Formation of three-dimensional Parylene C structures via thermoforming

The thermoplastic nature of Parylene C is leveraged to enable the formation of three-dimensional structures using a thermal forming (thermoforming) technique. Thermoforming involves the heating of Parylene films above its glass transition temperature while they are physically confined in the final desired conformation. Micro and macro scale three-dimensional structures composed of Parylene thin films were developed using the thermoforming process, and the resulting chemical and mechanical changes to the films were characterized. No large changes to the surface and bulk chemistries of the polymer were observed following the thermoforming process conducted in vacuum. Heat treated structures exhibited increased stiffness by a maximum of 37% depending on the treatment temperature, due to an increase in crystallinity of the Parylene polymer. This study revealed important property changes resulting from the process, namely (1) the development of high strains in thermoformed areas of small radii of curvature (30?90??m) and (2) ?1.5% bulk material shrinkage in thermoformed multilayered Parylene?Parylene and Parylene?metal?Parylene films. Thermoforming is a simple process whereby three-dimensional structures can be achieved from Parylene C-based thin film structures with tunable mechanical properties as a function of treatment temperature.

[1]  G. Loeb,et al.  Parylene as a Chronically Stable, Reproducible Microelectrode Insulator , 1977, IEEE Transactions on Biomedical Engineering.

[2]  K. J. Ives,et al.  Experimental Methods (2) , 1978 .

[3]  D. Smith,et al.  Thermal oxidative stability of poly‐p‐xylylenes , 1980 .

[4]  H. Dreuth,et al.  Thermoplastic structuring of thin polymer films , 1999 .

[5]  Y. Tai,et al.  Photoresist as a sacrificial layer by dissolution in acetone , 2001, Technical Digest. MEMS 2001. 14th IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.01CH37090).

[6]  Th. Schaller,et al.  Low-cost thermoforming of micro fluidic analysis chips , 2002 .

[7]  Guo-Hua Feng,et al.  Universal concept for fabricating micron to millimeter sized 3-D parylene structures on rigid and flexible substrates , 2003, The Sixteenth Annual International Conference on Micro Electro Mechanical Systems, 2003. MEMS-03 Kyoto. IEEE.

[8]  K. Moon,et al.  Wafer bonding using microwave heating of parylene intermediate layers , 2004 .

[9]  Hong-Seok Noha,et al.  Parylene micromolding, a rapid and low-cost fabrication method for parylene microchannel , 2004 .

[10]  T. Lu,et al.  Correlation Between Bond Cleavage in Parylene N and the Degradation of Its Dielectric Properties , 2004 .

[11]  K. Najafi,et al.  Characterization of low-temperature wafer bonding using thin-film parylene , 2005, Journal of Microelectromechanical Systems.

[12]  J.D. Weiland,et al.  Integrated Flexible Ocular Coil for Power and Data Transfer in Retinal Prostheses , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[13]  T. Pajkossy,et al.  Impedance spectroscopy at interfaces of metals and aqueous solutions — Surface roughness, CPE and related issues , 2005 .

[14]  S. Takeuchi,et al.  Fabrication of Flexible Neural Probes With Built-In Microfluidic Channels by Thermal Bonding of Parylene , 2006, Journal of Microelectromechanical Systems.

[15]  Koji Ikuta,et al.  The membrane micro emboss (MeME) process for fabricating 3-D microfluidic device formed from thin polymer membrane , 2006 .

[16]  R. Andersen,et al.  Electrolysis-based Parylene Balloon Actuators for Movable Neural Probes , 2007, IEEE International Conference on Nano/Micro Engineered and Molecular Systems.

[17]  R. Maeda,et al.  Fabrication of a micro patterned parylene-C master by hot-embossing and its application to metallic mold replication , 2007 .

[18]  Igor A. Lavrov,et al.  Flexible parylene-based multielectrode array technology for high-density neural stimulation and recording , 2008 .

[19]  Po-Ying Li,et al.  Plasma removal of Parylene C , 2008 .

[20]  K. Ikuta,et al.  “Membrane micro emboss following excimer laser ablation (MeME-X) process” for pressure-driven micro active catheter , 2008, 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems.

[21]  Florian Solzbacher,et al.  Effect of thermal and deposition processes on surface morphology, crystallinity, and adhesion of Parylene-C , 2008 .

[22]  Y. Tai,et al.  Parylene-membrane piezoresistive pressure sensors with XeF2-etched cavity , 2008, 2008 IEEE Sensors.

[23]  Po-Ying Li,et al.  Integrated flow sensing for focal biochemical stimulation , 2008, 2008 3rd IEEE International Conference on Nano/Micro Engineered and Molecular Systems.

[24]  Florian Solzbacher,et al.  Encapsulation of an Integrated Neural Interface Device With Parylene C , 2009, IEEE Transactions on Biomedical Engineering.

[25]  M. Maillard,et al.  Structural and dielectric study of parylene C thin films , 2009 .

[26]  Y. Tai,et al.  Parylene to silicon adhesion enhancement , 2009, TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference.

[27]  Ulrich Schmid,et al.  The impact of annealing temperature and time on the electrical performance of Ti/Pt thin films , 2010 .

[28]  Florian Solzbacher,et al.  A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex. , 2010, Biomaterials.

[29]  T. Stieglitz,et al.  Characterization of parylene C as an encapsulation material for implanted neural prostheses. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[30]  Wei Wang,et al.  Fabrication and Characterization of a Parylene-Based Three-Dimensional Microelectrode Array for Use in Retinal Prosthesis , 2010, Journal of Microelectromechanical Systems.

[31]  J. Uhlemann,et al.  Influence of artificial body fluids and medical sterilization procedures on chemical stability of Parylene C , 2010, 2010 Proceedings 60th Electronic Components and Technology Conference (ECTC).

[32]  Yu-Chong Tai,et al.  Flexible parylene-based 3-D coiled cable , 2010, 2010 IEEE 5th International Conference on Nano/Micro Engineered and Molecular Systems.

[33]  Y. Tai,et al.  Parylene-based integrated wireless single-channel neurostimulator , 2011 .

[34]  A. Vasenkov Atomistic modeling of parylene-metal interactions for surface micro-structuring , 2011, Journal of molecular modeling.

[35]  Brian J. Kim,et al.  Epoxy-less packaging methods for electrical contact to parylene-based flat flexible cables , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[36]  R. A. Meirom,et al.  Fatigue-induced grain coarsening in nanocrystalline platinum films , 2011 .

[37]  L. Rieth,et al.  Evaluation of the packaging and encapsulation reliability in fully integrated, fully wireless 100 channel Utah Slant Electrode Array (USEA): Implications for long term functionality , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[38]  W. Leitenberger,et al.  Strain relaxation and vacancy creation in thin platinum films. , 2011, Physical review letters.

[39]  K. Winey,et al.  The influence of thermal history on structure and water transport in Parylene C coatings , 2011 .

[40]  Alan F. Murray,et al.  Controlled Adhesion and Growth of Long Term Glial and Neuronal Cultures on Parylene-C , 2011, PloS one.

[41]  Matthias Wessling,et al.  Thermoforming of Film‐Based Biomedical Microdevices , 2011, Advanced materials.

[42]  E. Meng,et al.  Impedance-Based Force Transduction Within Fluid-Filled Parylene Microstructures , 2011, Journal of Microelectromechanical Systems.

[43]  J. Lin MEMS for Glaucoma , 2012 .

[44]  W. Fang,et al.  A pneumatic neural probe structure fabricated by parylene thermal bonding technique , 2012, 2012 IEEE 25th International Conference on Micro Electro Mechanical Systems (MEMS).

[45]  Akhlesh Lakhtakia,et al.  Toward bioinspired parylene-C coatings of implant surfaces , 2012, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[46]  Brian J. Kim,et al.  3D Parylene sheath neural probe for chronic recordings , 2013, Journal of neural engineering.

[47]  Evaluation of post-fabrication thermoforming process for intracortical Parylene sheath electrode , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[48]  Three dimensional transformation of Parylene thin film structures via thermoforming , 2013, 2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS).

[49]  Brian J. Kim,et al.  Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration. , 2013, Lab on a chip.

[50]  Amos Maritan,et al.  Flory theory for polymers , 2013, Journal of physics. Condensed matter : an Institute of Physics journal.

[51]  Thomas Stieglitz,et al.  The effects of annealing on mechanical, chemical, and physical properties and structural stability of Parylene C , 2013, Biomedical microdevices.

[52]  Ellis Meng,et al.  An Electrochemical Investigation of the Impact of Microfabrication Techniques on Polymer-Based Microelectrode Neural Interfaces , 2015, Journal of Microelectromechanical Systems.