Problems in Assessment of Novel Biopotential Front-End with Dry Electrode: A Brief Review

Developers of novel or improved front-end circuits for biopotential recordings using dry electrodes face the challenge of validating their design. Dry electrodes allow more user-friendly and pervasive patient-monitoring, but proof is required that new devices can perform biopotential recording with a quality at least comparable to existing medical devices. Aside from electrical safety requirement recommended by standards and concise circuit requirement, there is not yet a complete validation procedure able to demonstrate improved or even equivalent performance of the new devices. This short review discusses the validation procedures presented in recent, landmark literature and offers interesting issues and hints for a more complete assessment of novel biopotential front-end.

[1]  K. Watanabe,et al.  Wearable electroencephalograph system with preamplified electrodes , 2006, Medical and Biological Engineering and Computing.

[2]  Robert T. Knight,et al.  An active, microfabricated, scalp electrode array for EEG recording , 1996 .

[3]  Gert Cauwenberghs,et al.  Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing , 2011, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[4]  Andre van Schaik,et al.  Wearable dry sensors with bluetooth connection for use in remote patient monitoring systems. , 2010, Studies in health technology and informatics.

[5]  T. D. Clark,et al.  An ultra-low-noise electrical-potential probe for human-body scanning , 2000 .

[6]  R. Granit THE HEART ( Extract from “ Principles and Applications of Bioelectric and Biomagnetic Fields , 2005 .

[7]  André van Schaik,et al.  Giga-Ohm High-Impedance FET Input Amplifiers for Dry Electrode Biosensor Circuits and Systems , 2011 .

[8]  Ramon Pallàs-Areny,et al.  A novel fully differential biopotential amplifier with DC suppression , 2004, IEEE Transactions on Biomedical Engineering.

[9]  Paolo Bifulco,et al.  Towards true unipolar bio-potential recording: a preliminary result for ECG. , 2013, Physiological measurement.

[10]  Rita Paradiso,et al.  A wearable health care system based on knitted integrated sensors , 2005, IEEE Transactions on Information Technology in Biomedicine.

[11]  Carlos H. Muravchik,et al.  Bio-potential amplifier for potential gradient measurements , 2007 .

[12]  Barrett C. Craner,et al.  Design and Development of Medical Electronic Instrumentation , 2005 .

[13]  Maria Romano,et al.  An ultra-high input impedance ECG amplifier for long-term monitoring of athletes , 2010, Medical devices.

[14]  Vojkan Mihajlovic,et al.  To What Extent can Dry and Water-based EEG Electrodes Replace Conductive Gel Ones? - A Steady State Visual Evoked Potential Brain-computer Interface Case Study , 2011, BIODEVICES.

[15]  E.M. Spinelli,et al.  A transconductance driven-right-leg circuit , 1999, IEEE Transactions on Biomedical Engineering.

[16]  James C. Christensen,et al.  Validation of a Dry Electrode System for EEG , 2009 .

[17]  Metin Akay,et al.  Wiley encyclopedia of biomedical engineering , 2006 .

[18]  E. Braunwald Heart Disease: A Textbook of Cardiovascular Medicine , 1992, Annals of Internal Medicine.

[19]  Martin J. Burke,et al.  A micropower dry-electrode ECG preamplifier , 2000, IEEE Transactions on Biomedical Engineering.

[20]  Heinz Jäckel,et al.  A pseudodifferential amplifier for bioelectric events with DC-offset compensation using two-wired amplifying electrodes , 2006, IEEE Transactions on Biomedical Engineering.

[21]  A. Baba,et al.  Measurement of the electrical properties of ungelled ECG electrodes , 2008 .

[22]  John G. Webster,et al.  Reductionl of Interference Due to Common Mode Voltage in Biopotential Amplifiers , 1983, IEEE Transactions on Biomedical Engineering.

[23]  Risto Ilmoniemi,et al.  Wiley Encyclopedia of Biomedical Engineering , 2006 .

[24]  Cedric Assambo,et al.  Low-Frequency Response and the Skin-Electrode Interface in Dry-Electrode Electrocardiography , 2012 .

[25]  T. D. Clark,et al.  Electric potential probes - new directions in the remote sensing of the human body , 2002 .

[26]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[27]  P. Bifulco,et al.  A mobile EEG system with dry electrodes , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[28]  André van Schaik,et al.  Unipolar ECG circuits: Towards more precise cardiac event identification , 2013, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013).

[29]  Felix A. Levinzon,et al.  Ultra-Low-Noise High-Input Impedance Amplifier for Low-Frequency Measurement Applications , 2008, IEEE Transactions on Circuits and Systems I: Regular Papers.

[30]  P. Bifulco,et al.  Mobile biomedical sensing with dry electrodes , 2008, 2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[31]  André van Schaik,et al.  A new EEG recording system for passive dry electrodes , 2010, Clinical Neurophysiology.

[32]  Dobromir Petkov Dobrev,et al.  Bootstrapped two-electrode biosignal amplifier , 2008, Medical & Biological Engineering & Computing.

[33]  Hans-Jurgen Zepernick,et al.  Effect of primary network on performance of spectrum sharing AF relaying , 2012 .

[34]  Ning Wang,et al.  Pregnancy detection and monitoring in cattle via combined foetus electrocardiogram and phonocardiogram signal processing , 2012, BMC Veterinary Research.

[35]  Jean Gotman,et al.  Recommendations Regarding the Requirements and Applications for Long‐term Recordings in Epilepsy , 2007, Epilepsia.

[36]  R. J. Prance,et al.  Biological and medical applications of a new electric field sensor , 2008 .

[37]  C. Grimbergen,et al.  Investigation into the origin of the noise of surface electrodes , 2002, Medical and Biological Engineering and Computing.

[38]  P Bifulco,et al.  Towards true unipolar ECG recording without the Wilson central terminal (preliminary results). , 2013, Physiological measurement.

[39]  Ramon Pallàs-Areny,et al.  AC-coupled front-end for biopotential measurements , 2003, IEEE Transactions on Biomedical Engineering.

[40]  Guideline One: Minimum Technical Requirements for Performing Clinical Electroencephalography , 1986, American journal of electroneurodiagnostic technology.

[41]  P. Libby,et al.  Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine, 2-Volume Set, 9th Edition Expert Consult Premium Edition €“ Enhanced Online Features , 2011 .

[42]  P. Macfarlane,et al.  Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, , 1990, Circulation.

[43]  Juliane Junker,et al.  Medical Instrumentation Application And Design , 2016 .

[44]  Gregory Cohen,et al.  Active electrode design suitable for simultaneous EIT and EEG , 2012 .

[45]  G. Cauwenberghs,et al.  Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[46]  Yu-Te Wang,et al.  A Wearable Mobile Electrocardiogram measurement device with novel dry polymer-based electrodes , 2010, TENCON 2010 - 2010 IEEE Region 10 Conference.