Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changes.

Long-term electrical impedance measurements are affected by specific errors. Electrode failure, changes in its impedance due to aging, and postural changes are among the most important. We analyse errors due to electrode replacement and body postural changes. Electrode replacement errors can cause impedance changes up to 5% of basal value. This is one of the most important factors in data reproducibility. Body postural changes also contribute to impedance variations. We have proposed the use of a reference position to carry out impedance measurements as the one that shows the smallest impedance sensitivity to postural changes. In general, we observed that this is achieved with arms and legs slightly separated from the body. We propose the use of a ratio of impedance at two different frequencies to discern the origin of impedance changes, whether from physiological phenomena or postural errors.

[1]  H C Lukaski,et al.  Methods for the assessment of human body composition: traditional and new. , 1987, The American journal of clinical nutrition.

[2]  J. Rosell,et al.  Skin impedance from 1 Hz to 1 MHz , 1988, IEEE Transactions on Biomedical Engineering.

[3]  D. Schoeller,et al.  Determination of body fluids by the impedance technique , 1989, IEEE Engineering in Medicine and Biology Magazine.

[4]  J. Webster,et al.  The electrode system in impedance-based ventilation measurement , 1992, IEEE Transactions on Biomedical Engineering.

[5]  H. Kanai,et al.  Electrical measurement of fluid distribution in legs and arms. , 1987, Medical progress through technology.

[6]  R. Patterson,et al.  Body fluid determinations using multiple impedance measurements , 1989, IEEE Engineering in Medicine and Biology Magazine.

[7]  S. B. Raza,et al.  Impedance cardiography using band and regional electrodes in supine, sitting, and during exercise , 1991, IEEE Transactions on Biomedical Engineering.

[8]  W E Thornton,et al.  Space shuttle inflight and postflight fluid shifts measured by leg volume changes. , 1987, Aviation, space, and environmental medicine.

[9]  P J Riu,et al.  A broadband system for multifrequency static imaging in electrical impedance tomography. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.