Extended sagittal saw cut significantly reduces fracture load in cementless unicompartmental knee arthroplasty compared to cemented tibia plateaus: an experimental cadaver study

PurposePeriprosthetic tibial plateau fractures represent a rare but serious complication in unicompartmental knee arthroplasty and are associated with extended sagittal tibial bone cuts. These can occur during the surgery, weaken the posterior cortex of the tibia and are associated with periprosthetic tibial plateau fractures. Although excellent long-term results have been reported with cemented unicompartmental knee arthroplasty, there is high interest in cementless fixation. The aim of the study was to compare fracture loads of cementless and cemented unicompartmental knee arthroplasty.MethodsTibial components of the Oxford Uni were implanted in six paired fresh-frozen tibiae with a defined extended saw cut (10°) at the dorsal cortex of each specimen. In one set, surgery was performed with cement fixation, and in the other, cementless components were implanted. Vertical loads were then applied under standardised conditions to fracture the specimens.ResultsMedian loads of 3.7 (0.7–6.9) kN led to fractures in the cemented group, whereas cementless fixated tibiae fractured with a median load of 1.6 (0.2–4.3) kN (P = 0.02).ConclusionThe loading capacity in tibiae with cementless components is significantly less compared to cemented fixation. The results show that in case of an extended sagittal bone cut patients especially those with poor bone quality who are treated with a cementless unicompartmental knee arthroplasty are at higher risk for periprosthetic tibial fractures.

[1]  S. Jaeger,et al.  Periprosthetic tibial fractures in unicompartmental knee arthroplasty as a function of extended sagittal saw cuts: an experimental study. , 2010, The Knee.

[2]  M. Jackson,et al.  Medial tibial plateau fracture complicating unicompartmental knee arthroplasty. , 2007, The Journal of arthroplasty.

[3]  R. Leighton,et al.  Unicondylar knee arthroplasty: a cementless perspective. , 2000, Canadian journal of surgery. Journal canadien de chirurgie.

[4]  J. Panisello,et al.  Long-term remodeling in proximal femur around a hydroxyapatite-coated anatomic stem: ten years densitometric follow-up. , 2009, The Journal of arthroplasty.

[5]  J. O'Connor,et al.  The Oxford meniscal unicompartmental knee. , 2002, The journal of knee surgery.

[6]  T. Tsuji,et al.  Distribution of bone mineral density in the proximal tibia in mid-teens , 2001, Journal of Bone and Mineral Metabolism.

[7]  J. Goodfellow,et al.  [Medial unicompartmental knee replacement using the "Oxford Uni" meniscal bearing knee]. , 2004, Der Orthopade.

[8]  M. Marcacci,et al.  Minimally invasive unicompartmental knee replacement: retrospective clinical and radiographic evaluation of 83 patients , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[9]  J. Kretzer,et al.  Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study. , 2011, Orthopedics.

[10]  A. Price,et al.  Oxford medial unicompartmental knee arthroplasty. A survival analysis of an independent series. , 2001, The Journal of bone and joint surgery. British volume.

[11]  Daniel L Riddle,et al.  Yearly incidence of unicompartmental knee arthroplasty in the United States. , 2008, The Journal of arthroplasty.

[12]  J. Galante,et al.  Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up. , 2005, The Journal of bone and joint surgery. American volume.

[13]  A. Price,et al.  Long-term Clinical Results of the Medial Oxford Unicompartmental Knee Arthroplasty , 2005, Clinical orthopaedics and related research.

[14]  S. Woo,et al.  Effects of postmortem storage by freezing on ligament tensile behavior. , 1986, Journal of biomechanics.

[15]  K Knutson,et al.  The routine of surgical management reduces failure after unicompartmental knee arthroplasty. , 2001, The Journal of bone and joint surgery. British volume.

[16]  S. Fuchs-Winkelmann,et al.  Primary stability of tibial components in TKA: in vitro comparison of two cementing techniques , 2009, Knee Surgery, Sports Traumatology, Arthroscopy.

[17]  Thomas Bruckner,et al.  Saw cuts in unicompartmental knee arthroplasty: an analysis of Sawbone preparations. , 2009, The Knee.

[18]  C. Engh,et al.  Femoral fracture during non-cemented total hip arthroplasty. , 1989, The Journal of bone and joint surgery. American volume.

[19]  J. Goodfellow,et al.  Medial tibial plateau fracture and the Oxford unicompartmental knee. , 2007, Orthopedics.

[20]  J. Goodfellow,et al.  Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year. , 2009, The Journal of bone and joint surgery. British volume.