A realistic volume conductor model of the neonatal head: Methods, challenges and applications

Developing a realistic volume conductor head model is an important step towards a non-invasive investigation of neuro-electrical activity in the brain. For adults, different volume conductor head models have been designed and successfully used for electroencephalography (EEG) source analysis. However, creating appropriate neonatal volume conductor head model for EEG source analysis is a challenging task mainly due to insufficient knowledge of head tissue conductivities and complex anatomy of the developing newborn brain. In this work, we present a pipeline for modeling a realistic volume conductor model of the neonatal head, where we address the modeling challenges and propose our solutions. We also discuss the use of our realistic volume conductor head model for neonatal EEG source analysis.

[1]  David R. Wozny,et al.  The electrical conductivity of human cerebrospinal fluid at body temperature , 1997, IEEE Transactions on Biomedical Engineering.

[2]  J. Pernier,et al.  A systematic evaluation of the spherical model accuracy in EEG dipole localization. , 1997, Electroencephalography and clinical neurophysiology.

[3]  Alan C. Evans,et al.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data , 1998, IEEE Transactions on Medical Imaging.

[4]  T Oostendorp,et al.  Interictal spike localization using a standard realistic head model: simulations and analysis of clinical data , 1999, Clinical Neurophysiology.

[5]  Thom F. Oostendorp,et al.  The conductivity of the human skull: results of in vivo and in vitro measurements , 2000, IEEE Transactions on Biomedical Engineering.

[6]  David R. Haynor,et al.  Nonrigid multimodality image registration , 2001, SPIE Medical Imaging.

[7]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[8]  P. W. Murray Field calculations in the head of a newborn infant and their application to the interpretation of transcephalic impedance measurements , 1981, Medical and Biological Engineering and Computing.

[9]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[10]  A. Aarabi,et al.  High‐resolution electroencephalography and source localization in neonates , 2008, Human brain mapping.

[11]  M. Cook,et al.  EEG source localization in focal epilepsy: Where are we now? , 2008, Epilepsia.

[12]  Simon K. Warfield,et al.  Automatic segmentation of newborn brain MRI , 2009, NeuroImage.

[13]  E. Vansteenkiste,et al.  Brain volume segmentation in newborn infants using multi-modal MRI with a low inter-slice resolution , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[14]  Ewout Vansteenkiste,et al.  T1- and T2-weighted spatially constrained fuzzy c-means clustering for brain MRI segmentation , 2010, Medical Imaging.

[15]  Fabrizio Esposito,et al.  Realistic and Spherical Head Modeling for EEG Forward Problem Solution: A Comparative Cortex-Based Analysis , 2010, Comput. Intell. Neurosci..

[16]  Dinggang Shen,et al.  CENTS: Cortical enhanced neonatal tissue segmentation , 2011, Human brain mapping.

[17]  R. Sadleir,et al.  The conductivity of neonatal piglet skulls. , 2011, Physiological measurement.

[18]  S. Huffel,et al.  Relationship of EEG sources of neonatal seizures to acute perinatal brain lesions seen on MRI: A pilot study , 2013, Human brain mapping.