Immunoassay for folic acid detection in vitamin-fortified milk based on electrochemical magneto sensors.
暂无分享,去创建一个
M. Marco | S. Hernández | M. Pividori | S. Alegret | A. Lermo | R. Galve | S. Fabiano
[1] M. Guo,et al. Quantification of water-soluble vitamins in milk-based infant formulae using biosensor-based assays , 2008 .
[2] M. Delwiche,et al. Towards Q-PCR of pathogenic bacteria with improved electrochemical double-tagged genosensing detection. , 2008, Biosensors & bioelectronics.
[3] M. Marco,et al. Electrochemical magneto immunosensing of antibiotic residues in milk. , 2007, Biosensors & bioelectronics.
[4] S. Hernández,et al. In situ DNA amplification with magnetic primers for the electrochemical detection of food pathogens. , 2007, Biosensors & bioelectronics.
[5] Frédéric Reymond,et al. Disposable microfluidic ELISA for the rapid determination of folic acid content in food products , 2006, Analytical and bioanalytical chemistry.
[6] J. S. Gándara,et al. Screening for folic acid content in vitamin-fortified beverages , 2006 .
[7] Alessandra Bonanni,et al. Genomagnetic assay based on label-free electrochemical detection using magneto-composite electrodes , 2006 .
[8] M. Marco,et al. Electrochemical magnetoimmunosensing strategy for the detection of pesticides residues. , 2006, Analytical chemistry.
[9] J. Gregory,et al. The analysis of folate and its metabolic precursors in biological samples. , 2006, Analytical biochemistry.
[10] M. Isabel Pividori,et al. Electrochemical Genosensing Based on Rigid Carbon Composites. A Review , 2005 .
[11] M. Mascini,et al. A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads and carbon-based screen-printed electrodes (SPCEs) for the detection of polychlorinated biphenyls (PCBs) , 2005 .
[12] D. Weir,et al. Measurements of sub-nanomolar concentrations of unmetabolised folic acid in serum. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[13] Rene Kizek,et al. Electrochemical enzyme-linked immunoassay in a DNA hybridization sensor , 2002 .
[14] T. J. Mathews,et al. Impact of folic acid fortification of the US food supply on the occurrence of neural tube defects. , 2001, JAMA.
[15] Johan Lindeberg,et al. Biosensor-based determination of folic acid in fortified food , 2000 .
[16] P. Finglas,et al. Determination of biotin and folate in infant formula and milk by optical biosensor-based immunoassay. , 2000, Journal of AOAC International.
[17] G. Oakley,et al. Folic acid fortification , 1999, The Lancet.
[18] M. Goggins,et al. Unmetabolized folic acid in serum: acute studies in subjects consuming fortified food and supplements. , 1997, The American journal of clinical nutrition.
[19] T. Dhar,et al. Antibody to folic acid: increased specificity and sensitivity in ELISA by using epsilon-aminocaproic acid modified BSA as the carrier protein. , 1995, Journal of immunological methods.
[20] B. Hammock,et al. Influence of the ELISA format and the hapten-enzyme conjugate on the sensitivity of an immunoassay for s-triazine herbicides using monoclonal antibodies , 1992 .
[21] M. M. Bradford. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. , 1976, Analytical biochemistry.
[22] S. Alegret. Chapter 1 Integration, a new paradigm in analytical chemistry , 2003 .
[23] Paul Finglas,et al. Encyclopedia of food sciences and nutrition , 2003 .
[24] K. Rubach,et al. Bestimmung von Biotin und Folsäure in vitaminisierten lebensmitteln mittels kompetitivem Bindungsprotein Assay (CBPA) und ELISA (Enzyme-Linked Immunosorbent Assay) , 1991 .