A computer simulation for evaluating dual-energy contrast-enhanced breast tomosynthesis

Previous studies have suggested that iodine contrast-enhanced breast tomosynthesis can be helpful in the characterization of suspicious abnormalities. Dual-energy, contrast-enhanced breast tomosynthesis involves acquiring low- and high-energy acquisitions after the administration of the contrast agent, and therefore can simplify the procedure and reduce the effect of patient motion. In this study, a computer simulation is developed for use in investigating optimal parameters for dual-energy, contrast-enhanced breast tomosynthesis. The simulation allows for the selection of various polyenergetic x-ray spectra and x-ray filters, and models x-ray transport through a voxelized breast phantom, as well as signal and noise propagation through an indirect CsI based imager. A compressed breast phantom that models the non-uniform parenchymal structure of the breast is used. Irregular lesions were simulated by using a stochastic growth algorithm. Simulations of dual-energy subtraction, contrast-enhanced breast tomosynthesis show that using x-ray filters to form quasi-monochromatic high- and low-energy spectra above and below the iodine K-edge can substantially reduce background structure, and increase lesion conspicuity as compared to single shot contrast-enhanced BT.

[1]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[2]  J. Boone,et al.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. , 1999, Radiology.

[3]  J. Folkman,et al.  The role of angiogenesis in tumor growth. , 1992, Seminars in cancer biology.

[4]  Yasumasa Nishimura,et al.  Dynamic multidetector CT of breast tumors: diagnostic features and comparison with conventional techniques. , 2003, AJR. American journal of roentgenology.

[5]  J. Fessler Statistical Image Reconstruction Methods for Transmission Tomography , 2000 .

[6]  Stephen J. Glick,et al.  Computer simulation of CT mammography using a flat-panel imager , 2003, SPIE Medical Imaging.

[7]  Ian Shaw,et al.  Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector , 2005, SPIE Medical Imaging.

[8]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[9]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[10]  Arthur E. Burgess,et al.  Producing lesions for hybrid mammograms: extracted tumors and simulated microcalcifications , 1999, Medical Imaging.

[11]  Andrew D. A. Maidment,et al.  Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation. , 2002, Medical physics.

[12]  Ann-Katherine Carton,et al.  Quantification for contrast-enhanced digital breast tomosynthesis , 2006, SPIE Medical Imaging.

[13]  P. C. Johns,et al.  X-ray characterisation of normal and neoplastic breast tissues. , 1987, Physics in medicine and biology.