Development of fast patient position verification software using 2D-3D image registration and its clinical experience

To improve treatment workflow, we developed a graphic processing unit (GPU)-based patient positional verification software application and integrated it into carbon-ion scanning beam treatment. Here, we evaluated the basic performance of the software. The algorithm provides 2D/3D registration matching using CT and orthogonal X-ray flat panel detector (FPD) images. The participants were 53 patients with tumors of the head and neck, prostate or lung receiving carbon-ion beam treatment. 2D/3D-ITchi-Gime (ITG) calculation accuracy was evaluated in terms of computation time and registration accuracy. Registration calculation was determined using the similarity measurement metrics gradient difference (GD), normalized mutual information (NMI), zero-mean normalized cross-correlation (ZNCC), and their combination. Registration accuracy was dependent on the particular metric used. Representative examples were determined to have target registration error (TRE) = 0.45 ± 0.23 mm and angular error (AE) = 0.35 ± 0.18° with ZNCC + GD for a head and neck tumor; TRE = 0.12 ± 0.07 mm and AE = 0.16 ± 0.07° with ZNCC for a pelvic tumor; and TRE = 1.19 ± 0.78 mm and AE = 0.83 ± 0.61° with ZNCC for lung tumor. Calculation time was less than 7.26 s.The new registration software has been successfully installed and implemented in our treatment process. We expect that it will improve both treatment workflow and treatment accuracy.

[1]  Fang-Fang Yin,et al.  6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  George T. Y. Chen,et al.  A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. , 2005, Medical physics.

[3]  George T. Y. Chen,et al.  A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup. , 2005, Medical physics.

[4]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[5]  Nobuyuki Kanematsu,et al.  Recent innovations in carbon-ion radiotherapy. , 2010, Journal of radiation research.

[6]  Philippe Lambin,et al.  How costly is particle therapy? Cost analysis of external beam radiotherapy with carbon-ions, protons and photons. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[8]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[9]  W. Bragg,et al.  LXXIV. On the ionization curves of radium , 1904 .

[10]  George T. Y. Chen,et al.  Proton radiography and fluoroscopy of lung tumors: a Monte Carlo study using patient-specific 4DCT phantoms. , 2011, Medical physics.

[11]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[12]  D. Moffett,et al.  Proton imaging for medical applications. , 1980, Radiology.

[13]  W. Press,et al.  Numerical Recipes in C++: The Art of Scientific Computing (2nd edn)1 Numerical Recipes Example Book (C++) (2nd edn)2 Numerical Recipes Multi-Language Code CD ROM with LINUX or UNIX Single-Screen License Revised Version3 , 2003 .

[14]  Takuji Furukawa,et al.  Amplitude-based gated phase-controlled rescanning in carbon-ion scanning beam treatment planning under irregular breathing conditions using lung and liver 4DCTs , 2014, Journal of radiation research.

[15]  George Starkschall,et al.  Assessment of gross tumor volume regression and motion changes during radiotherapy for non-small-cell lung cancer as measured by four-dimensional computed tomography. , 2007, International journal of radiation oncology, biology, physics.

[16]  Takuji Furukawa,et al.  Patient handling system for carbon ion beam scanning therapy , 2012, Journal of applied clinical medical physics.

[17]  Joachim Denzler,et al.  Progressive Attenuation Fields : Fast 2 D-3 D Image Registration Without Precomputation , 2004 .

[18]  Balraj Naren,et al.  Medical Image Registration , 2022 .

[19]  Shinichi Minohara,et al.  Development of a GPU-based multithreaded software application to calculate digitally reconstructed radiographs for radiotherapy , 2009, Radiological physics and technology.

[20]  Katsuyuki Tanimoto,et al.  First clinical experience in carbon ion scanning beam therapy: retrospective analysis of patient positional accuracy , 2012, Journal of radiation research.

[21]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[22]  J. Wong,et al.  Interfractional prostate shifts: review of 1870 computed tomography (CT) scans obtained during image-guided radiotherapy using CT-on-rails for the treatment of prostate cancer. , 2008, International journal of radiation oncology, biology, physics.