Hyaluronic acid containing hydrogels for the reduction of protein adsorption.

Recently, new contact lens materials have been introduced which are reported to improve comfort by incorporating wetting agents either in a releasable or nonreleasable form. In the present work, model lens materials based on poly(2-hydroxyethyl methacrylate) (pHEMA) were developed which incorporate releasable or crosslinked and therefore physically entrapped hyaluronic acid (HA) of various molecular weights as a wetting agent. Crosslinked HA, despite being only present in very small amounts, resulted in consistently lower water contact angles over 4h in comparison to controls, indicating that HA is present at the interface and was not being released over time. The presence of HA in the material was further confirmed by increases in the glass transition temperature measured by differential scanning calorimetry (DSC), and small increases in the stiffness as measured by Instron testing. This crosslinking procedure appeared to have no effect on optical transparency using 35 kDa HA, whereas small decreases in optical transparency at higher wavelengths were noted for the 169 kDa HA crosslinked material, as measured by UV spectrophotometry. Most importantly, protein adsorption results indicated that the adsorption of all proteins studied was considerably decreased by the presence of the small amount of crosslinked HA. The results provide insight into the mechanisms of comfort improvement with commercially available lens materials and suggest that HA containing materials may have significant potential for use in contact lens applications.

[1]  S. Kinoshita,et al.  Effectiveness of hyaluronan on corneal epithelial barrier function in dry eye , 1997, The British journal of ophthalmology.

[2]  M. Göbbels,et al.  Corneal epithelial permeability of dry eyes before and after treatment with artificial tears. , 1992, Ophthalmology.

[3]  A. Simmons,et al.  Lysozyme interaction with poly(HEMA)-based hydrogel. , 2006, Biomaterials.

[4]  J. Wolffsohn,et al.  Clinical performance of daily disposable soft contact lenses using sustained release technology. , 2006, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[5]  M. Tetz,et al.  Effect of healon5 and 4 other viscoelastic substances on intraocular pressure and endothelium after cataract surgery , 2001, Journal of cataract and refractive surgery.

[6]  Si-Nae Park,et al.  Biological characterization of EDC-crosslinked collagen-hyaluronic acid matrix in dermal tissue restoration. , 2003, Biomaterials.

[7]  B. Tighe,et al.  An in Vivo Comparison of the Kinetics of Protein and Lipid Deposition on Group II and Group IV Frequent-Replacement Contact Lenses , 2000, Optometry and vision science : official publication of the American Academy of Optometry.

[8]  N. Pritchard,et al.  A multi‐centre study of lapsed contact lens wearers , 2002, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[9]  G. Milazzo,et al.  Long term treatment with sodium hyaluronate-containing artificial tears reduces ocular surface damage in patients with dry eye , 2002, The British journal of ophthalmology.

[10]  J. Vogt,et al.  Soft contact lens polymers: an evolution. , 2001, Biomaterials.

[11]  N. Brennan,et al.  Deposits and symptomatology with soft contact lens wear , 2000 .

[12]  S. Suri,et al.  In vitro evaluation of in situ gels as short term vitreous substitutes. , 2006, Journal of biomedical materials research. Part A.

[13]  R. Berg,et al.  Biomedical applications of hyaluronic acid , 2006 .

[14]  H. Sheardown,et al.  Crosslinking of collagen with dendrimers. , 2005, Journal of biomedical materials research. Part A.

[15]  H. Sheardown,et al.  Dendrimer crosslinked collagen as a corneal tissue engineering scaffold: mechanical properties and corneal epithelial cell interactions. , 2006, Biomaterials.

[16]  M. Nakamura,et al.  Hyaluronan stimulates corneal epithelial migration. , 1991, Experimental eye research.

[17]  J. Lally,et al.  The elution of poly (vinyl alcohol) from a contact lens: the realization of a time release moisturizing agent/artificial tear. , 2007, Journal of biomedical materials research. Part B, Applied biomaterials.

[18]  G. Young,et al.  Multi-centre evaluation of two daily disposable contact lenses. , 2007, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[19]  W. J. Wang,et al.  Crosslinked collagen/chitosan matrix for artificial livers. , 2003, Biomaterials.

[20]  A. Bright,et al.  The composition and interfacial properties of tears, tear substitutes and tear models , 1993 .

[21]  P. J. Murphy,et al.  Effectiveness of sodium hyaluronate eyedrops in the treatment of dry eye , 2005, Graefe's Archive for Clinical and Experimental Ophthalmology.

[22]  R. Mandell,et al.  Initial in Vivo Tear Protein Deposition on Individual Hydrogel Contact Lenses , 1990, Optometry and vision science : official publication of the American Academy of Optometry.

[23]  I. Benzie,et al.  Investigation of Corneal Effect of Different Types of Artificial Tears in a Simulated Dry Eye Condition Using a Novel Porcine Dry Eye Model (pDEM) , 2006, Cornea.

[24]  M. Brook,et al.  Surface properties of PEO–silicone composites: reducing protein adsorption , 2005, Journal of biomaterials science. Polymer edition.

[25]  J. A. Hubbell,et al.  Surface Treatments of Polymers for Biocompatibility , 1996 .

[26]  M. Morra,et al.  Evaluation of interfacial properties of hyaluronan coated poly(methylmethacrylate) intraocular lenses , 2000, Journal of biomaterials science. Polymer edition.

[27]  G. Kissling,et al.  Topical application of hyaluronic acid and chondroitin sulfate in the treatment of dry eyes. , 1987, American journal of ophthalmology.

[28]  B. Ratner,et al.  Adsorption of proteins from artificial tear solutions to contact lens materials. , 1988, Investigative Ophthalmology and Visual Science.