Optimum friction pendulum system for near-fault motions

The analytical seismic response of multi-story buildings isolated by the friction pendulum system (FPS) is investigated under near-fault motions. The superstructure is idealized as a linear shear type flexible building. The governing equations of motion of the isolated structural system are derived and the response of the system to the normal component of six recorded near-fault motions is evaluated by the step-by-step method. The variation of top floor absolute acceleration and sliding displacement of the isolated building is plotted under different system parameters such as superstructure flexibility, isolation period and friction coefficient of the FPS. The comparison of results indicated that for low values of friction coefficient there is significant sliding displacement in the FPS under near-fault motions. In addition, there also exists a particular value of the friction coefficient of FPS for which the top floor absolute acceleration of the building attains the minimum value. Further, the optimum friction coefficient of the FPS is derived for different system parameters under near-fault motions. The criterion selected for optimality is the minimization of both the top floor acceleration and the sliding displacement. The optimum friction coefficient of the FPS is found to be in the range of 0.05 to 0.15 under near-fault motions. In addition, the response of a bridge seismically isolated by the FPS is also investigated and it is found that there exists a particular value of the friction coefficient for which the pier base shear and deck acceleration attain the minimum value under near-fault motions.

[1]  Naser Mostaghel,et al.  Response of sliding structures to harmonic support motion , 1983 .

[2]  Naser Mostaghel,et al.  Response of sliding structures to earthquake support motion , 1983 .

[3]  R. S. Jangid,et al.  A COMPARATIVE STUDY OF PERFORMANCE OF VARIOUS ISOLATION SYSTEMS FOR LIQUID STORAGE TANKS , 2002 .

[4]  Nicos Makris,et al.  RIGIDITY–PLASTICITY–VISCOSITY: CAN ELECTRORHEOLOGICAL DAMPERS PROTECT BASE‐ISOLATED STRUCTURES FROM NEAR‐SOURCE GROUND MOTIONS? , 1997 .

[5]  M. Livolant,et al.  Seismic isolation using sliding-elastomer bearing pads , 1985 .

[6]  Li Xiaoming Optimization of the stochastic response of a bridge isolation system with hysteretic dampers , 1989 .

[7]  R. S. Jangid,et al.  Base isolation for near‐fault motions , 2001 .

[8]  M. Khodaverdian,et al.  Dynamics of resilient‐friction base isolator (R‐FBI) , 1987 .

[9]  Goodarz Ahmadi,et al.  Floor response spectra for base‐isolated multi‐storey structures , 1990 .

[10]  Goodarz Ahmadi,et al.  Comparative study of base isolation systems , 1989 .

[11]  Nicos Makris,et al.  Response of Damped Oscillators to Cycloidal Pulses , 2000 .

[12]  Yeong-Bin Yang,et al.  Response of multi‐degree‐of‐freedom structures with sliding supports , 1990 .

[13]  Marvin W. Halling,et al.  Near-Source Ground Motion and its Effects on Flexible Buildings , 1995 .

[14]  D. Wald,et al.  Response of High-Rise and Base-Isolated Buildings to a Hypothetical Mw 7.0 Blind Thrust Earthquake , 1995, Science.

[15]  T. K. Datta,et al.  Performance of base isolation systems for asymmetric building subject to random excitation , 1995 .

[16]  R. S. Jangid,et al.  EFFECTIVENESS OF ELLIPTICAL ROLLING RODS FOR BASE ISOLATION , 1998 .

[17]  R. S. Jangid SEISMIC RESPONSE OF ISOLATED BRIDGES , 2004 .

[18]  Michael C. Constantinou,et al.  Experimental Study of Friction‐Pendulum Isolation System , 1991 .

[19]  R. S. Jangid,et al.  Seismic response of isolated bridges with soil-structure interaction , 2003 .

[20]  Michael C. Constantinou,et al.  Verification of friction model of teflon bearings under triaxial load , 1993 .

[21]  Wei-Hsin Liao,et al.  SEISMIC RESPONSE ANALYSIS OF BRIDGES ISOLATED WITH FRICTION PENDULUM BEARINGS , 1998 .

[22]  Ahmed Ghobarah,et al.  SEISMIC PERFORMANCE OF HIGHWAY BRIDGES , 1988 .

[23]  Stephen A. Mahin,et al.  A Simple Pendulum Technique for Achieving Seismic Isolation , 1990 .