Risk Factor Analysis of Bone Cement Leakage for Polymethylmethacrylate-Augmented Cannulated Pedicle Screw Fixation in Spinal Degenerative Diseases

Background We investigated the risk factors of cement leakage (CL) for polymethylmethacrylate-augmented cannulated pedicle screw (CPS) in spinal degenerative diseases and provided technical guidance for clinical surgery. Methods This study enrolled 276 patients with spinal degenerative disease and osteoporosis who were augmented using CPSs (835 screws in total) from May 2011 to June 2018 in our hospital. The patients' age, sex, bone mineral density (BMD), diagnosis, augmented positions, number of CPS implanted, and CL during surgery were recorded. CL was observed by postoperative computed tomography (CT) and was classified by Yeom typing. Results A total of 74 (8.9%) CPSs in 64 patients leaked (23.2%), with 65 (87.83%), 3 (4.05%), and 6 (8.11%) screws showing Types S, B, and C leakage, respectively. CL was significantly correlated with the number and position of screws (P < 0.05), but not with sex, age, and BMD (P > 0.05). The position, number of CPSs, fracture, degenerative scoliosis, ankylosing spondylitis, and revision surgery were risk factors for CL (P < 0.05). Augmentation of the thoracic vertebral body, fracture, and ankylosing spondylitis were independent risk factors for Type S. Augmentation of the lumbar vertebral body, lumbar disc herniation, and lumbar spondylolisthesis were independent risk factors for Type B (P < 0.05). Conclusions CL has a high incidence in clinical practice. To avoid serious complications, high-risk factors for leakage should be addressed. Particularly, it is necessary to develop alternative solutions for the lack of holding force of internal fixation caused by CL during surgery.

[1]  C. Niu,et al.  Risk factors of neurological deficit and pulmonary cement embolism after percutaneous vertebroplasty , 2019, Journal of Orthopaedic Surgery and Research.

[2]  Rajesh Kumar,et al.  Preparation and Evaluation of Bioactivity of Porous Bioglass Tablets for Bone Tissue Regeneration , 2019, SciMedicine Journal.

[3]  D. Liang,et al.  The cement leakage in cement-augmented pedicle screw instrumentation in degenerative lumbosacral diseases: a retrospective analysis of 202 cases and 950 augmented pedicle screws , 2019, European Spine Journal.

[4]  M. Amling,et al.  A retrospective analysis of bone mineral status in patients requiring spinal surgery , 2018, BMC Musculoskeletal Disorders.

[5]  M. Martín-Fernández,et al.  Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality. , 2017, The spine journal : official journal of the North American Spine Society.

[6]  I. Janssen,et al.  Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. , 2017, The spine journal : official journal of the North American Spine Society.

[7]  S. Mlyavykh,et al.  The Potential Impact of Venobasillar System Morphology and Applied Technique on Epidural Cement Leakage with Percutaneous Vertebroplasty. , 2016, Pain physician.

[8]  Jianting Chen,et al.  Risk factors for bone cement leakage in percutaneous vertebroplasty: a retrospective study of four hundred and eighty five patients , 2016, International Orthopaedics.

[9]  Ioan A. Lina,et al.  The biomechanics of pedicle screw augmentation with cement. , 2015, The spine journal : official journal of the North American Spine Society.

[10]  F. Luo,et al.  Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients , 2015, Clinics.

[11]  Hui-lin Yang,et al.  Percutaneous augmented instrumentation of unstable thoracolumbar burst fractures: our experience in preventing cement leakage , 2012, European Spine Journal.

[12]  H. Tsai,et al.  Pedicle screw loosening in dynamic stabilization: incidence, risk, and outcome in 126 patients. , 2011, Neurosurgical focus.

[13]  Chien-Lin Liu,et al.  Polymethylmethacrylate augmentation of the pedicle screw: the cement distribution in the vertebral body , 2011, European Spine Journal.

[14]  W. Hutton,et al.  Pedicle Screw Augmentation With Polyethylene Tape: A Biomechanical Study in the Osteoporotic Thoracolumbar Spine , 2010, Journal of spinal disorders & techniques.

[15]  A. V. van Erkel,et al.  The Value of Routinely Performing a Bone Biopsy During Percutaneous Vertebroplasty in Treatment of Osteoporotic Vertebral Compression Fractures , 2009, Spine.

[16]  S. Ferguson,et al.  Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies , 2006, Spine.

[17]  R. Schmidt,et al.  Cement leakage during vertebroplasty: an underestimated problem? , 2005, European Spine Journal.

[18]  C. K. Lee,et al.  Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. , 2003, The Journal of bone and joint surgery. British volume.

[19]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[20]  Claus Christiansen,et al.  Diagnosis of Osteoporosis , 1992, Southern medical journal.