Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”

Background: A truly noninvasive glucose-sensing device could revolutionalize diabetes treatment by leading to improved compliance with recommended glucose levels, thus reducing the long-term complications and cost of diabetes. Herein, we present the technology and evaluate the efficacy of a truly noninvasive device for continuous blood glucose monitoring, the NBM (OrSense Ltd.). Methods: In vitro analysis was used to validate the technology and algorithms. A clinical study was performed to quantify the in vivo performance of the NBM device. A total of 23 patients with type 1 (n = 12) and type 2 (n = 11) diabetes were enrolled in the clinical study and participated in 111 sessions. Accuracy was assessed by comparing NBM data with paired self-monitoring of blood glucose meter readings. Results: In vitro experiments showed a strong correlation between calculated and actual glucose concentrations. The clinical trial produced a total of 1690 paired glucose values (NBM vs reference). In the paired data set, the reference glucose range was 40–496 mg/dl. No systematic bias was found at any of the glucose levels examined (70, 100, 150, and 200 mg/dl). The mean relative absolute difference was 17.2%, and a Clarke error grid analysis showed that 95.5% of the measurements fall within the clinically acceptable A&B regions (zone A, 69.7%; and zone B, 25.7%). Conclusions: This study indicates the potential use of OrSense's NBM device as a noninvasive sensor for continuous blood glucose evaluation. The device was safe and well tolerated.

[1]  S. Wild,et al.  Global prevalence of diabetes: estimates for the year 2000 and projections for 2030. , 2004, Diabetes care.

[2]  Plamen Nikolov,et al.  Economic Costs of Diabetes in the U.S. in 2002 , 2003, Diabetes care.

[3]  Howard Zisser,et al.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. , 2006, Diabetes care.

[4]  M Schetz,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[5]  I. Raz,et al.  Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects. , 2007, Diabetes technology & therapeutics.

[6]  O. Khalil,et al.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. , 2004, Diabetes technology & therapeutics.

[7]  G. W. Small,et al.  Noninvasive glucose sensing. , 2005, Analytical chemistry.

[8]  Aesha Drozdowski,et al.  Standards of medical care in diabetes. , 2004, Diabetes care.

[9]  Diabetes Control Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. Diabetes Control and Complications Trial Research Group. , 1994, The Journal of pediatrics.

[10]  L. D. Shvartsman,et al.  Optical transmission of blood: effect of erythrocyte aggregation , 2003, IEEE Transactions on Biomedical Engineering.

[11]  David B Sacks,et al.  Measurement of circulating glucose concentrations: the time is now for consistency among methods and types of samples. , 2005, Clinical chemistry.

[12]  S. Genuth,et al.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. , 1993, The New England journal of medicine.

[13]  B H Ginsberg,et al.  An overview of minimally invasive technologies. , 1992, Clinical chemistry.

[14]  Richard H Guy,et al.  Noninvasive and minimally invasive methods for transdermal glucose monitoring. , 2005, Diabetes technology & therapeutics.

[15]  P. Böhme,et al.  Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs. , 2003, Diabetes care.

[16]  B. Bistrian,et al.  Intensive insulin therapy in critically ill patients. , 2002, The New England journal of medicine.

[17]  G. Van den Berghe,et al.  Intensive insulin therapy in the medical ICU. , 2006, The New England journal of medicine.

[18]  Disease Management in the Young Diabetic Patient: Glucose Monitoring, Coping Skills, and Treatment Strategies , 2005, Clinical pediatrics.

[19]  M Essenpreis,et al.  The influence of glucose concentration upon the transport of light in tissue-simulating phantoms. , 1995, Physics in medicine and biology.

[20]  D. Klonoff Continuous glucose monitoring: roadmap for 21st century diabetes therapy. , 2005, Diabetes care.