Electrocardiogram Removal from Electromyogram of the Lumbar Muscles

Surface Electromyogram (SEMG) of the lumbar back muscles is being used for determining posture disorders for people suffering from low back pain. But SEMG of the back has a strong electrocardiogram (ECG) artefact. Research was conducted to determine the difference in the SEMG before and after the removal of ECG artefact from the SEMG recording using gating, subtraction and Multi-step Independent Component Analysis (MICA). The paper reports results of experiments conducted on eleven subjects over two days. The results show that removal of ECG artefact from the raw signal can substantially alter the RMS of the signal demonstrating the need for careful filtering of the signal for analysis. The paper also reports of the success of MICA for removing the ECG artefact.

[1]  A. Kaigle,et al.  Electromyographic Response of the Porcine Multifidus Musculature After Nerve Stimulation , 1995, Spine.

[2]  Terrence J. Sejnowski,et al.  Independent Component Analysis Using an Extended Infomax Algorithm for Mixed Subgaussian and Supergaussian Sources , 1999, Neural Computation.

[3]  P. Dolan,et al.  The use of surface EMG power spectral analysis in the evaluation of back muscle function. , 1997, Journal of rehabilitation research and development.

[4]  S Conforto,et al.  Optimal rejection of movement artefacts from myoelectric signals by means of a wavelet filtering procedure. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  D Chaffin,et al.  High-pass filtering to remove electrocardiographic interference from torso EMG recordings. , 1993, Clinical biomechanics.

[6]  David Walter Sitting or Standing? , 1982 .

[7]  A Bartolo,et al.  Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination. , 1996, Journal of applied physiology.

[8]  E. Oja,et al.  Independent Component Analysis , 2013 .

[9]  M. Pepper,et al.  Monitoring respiratory activity in neonates using diaphragmatic electromyograph , 1995, Medical and Biological Engineering and Computing.

[10]  W. Forrest,et al.  Muscle fibre direction of longissimus, iliocostalis and multifidus: landmark-derived reference lines. , 1989, Journal of anatomy.

[11]  M. Panjabi The stabilizing system of the spine. Part I. Function, dysfunction, adaptation, and enhancement. , 1992, Journal of spinal disorders.

[12]  N. Thakor,et al.  Removal of ECG interference from the EEG recordings in small animals using independent component analysis , 2001, Journal of Neuroscience Methods.

[13]  B. Knutsson Comparative value of electromyographic, myelographic and clinical-neurological examinations in diagnosis of lumbar root compression syndrome. , 1961, Acta orthopaedica Scandinavica. Supplementum.

[14]  J. Cram,et al.  The reliability of EMG muscle scanning. , 1994, International journal of psychosomatics : official publication of the International Psychosomatics Institute.

[15]  D.K. Kumar,et al.  Time-frequency analysis of SEMG with special consideration to the interelectrode spacing , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[16]  M. Panjabi The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. , 1992, Journal of spinal disorders.

[17]  F W Smith,et al.  Correlation between the MRI changes in the lumbar multifidus muscles and leg pain. , 2000, Clinical radiology.

[18]  R. Stein,et al.  The relation between the surface electromyogram and muscular force. , 1975, The Journal of physiology.