Influence of press-fit parameters on the primary stability of uncemented femoral resurfacing implants.

Primary stability is essential to the success of uncemented prostheses. It is strongly influenced by implantation technique, implant design and bone quality. The goal of this study was to investigate the effect of press-fit parameters on the primary stability of uncemented femoral head resurfacing prostheses. An in vitro study with human specimens and prototype implants (nominal radial interference 170 and 420 microm) was used to investigate the effect of interference on primary stability. A finite element model was used to assess the influence of interference, friction between implant and bone, and bone quality. Primary stability was represented by the torque capacity of the implant. The model predicted increasing stability with actual interference, bone quality and friction coefficient; plastic deformation of the bone began at interferences of less than 100 microm. Experimentally, however, stability was not related to interference. This may be due to abrasion or the collapse of trabecular bone structures at higher interferences, which could not be captured by the model. High nominal interferences as tested experimentally appear unlikely to result in improved stability clinically. An implantation force of about 2,500 N was estimated to be sufficient to achieve a torque capacity of about 30 N m with a small interference (70 microm).

[1]  H. Amstutz,et al.  Fracture of the neck of the femur after surface arthroplasty of the hip. , 2004, The Journal of bone and joint surgery. American volume.

[2]  Harlan C. Amstutz,et al.  Metal on Metal Surface Replacement of the Hip: Technique, Fixation, and Early Results , 1996, Clinical orthopaedics and related research.

[3]  M. Ritter,et al.  Failure Mechanisms of Total Hip Resurfacing: Implications for the Present , 2006, Clinical orthopaedics and related research.

[4]  M Honl,et al.  Artificial composite bone as a model of human trabecular bone: the implant-bone interface. , 2007, Journal of biomechanics.

[5]  J. M. Lee,et al.  Observations on the Effect of Movement on Bone Ingrowth into Porous‐Surfaced Implants , 1986, Clinical orthopaedics and related research.

[6]  T. Keaveny,et al.  Dependence of yield strain of human trabecular bone on anatomic site. , 2001, Journal of biomechanics.

[7]  M M Morlock,et al.  Friction moments of large metal-on-metal hip joint bearings and other modern designs. , 2008, Medical engineering & physics.

[8]  S. Vowler,et al.  Hydroxyapatite-coated femoral implant in metal-on-metal resurfacing hip arthroplasty: minimum of two years follow-up. , 2005, The Orthopedic clinics of North America.

[9]  G. Niebur,et al.  Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. , 2004, Journal of biomechanics.

[10]  N Shiba,et al.  Biomechanical study of the resurfacing hip arthroplasty: finite element analysis of the femoral component. , 2000, The Journal of arthroplasty.

[11]  W. Harris,et al.  In Vivo Skeletal Responses to Porous-Surfaced Implants Subjected to Small Induced Motions* , 1997, The Journal of bone and joint surgery. American volume.

[12]  D. Davy,et al.  The effect of damage on the viscoelastic behavior of human vertebral trabecular bone. , 2006, Journal of biomechanical engineering.

[13]  R Huiskes,et al.  Interface stresses in the resurfaced hip. Finite element analysis of load transmission in the femoral head. , 1985, Acta orthopaedica Scandinavica.

[14]  K. Radermacher,et al.  Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. , 2000, Journal of biomechanics.

[15]  W Rüther,et al.  Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  T. Smith,et al.  Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: an in-vitro model. , 2006, Journal of biomechanical engineering.