Innovations in energy expenditure assessment

Purpose of review Optimal nutritional therapy has been associated with better clinical outcomes and requires providing energy as closed as possible to measured energy expenditure. We reviewed the current innovations in energy expenditure assessment in humans, focusing on indirect calorimetry and other new alternative methods. Recent findings Although considered the reference method to measure energy expenditure, the use of indirect calorimetry is currently limited by the lack of an adequate device. However, recent technical developments may allow a broader use of indirect calorimetry for in-patients and out-patients. An ongoing international academic initiative to develop a new indirect calorimeter aimed to provide innovative and affordable technical solutions for many of the current limitations of indirect calorimetry. New alternative methods to indirect calorimetry, including CO2 measurements in mechanically ventilated patients, isotopic approaches and accelerometry-based fitness equipments, show promises but have been either poorly studied and/or are not accurate compared to indirect calorimetry. Therefore, to date, energy expenditure measured by indirect calorimetry remains the gold standard to guide nutritional therapy. Summary Some new innovative methods are demonstrating promises in energy expenditure assessment, but still need to be validated. There is an ongoing need for easy-to-use, accurate and affordable indirect calorimeter for daily use in in-patients and out-patients.

[1]  Wolfgang Taube,et al.  Validity of sports watches when estimating energy expenditure during running , 2017, BMC Sports Science, Medicine and Rehabilitation.

[2]  L. Sardinha,et al.  Usefulness of motion sensors to estimate energy expenditure in children and adults: a narrative review of studies using DLW , 2017, European Journal of Clinical Nutrition.

[3]  P. Honore,et al.  VCO2 calorimetry: stop tossing stones, it’s time for building! , 2016, Critical Care.

[4]  A. Madden,et al.  Estimation of energy expenditure using prediction equations in overweight and obese adults: a systematic review. , 2016, Journal of human nutrition and dietetics : the official journal of the British Dietetic Association.

[5]  J. van Rosmalen,et al.  Validation of ventilator-derived VCO2 measurements to determine energy expenditure in ventilated critically ill children. , 2017, Clinical nutrition.

[6]  Jillian Trabulsi,et al.  Evidence analysis library review of best practices for performing indirect calorimetry in healthy and non-critically ill individuals. , 2015, Journal of the Academy of Nutrition and Dietetics.

[7]  Peter Cudd,et al.  Feasibility study of portable technology for weight loss and HbA1c control in type 2 diabetes , 2016, BMC Medical Informatics and Decision Making.

[8]  C. Voigt,et al.  Carbon stable‐isotope tracking in breath for comparative studies of fuel use , 2016, Annals of the New York Academy of Sciences.

[9]  P. Singer,et al.  Resting energy expenditure, calorie and protein consumption in critically ill patients: a retrospective cohort study , 2016, Critical Care.

[10]  G. Bedogni,et al.  External validation of equations to estimate resting energy expenditure in 14952 adults with overweight and obesity and 1948 adults with normal weight from Italy. , 2017, Clinical nutrition.

[11]  C. Pichard,et al.  Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group. , 2017, Clinical nutrition.

[12]  A. Santos-Lozano,et al.  Is the SenseWear Armband accurate enough to quantify and estimate energy expenditure in healthy adults? , 2017, Annals of translational medicine.

[13]  Michael Sjöström,et al.  Body movement and physical activity energy expenditure in children and adolescents: how to adjust for differences in body size and age. , 2004, The American journal of clinical nutrition.

[14]  D. Macfarlane Open-circuit respirometry: a historical review of portable gas analysis systems , 2017, European Journal of Applied Physiology.

[15]  S. Andreassen,et al.  Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO2-based indirect calorimetry , 2016, Annals of Intensive Care.

[16]  M. Malbrain,et al.  Does the use of indirect calorimetry change outcome in the ICU? Yes it does , 2018, Current opinion in clinical nutrition and metabolic care.

[17]  Gregory J Welk,et al.  Comparison of Consumer and Research Monitors under Semistructured Settings. , 2016, Medicine and science in sports and exercise.

[18]  D. Eggett,et al.  Comparing Steady State to Time Interval and Non–Steady State Measurements of Resting Metabolic Rate , 2017, Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition.

[19]  Patrick Wahl,et al.  Criterion-Validity of Commercially Available Physical Activity Tracker to Estimate Step Count, Covered Distance and Energy Expenditure during Sports Conditions , 2017, Front. Physiol..

[20]  Torsten Lehmann,et al.  Instantaneous VO2 from a wearable device. , 2018, Medical engineering & physics.

[21]  C. Pichard,et al.  Energy expenditure in mechanically ventilated patients: The weight of body weight! , 2017, Clinical nutrition.

[22]  A. Girbes,et al.  Ventilator-derived carbon dioxide production to assess energy expenditure in critically ill patients: proof of concept , 2015, Critical Care.

[23]  Najate Achamrah,et al.  Validity of Predictive Equations for Resting Energy Expenditure Developed for Obese Patients: Impact of Body Composition Method , 2018, Nutrients.

[24]  C. Pichard,et al.  Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry? , 2017, Critical Care.

[25]  P. Elbers,et al.  VCO2-derived energy expenditure: do not throw the baby out with the bath water! , 2017, Critical Care.

[26]  C. Pichard,et al.  Methods to validate the accuracy of an indirect calorimeter in the in-vitro setting. , 2017, Clinical nutrition ESPEN.

[27]  J. Wernerman,et al.  Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients , 2016, Critical Care.

[28]  C. Lafortuna,et al.  Development and validation of new predictive equation for resting energy expenditure in adults with overweight and obesity. , 2017, Clinical nutrition.

[29]  J. Ruiz,et al.  Reliability of resting metabolic rate measurements in young adults: Impact of methods for data analysis. , 2017, Clinical nutrition.

[30]  E. Melanson,et al.  Inter- and intraindividual correlations of background abundances of 2H, 18O and 17O in human urine and implications for DLW measurements , 2015, European Journal of Clinical Nutrition.

[31]  Gil Guerra-Júnior,et al.  Minimum Time to Achieve the Steady State and Optimum Abbreviated Period to Estimate the Resting Energy Expenditure by Indirect Calorimetry in Healthy Young Adults. , 2016, Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition.