Repeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography.

PURPOSE The aim of this study was to investigate the repeatability of manual measurements of choroidal thickness in healthy subjects imaged on spectral domain optical coherence tomography (OCT) using the enhanced depth imaging (EDI) technique. METHODS Fifty consecutive, healthy, young, adult volunteers with no known eye disease were enrolled prospectively. Two good-quality horizontal and vertical line scans through the fovea were obtained for each eye. Using the manual calipers provided by the software of the proprietary device, two experienced OCT readers measured the subfoveal choroidal thickness (SFCT) of the horizontal and vertical line scans for all eyes. The readers were masked to each other's readings. Intraobserver, interobserver, and intrasession coefficients of repeatability (CRs) were calculated. RESULTS Mean (standard deviation [SD]) age of the study subjects was 38 (5) years (range, 30-49 years). Mean (SD) subfoveal choroidal thickness was 332 (90) μm (right eyes) and 332 (91) μm (left eyes). Intraobserver CR was approximately 23 (95% confidence interval [CI], 19-26) μm, whereas interobserver and intrasession CRs were greater at 32 (95% CI, 30-34) and 34 (95% CI, 32-36) μm, respectively. There was no significant difference in SFCT between all pairs of SFCT measurements except for the two intrasession vertical line scans. CONCLUSION A change of >32 μm was likely to exceed interobserver variability in SFCT. Future studies are required to estimate the repeatability of SFCT measurements in patients with chorioretinal pathology.

[1]  C. Costagliola,et al.  Enhanced depth imaging spectral-domain optical coherence tomography. , 2010, Retina.

[2]  J. Duker,et al.  COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESS , 2010, Retina.

[3]  J. Slakter,et al.  Enhanced depth imaging optical coherence tomography of the choroid in highly myopic eyes. , 2009, American journal of ophthalmology.

[4]  G. Wollstein,et al.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. , 2004, Investigative ophthalmology & visual science.

[5]  L. Pierro,et al.  Macular thickness interoperator and intraoperator reproducibility in healthy eyes using 7 optical coherence tomography instruments. , 2010, American journal of ophthalmology.

[6]  Boris Hermann,et al.  Wide-field optical coherence tomography of the choroid in vivo. , 2008, Investigative ophthalmology & visual science.

[7]  Farzin Forooghian,et al.  Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema. , 2008, Investigative ophthalmology & visual science.

[8]  A Erginay,et al.  Reproducibility of retinal mapping using optical coherence tomography. , 2001, Archives of ophthalmology.

[9]  J. Kiel,et al.  Ocular perfusion pressure and choroidal blood flow in the rabbit. , 1995, Investigative ophthalmology & visual science.

[10]  Veit Sturm,et al.  Reproducibility of retinal thickness measurements in patients with age‐related macular degeneration using 3D Fourier‐domain optical coherence tomography (OCT) (Topcon 3D‐OCT 1000) , 2011, Acta ophthalmologica.

[11]  Lala Ceklic,et al.  Macular thickness measurements in healthy eyes using six different optical coherence tomography instruments. , 2009, Investigative ophthalmology & visual science.

[12]  Vikram S Brar,et al.  Comparison of retinal thickness in normal eyes using Stratus and Spectralis optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[13]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[14]  R. Spaide,et al.  ENHANCED DEPTH IMAGING OPTICAL COHERENCE TOMOGRAPHY OF THE CHOROID IN CENTRAL SEROUS CHORIORETINOPATHY , 2009, Retina.

[15]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[16]  Francesco Bandello,et al.  Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography. , 2005, Archives of ophthalmology.

[17]  P T de Jong,et al.  Morphometric analysis of Bruch's membrane, the choriocapillaris, and the choroid in aging. , 1994, Investigative ophthalmology & visual science.

[18]  R. Spaide,et al.  A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes. , 2009, American journal of ophthalmology.

[19]  Toyohiko Yatagai,et al.  Visualization of sub-retinal pigment epithelium morphologies of exudative macular diseases by high-penetration optical coherence tomography. , 2009, Investigative ophthalmology & visual science.

[20]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[21]  Iwona Gorczynska,et al.  Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head. , 2008, Investigative ophthalmology & visual science.

[22]  L. da Cruz,et al.  Repeatability of stratus optical coherence tomography measures in neovascular age-related macular degeneration. , 2008, Investigative ophthalmology & visual science.

[23]  G. Ying,et al.  In vivo human choroidal thickness measurements: evidence for diurnal fluctuations. , 2009, Investigative ophthalmology & visual science.

[24]  Richard F Spaide,et al.  Enhanced depth imaging optical coherence tomography of retinal pigment epithelial detachment in age-related macular degeneration. , 2009, American journal of ophthalmology.

[25]  D. Lu,et al.  Adrenergic supersensitivity of rabbit choroidal blood vessels after sympathetic denervation , 2001, Current eye research.

[26]  D. Altman,et al.  Measurement error. , 1996, BMJ.