In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses

BackgroundThe per-operative assessment of primary stem stability may help to improve the performance of total hip replacement. Vibration analysis methods have been successfully used to assess dental implant stability, to monitor fracture healing and to measure bone mechanical properties. The objective of the present study was to evaluate in vivo a vibration analysis-based endpoint criterion for the insertion of the stem by successive surgeon-controlled hammer blows.MethodsA protocol using a vibration analysis technique for the characterisation of the primary bone-prosthesis stability was tested in 83 patients receiving a custom-made, intra-operatively manufactured stem prosthesis. Two groups were studied: one (n = 30) with non cemented and one (n = 53) with partially cemented stem fixation. Frequency response functions of the stem-femur system corresponding to successive insertion stages were compared.ResultsThe correlation coefficient between the last two frequency response function curves was above 0.99 in 86.7% of the non cemented cases. Lower values of the final correlation coefficient and deviations in the frequency response pattern were associated with instability or impending bone fracture. In the cases with a partially cemented stem an important difference in frequency response function between the final stage of non cemented trial insertion and the final cemented stage was found in 84.9% of the cases. Furthermore, the frequency response function varied with the degree of cement curing.ConclusionThe frequency response function change provides reliable information regarding the stability evolution of the stem-femur system during the insertion. The protocol described in this paper can be used to accurately detect the insertion end point and to reduce the risk for intra-operative fracture.

[1]  G Van der Perre,et al.  On the mechanical resonances of a human tibia in vitro. , 1983, Journal of biomechanics.

[2]  G Van der Perre,et al.  Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. , 1996, Journal of biomechanics.

[3]  Georges Van der Perre,et al.  Analysis of the fixation quality of cementless hip prostheses using a vibrational technique , 2004 .

[4]  Gang Qi,et al.  How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening? , 2003, Clinical biomechanics.

[5]  A. Georgiou,et al.  Accurate diagnosis of hip prosthesis loosening using a vibrational technique. , 2001, Clinical biomechanics.

[6]  L Sennerby,et al.  Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. , 1997, Clinical oral implants research.

[7]  F. Duck,et al.  Bone vibration measurement using ultrasound: application to detection of hip prosthesis loosening. , 2008, Medical engineering & physics.

[8]  G F McCoy,et al.  The Differentiation of Loose and Secure Femoral Implants in Total Hip Replacement Using a Vibrational Technique: An Anatomical and Pilot Clinical Study , 1989, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  P. D. Wilson,et al.  Revision total hip arthroplasty. , 1982, Clinical orthopaedics and related research.

[10]  G Van der Perre,et al.  Identification of in-vivo vibration modes of human tibiae by modal analysis. , 1983, Journal of biomechanical engineering.

[11]  C. Bünger,et al.  Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  G Van der Perre,et al.  The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model. , 1993, Journal of biomechanics.

[13]  M Mulier,et al.  Detection of the insertion end point of cementless hip prostheses using the comparison between successive frequency response functions. , 2008, Journal of applied biomaterials & biomechanics : JABB.

[14]  Paul Sas,et al.  Modal Analysis Theory and Testing , 2005 .

[15]  A Bezerianos,et al.  Monitoring of fracture healing by lateral and axial vibration analysis. , 1990, Journal of biomechanics.

[16]  G Lowet,et al.  In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. , 1996, Bone.

[17]  B Mjöberg,et al.  The theory of early loosening of hip prostheses. , 1997, Orthopedics.

[18]  D W Murray,et al.  Long-term comparison of Charnley and Stanmore design total hip replacements. , 1996, The Journal of bone and joint surgery. British volume.

[19]  Y. Nakatsuchi,et al.  Assessment of fracture healing in the tibia using the impulse response method. , 1996, Journal of orthopaedic trauma.

[20]  Angelo Cappello,et al.  Intra-operative evaluation of cementless hip implant stability: a prototype device based on vibration analysis. , 2007, Medical engineering & physics.

[21]  B. Masri,et al.  Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. , 2004, The Journal of bone and joint surgery. American volume.

[22]  I. Jonkers,et al.  Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups , 2007, Archives of Orthopaedic and Trauma Surgery.

[23]  M Mulier,et al.  A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure. , 1989, Clinical orthopaedics and related research.