , 2010, IEEE Transactions on Smart Grid.