Initial results from the Sherbrooke avalanche photodiode positron tomograph

The design features and engineering constraints of a PET system based on avalanche photodiode (APD) detectors have been described in a previous report. Here, the authors present the initial results obtained with the Sherbrooke APD-PET scanner, a very high spatial resolution device designed for dynamic imaging of small and medium-sized laboratory animals such as rats, cats, rabbits and small monkeys. Its physical performance has been evaluated in terms of resolution, sensitivity, count rate, random and scatter fractions, contrast and relative activity recovery as a function of object size. The capabilities of the scanner for biomedical research applications have been demonstrated using phantom and animal studies.

[1]  T. Yamashita,et al.  A high resolution PET for animal studies , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[2]  R Lecomte,et al.  High-resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Roger Lecomte,et al.  Tuning of avalanche photodiode PET camera , 1992 .

[4]  K Wienhard,et al.  The ECAT EXACT HR: Performance of a New High Resolution Positron Scanner , 1994, Journal of computer assisted tomography.

[5]  Roger Lecomte,et al.  Design and engineering aspects of a high resolution positron tomograph for small animal imaging , 1994 .

[6]  P Bruyndonckx,et al.  A fully 3D small PET scanner. , 1992, Physics in medicine and biology.

[7]  M E Phelps,et al.  Design features and performance of a PET system for animal research. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  F. Daghighian,et al.  Design considerations of an animal PET scanner utilizing ESO scintillators and position sensitive PMTs , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.

[9]  Y Yonekura,et al.  Noninvasive measurement of cerebral blood flow and glucose metabolic rate in the rat with high-resolution animal positron emission tomography (PET): a novel in vivo approach for assessing drug action in the brains of small animals. , 1995, Biological & pharmaceutical bulletin.

[10]  R. Myers,et al.  Quantitation of Carbon‐11‐labeled raclopride in rat striatum using positron emission tomography , 1992, Synapse.

[11]  R. Jain,et al.  Imaging of activated natural killer cells in mice by positron emission tomography: preferential uptake in tumors. , 1993, Cancer research.

[12]  W. Heiss,et al.  High-resolution PET in cats: application of a clinical camera to experimental studies. , 1995, Journal of Nuclear Medicine.

[13]  T J Spinks,et al.  The design and physical characteristics of a small animal positron emission tomograph. , 1995, Physics in medicine and biology.

[14]  Simon R. Cherry,et al.  Development of continuous detectors for a high resolution animal PET system , 1995 .

[15]  E. Hoffman,et al.  Performance standards in positron emission tomography. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  R Lecomte,et al.  Assessment of scatter components in high-resolution PET: correction by nonstationary convolution subtraction. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  L. Widén,et al.  Journal of Cerebral Blood Flow and Metabolism Rapid Feasibility Studies of Tracers for Positron Emission Tomography: High-resolution Pet in Small Animals with Kinetic Analysis , 2022 .