Systematic Design and Modeling of a OTA-C Filter for Portable ECG Detection

This study presents a systematic design of the fully differential operational transconductance amplifier-C (OTA-C) filter for a heart activities detection apparatus. Since the linearity and noise of the filter is dependent on the building cell, a precise behavioral model for the real OTA circuit is created. To reduce the influence of coefficient sensitivity and maintain an undistorted biosignal, a fifth-order ladder-type lowpass Butterworth is employed. Based on this topology, a chip fabricated in a 0.18- mum CMOS process is simulated and measured to validate the system estimation. Since the battery life and the integration with the low-voltage digital processor are the most critical requirement for the portable diagnosis device, the OTA-based circuit is operated in the subthreshold region to save power under the supply voltage of 1V. Measurement results show that this low-voltage and low-power filter possesses the HD3 of -48.9 dB, dynamic range (DR) of 50 dB, and power consumption of 453 nW. Therefore, the OTA-C filter can be adopted to eliminate the out-of-band interference of the electrocardiogram (ECG) whose signal bandwidth is located within 250 Hz.

[1]  M. Ismail,et al.  Enhanced analog "yields" cost-effective systems-on-chip , 1999 .

[2]  Edgar Sanchez-Sinencio,et al.  Transconductance amplifier structures with very small transconductances: a comparative design approach , 2002 .

[3]  Kamran Eshraghian,et al.  SoC Emerging Technologies , 2006, Proceedings of the IEEE.

[4]  Andrea Baschirotto,et al.  A 1-/spl mu/A front end for pacemaker atrial sensing channels with early sensing capability , 2003, IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing.

[5]  Slawomir Koziel,et al.  Design of highly linear tunable CMOS OTA for continuous-time filters , 2002 .

[6]  Juha Kostamovaara,et al.  A 1-V analog CMOS front-end for detecting QRS complexes in a cardiac signal , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[7]  J. Fellrath,et al.  CMOS analog integrated circuits based on weak inversion operations , 1977 .

[8]  A. Neviani,et al.  A 1µA front-end for pacemaker atrial sensing channels , 2001 .

[9]  Dietmar Schroeder,et al.  Universal application-specific integrated circuit for bioelectric data acquisition. , 2002, Medical engineering & physics.

[10]  Joseph D. Bronzino,et al.  The Biomedical Engineering Handbook , 1995 .

[11]  Franco Maloberti,et al.  A 60-dB dynamic-range CMOS sixth-order 2.4-Hz low-pass filter for medical applications , 2000 .

[12]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[13]  Rahul Sarpeshkar,et al.  A practical micropower programmable bandpass filter for use in bionic ears , 2003, IEEE J. Solid State Circuits.

[14]  Yong Ping Xu,et al.  A CMOS Continuous-Time Low-Pass Notch Filter for EEG Systems , 2005 .

[15]  Nor Hisham Hamid,et al.  Time-Domain Modeling of Low-Frequency Noise in Deep-Submicrometer MOSFET , 2008, IEEE Transactions on Circuits and Systems I: Regular Papers.

[16]  Michiel Steyaert,et al.  A large-signal very low-distortion transconductor for high-frequency continuous-time filters , 1991 .

[17]  R. Ludwig,et al.  Crossroads for mixed-signal chips , 2002 .

[18]  P. K. Chan,et al.  A CMOS analog front-end IC for portable EEG/ECG monitoring applications , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[19]  L. Wong,et al.  A very low power CMOS mixed-signal IC for implantable pacemaker applications , 2004, 2004 IEEE International Solid-State Circuits Conference (IEEE Cat. No.04CH37519).

[20]  Kenneth R. Laker,et al.  Design of analog integrated circuits and systems , 1994 .

[21]  Y. Tsividis Operation and modeling of the MOS transistor , 1987 .

[22]  E. Rodriguez-Villegas,et al.  A 1.25-V micropower Gm-C filter based on FGMOS transistors operating in weak inversion , 2004, IEEE Journal of Solid-State Circuits.