Signal Processing Overview of Optical Coherence Tomography Systems for Medical Imaging

Optical Coherence Tomography (OCT) is a new medical imaging modality with resolution in the μm range and depth of imaging in the mm range. OCT is based on the principle of low coherence interferometry. This modality has been applied to imaging in various biological applications including ophthalmology, gastroenterology, dentistry, cardiology, tumor margining, etc. OCT systems are signal processing intensive and well suited for embedded implementations using digital signal processors (DSP) and system-on-chip (SoC) application processors. Low-power DSP and SoC are key to making low cost, low power and portable OCT systems. The different types of OCT systems are described in this white paper with focus being on signal processing algorithms used in such systems.

[1]  Jadwiga Rogowska,et al.  Image processing techniques for noise removal, enhancement and segmentation of cartilage OCT images. , 2002, Physics in medicine and biology.

[2]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[3]  Zhihua Ding,et al.  High-resolution optical coherence tomography over a large depth range with an axicon lens. , 2002, Optics letters.

[4]  Claudio Vinegoni,et al.  Spectroscopic spectral-domain optical coherence microscopy. , 2006, Optics letters.

[5]  Daniel L Marks,et al.  Autofocus algorithm for dispersion correction in optical coherence tomography. , 2003, Applied optics.

[6]  Siavash Yazdanfar,et al.  Real-time in vivo color Doppler optical coherence tomography. , 2002, Journal of biomedical optics.

[7]  Chenyang Xu,et al.  Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm. , 2004, Optics express.

[8]  J. Fujimoto,et al.  Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second. , 2007, Optics letters.

[9]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[10]  J. Fujimoto,et al.  Spectroscopic optical coherence tomography. , 2000 .

[11]  N Iftimia,et al.  OCT-based arterial elastography: robust estimation exploiting tissue biomechanics. , 2004, Optics express.

[12]  J. Duker,et al.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation. , 2004, Optics express.

[13]  A. Fercher,et al.  Optical coherence tomography - principles and applications , 2003 .

[14]  M. Larsen,et al.  Enhanced optical coherence tomography imaging by multiple scan averaging , 2005, British Journal of Ophthalmology.

[15]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE 1985 Ultrasonics Symposium.

[16]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[17]  C. Hitzenberger,et al.  High speed spectral domain polarization sensitive optical coherence tomography of the human retina. , 2005, Optics express.

[18]  Christian Ahlers,et al.  Three-dimensional polarization sensitive OCT imaging and interactive display of the human retina. , 2009, Optics express.

[19]  Julius Pekar,et al.  High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance. , 2003, Optics express.

[20]  Ruikang K. Wang,et al.  Theory, developments and applications of optical coherence tomography , 2005 .

[21]  T. Yatagai,et al.  Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method. , 2006, Optics express.

[22]  Daniel L Marks,et al.  Real-time interferometric synthetic aperture microscopy. , 2008, Optics express.

[23]  Lingfeng Yu,et al.  Improved lateral resolution in optical coherence tomography by digital focusing using two-dimensional numerical diffraction method. , 2007, Optics express.

[24]  Toyohiko Yatagai,et al.  Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples , 2004 .

[25]  C K Hitzenberger,et al.  Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography. , 2000, Optics letters.

[26]  James Fujimoto,et al.  Optical coherence tomography contrast enhancement using spectroscopic analysis with spectral autocorrelation. , 2004, Optics express.

[27]  Iwona Gorczynska,et al.  Ultrahigh-speed optical coherence tomography for three-dimensional and en face imaging of the retina and optic nerve head. , 2008, Investigative ophthalmology & visual science.

[28]  Matthew Brenner,et al.  Real-time swept source optical coherence tomography imaging of the human airway using a microelectromechanical system endoscope and digital signal processor. , 2008, Journal of biomedical optics.

[29]  Brett E. Bouma,et al.  Tissue Elasticity Estimation with Optical Coherence Elastography: Toward Mechanical Characterization of In Vivo Soft Tissue , 2005, Annals of Biomedical Engineering.