A Time-Resolved CMOS Image Sensor With Draining-Only Modulation Pixels for Fluorescence Lifetime Imaging

This paper presents a time-resolved CMOS image sensor with draining-only modulation (DOM) pixels, for time-domain fluorescence lifetime imaging. In the DOM pixels using a pinned photodiode (PPD) technology, a time-windowed signal charge transfer from a PPD to a pinned storage diode (PSD) is controlled by a draining gate only, without a transfer gate between the two diodes. This structure allows a potential barrierless and trapless charge transfer from the PPD to the PSD. A 256 × 256 pixel time-resolved CMOS imager with 7.5 × 7.5 μm2 DOM pixels has been implemented using 0.18-μm CMOS image sensor process technology with PPD option. The prototype demonstrates high sensitivity for weak signal of less than one electron per light pulse and accurate measurement of fluorescence decay process with subnanosecond time resolution.

[1]  J. Hynecek,et al.  Virtual phase technology: A new approach to fabrication of large-area CCD's , 1981, IEEE Transactions on Electron Devices.

[2]  Jan Siegel,et al.  Biomedical Applications of Fluorescence Lifetime Imaging , 2002 .

[3]  Pierre Magnan,et al.  High Speed Dual Port Pinned-photodiode for Time-Of-Flight Imaging , 2009 .

[4]  R. Lange,et al.  Solid-state time-of-flight range camera , 2001 .

[5]  S. Kawahito,et al.  A CMOS Image Sensor With In-Pixel Two-Stage Charge Transfer for Fluorescence Lifetime Imaging , 2009, IEEE Transactions on Electron Devices.

[6]  Kawahito Shoji,et al.  Buried Photodiode Structure for High-Speed Charge Transfer , 2008 .

[7]  K. Arai,et al.  No image lag photodiode structure in the interline CCD image sensor , 1982, 1982 International Electron Devices Meeting.

[8]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[9]  Tsutomu Araki,et al.  Finding of Optimal Calcium Ion Probes for Fluorescence Lifetime Measurement , 2005 .

[10]  Franco Zappa,et al.  3D ranging with a single-photon imaging array , 2011, Electronic Imaging.

[11]  William R. Ware,et al.  Deconvolution of fluorescence decay curves. A critical comparison of techniques , 1979 .

[12]  Alberto Tosi,et al.  Linear arrays of single-photon detectors for photon counting and timing , 2011, Electronic Imaging.

[13]  K Yasutomi,et al.  A Two-Stage Charge Transfer Active Pixel CMOS Image Sensor With Low-Noise Global Shuttering and a Dual-Shuttering Mode , 2011, IEEE Transactions on Electron Devices.

[14]  Brian Herman,et al.  Fluorescence imaging spectroscopy and microscopy , 1996 .

[15]  E. Charbon,et al.  A Time-Gated 128x128 CMOS SPAD Array for on-Chip Fluorescence Detection , 2011 .

[16]  S. Kawahito,et al.  Noise analysis of high-gain, low-noise column readout circuits for CMOS image sensors , 2004, IEEE Transactions on Electron Devices.