Optimization of Undersampling Parameters for 3D Intracranial Compressed Sensing MR Angiography at 7 Tesla

Purpose: 3D Time-of-flight (TOF) MR Angiography (MRA) can accurately visualize the intracranial vasculature, but is limited by long acquisition times. Compressed sensing (CS) reconstruction can be used to substantially accelerate acquisitions. The quality of those reconstructions depends on the undersampling patterns used in the acquisitions. In this work, optimized sets of undersampling parameters using various acceleration factors for Cartesian 3D TOF-MRA are established. Methods: Fully-sampled datasets acquired at 7T were retrospectively undersampled using variable-density Poisson-disk sampling with various autocalibration region sizes, polynomial orders, and acceleration factors. The accuracy of reconstructions from the different undersampled datasets was assessed using the vessel-masked structural similarity index. Results were compared for four imaging volumes, acquired from two different subjects. Optimized undersampling parameters were validated using additional prospectively undersampled datasets. Results: For all acceleration factors, using a fully-sampled calibration area of 12×12 k-space lines and a polynomial order of around 2-2.4 resulted in the highest image quality. The importance of sampling parameter optimization was found to increase for higher acceleration factors. The results were consistent across resolutions and regions of interest with vessels of varying sizes and tortuosity. In prospectively undersampled acquisitions, using optimized undersampling parameters resulted in a 7.2% increase in the number of visible small vessels at R = 7.2. Conclusion: The image quality of CS TOF-MRA can be improved by appropriate choice of undersampling parameters. The optimized sets of parameters are independent of the acceleration factor.

[1]  Marc Teboulle,et al.  A fast Iterative Shrinkage-Thresholding Algorithm with application to wavelet-based image deblurring , 2009, 2009 IEEE International Conference on Acoustics, Speech and Signal Processing.

[2]  A Practical Under-Sampling Pattern for Compressed Sensing MRI , 2015 .

[3]  Shigeru Suzuki,et al.  Undersampling patterns in k-space for compressed sensing MRI using two-dimensional Cartesian sampling , 2018, Radiological Physics and Technology.

[4]  Mark E Ladd,et al.  Time-of-Flight Magnetic Resonance Angiography at 7 T Using Venous Saturation Pulses With Reduced Flip Angles , 2012, Investigative radiology.

[5]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[6]  A. Macovski,et al.  Variable-rate selective excitation , 1988 .

[7]  P. Speier,et al.  Clinical Evaluation of Highly Accelerated Compressed Sensing Time-of-Flight MR Angiography for Intracranial Arterial Stenosis , 2018, American Journal of Neuroradiology.

[8]  M. Yadollahi,et al.  Diagnostic Accuracy of Magnetic Resonance Angiography for Detection of Intracranial Aneurysms in Patients with Acute Subarachnoid Hemorrhage; A Comparison to Digital Subtraction Angiography. , 2013, Bulletin of emergency and trauma.

[9]  Nicole Seiberlich,et al.  Parallel MR imaging , 2012, Journal of magnetic resonance imaging : JMRI.

[10]  Christoph Forman,et al.  High resolution time-of-flight MR-angiography at 7 T exploiting VERSE saturation, compressed sensing and segmentation. , 2019, Magnetic resonance imaging.

[11]  Josef Pfeuffer,et al.  Seven-Tesla Time-of-Flight Angiography Using a 16-Channel Parallel Transmit System With Power-Constrained 3-dimensional Spoke Radiofrequency Pulse Design , 2014, Investigative radiology.

[12]  S. Greenberg,et al.  Small vessels, big problems. , 2006, The New England journal of medicine.

[13]  Jeroen Hendrikse,et al.  Noninvasive Depiction of the Lenticulostriate Arteries with Time-of-Flight MR Angiography at 7.0 T , 2008, Cerebrovascular Diseases.

[14]  Kieren Grant Hollingsworth,et al.  Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction , 2015, Physics in medicine and biology.

[15]  Toshiyuki Tanaka,et al.  Optimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception? , 2016, PloS one.

[16]  Johannes T Heverhagen,et al.  Time-of-Flight Magnetic Resonance Angiography at 7 Tesla , 2008, Investigative radiology.

[17]  K. Fountas,et al.  The Role of 3 Tesla MRA in the Detection of Intracranial Aneurysms , 2012, International journal of vascular medicine.

[18]  Nathan Murtha,et al.  Characterizing Dynamic MRI Using Objective Image Quality Metrics , 2017 .

[19]  Michael Elad,et al.  ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA , 2014, Magnetic resonance in medicine.

[20]  Martin R Prince,et al.  3D contrast‐enhanced MR angiography , 2007, Journal of magnetic resonance imaging : JMRI.

[21]  Michael Bock,et al.  Contrast enhancement in TOF cerebral angiography at 7 T using saturation and MT pulses under SAR constraints: Impact of VERSE and sparse pulses , 2012, Magnetic resonance in medicine.

[22]  T. Hashimoto,et al.  Statistical optimum 2D random sampling for Compressed Sensing MRI , 2018, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC).

[23]  James Sayre,et al.  High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography (CE-MRA) using compressed sensing with magnitude image subtraction , 2013, Journal of Cardiovascular Magnetic Resonance.

[24]  Kaori Togashi,et al.  Magnetic resonance angiography with compressed sensing: An evaluation of moyamoya disease , 2018, PloS one.

[25]  D L Parker,et al.  MR angiography by multiple thin slab 3D acquisition , 1991, Magnetic resonance in medicine.

[26]  Michaela Schmidt,et al.  Highly undersampled contrast‐enhanced MRA with iterative reconstruction: Integration in a clinical setting , 2015, Magnetic resonance in medicine.

[27]  M. Uecker,et al.  Accelerated whole‐heart MR angiography using a variable‐density poisson‐disc undersampling pattern and compressed sensing reconstruction , 2018, Magnetic resonance in medicine.

[28]  Julien Milles,et al.  Quantitative evaluation of Compressed Sensing in MRI: Application to 7T time-of-flight angiography , 2010, Proceedings of the 10th IEEE International Conference on Information Technology and Applications in Biomedicine.

[29]  J. Gillard,et al.  MR Angiography and Imaging for the Evaluation of Middle Cerebral Artery Atherosclerotic Disease , 2012, American Journal of Neuroradiology.