submitter : Influence of the cusp field on the plasma parameters of the Linac4 H− ion source

When the H− ion source of CERN’s Linac4 is operated in volume mode, a maximum of the extracted current is obtained at varying RF power. The power required for this maximum and its absolute value is strongly influenced by the cusp magnets installed at the source for electron confinement: without magnets, 15−20 mA are typically obtained at 20 kW whereas with magnets a factor of two more power is needed and 25−30 mA are achieved. In order to access the reasons behind the peaked performance with varying RF power and for determining the influence of the cusp field on the discharge, optical emission spectroscopy (OES) measurements of the atomic Balmer series and of the molecular Fulcher transition have been carried out. In all investigated cases, the gas temperature of the discharge has been virtually equal to the ambient temperature as the short discharge pulse length of 500 µs is not long enough for considerable heavy particle heating. When no cusp magnets are installed, the plasma parameters evaluated with t...