Interventional and intraoperative magnetic resonance imaging.

The goal of the Image Guided Therapy Program, as the name implies, is to develop the use of imaging to guide minimally invasive therapy. The program combines interventional and intraoperative magnetic resonance imaging (MRI) with high-performance computing and novel therapeutic devices. In clinical practice the multidisciplinary program provides for the investigation of a wide range of interventional and surgical procedures. The Signa SP 0.5 T superconducting MRI system (GE Medical Systems, Milwaukee, WI) has a 56-cm-wide vertical gap, allowing access to the patient and permitting the execution of interactive MRI-guided procedures. This system is integrated with an optical tracking system and utilizes flexible surface coils and MRI-compatible displays to facilitate procedures. Images are obtained with routine pulse sequences. Nearly real-time imaging, with fast gradient-recalled echo sequences, may be acquired at a rate of one image every 1.5 s with interactive image plane selection. Since 1994, more than 800 of these procedures, including various percutaneous procedures and open surgeries, have been successfully performed at Brigham and Women's Hospital (Boston, MA).

[1]  E Grabbe,et al.  MR imaging-guided breast intervention: experience with two systems. , 1995, Radiology.

[2]  R Kikinis,et al.  Intraoperative MR imaging guidance for intracranial neurosurgery: experience with the first 200 cases. , 1999, Radiology.

[3]  David T. Gering,et al.  A system for surgical planning and guidance using image fusion and interventional MR , 1999 .

[4]  Thomas Kahn,et al.  MRI‐Guided Laser‐Induced Interstitial Thermotherapy of Cerebral Neoplasms , 1994, Journal of computer assisted tomography.

[5]  L P Panych,et al.  A dynamically adaptive imaging algorithm for wavelet‐encoded MRI , 1994, Magnetic resonance in medicine.

[6]  Patricio C. Gargollo,et al.  Intraoperative magnetic resonance imaging: considerations for the operating room of the future , 2001, Journal of Clinical Neuroscience.

[7]  D. Cheng,et al.  Fast-track cardiac surgery: economic implications in postoperative care. , 1998, Journal of cardiothoracic and vascular anesthesia.

[8]  R. Kikinis,et al.  Superconducting open-configuration MR imaging system for image-guided therapy. , 1995, Radiology.

[9]  W Kucharczyk,et al.  Do the benefits of image guidance in neurosurgery justify the costs? From stereotaxy to intraoperative MR. , 1997, AJNR. American journal of neuroradiology.

[10]  J. Kettenbach,et al.  Monitoring and visualization techniques for MR‐guided laser ablations in an open MR system , 1998, Journal of magnetic resonance imaging : JMRI.

[11]  C. Matula,et al.  Intraoperative computed tomography guided neuronavigation: concepts, efficiency, and work flow. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[12]  D. Kondziolka,et al.  Intraoperative imaging of the brain. , 1996, Stereotactic and functional neurosurgery.

[13]  W. Hall,et al.  Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery. , 2000, Neurosurgery.

[14]  Donald W. Kormos,et al.  Glioma Resection in a Shared-resource Magnetic Resonance Operating Room after Optimal Image-guided Frameless Stereotactic Resection , 2001, Neurosurgery.

[15]  G. Casola,et al.  A wire-sheath system for MR-guided biopsy and drainage: laboratory studies and experience in 10 patients. , 1988, AJR. American journal of roentgenology.

[16]  J. Nazzaro,et al.  The role of surgery in the management of supratentorial intermediate and high-grade astrocytomas in adults. , 1990, Journal of neurosurgery.

[17]  J. Mühling,et al.  Computer assisted oral and maxillofacial surgery--a review and an assessment of technology. , 2001, International journal of oral and maxillofacial surgery.

[18]  Nobuhiko Hata,et al.  Image guided neurosurgery: visualization of brain shift , 1999 .

[19]  K Farahani,et al.  Effect of field strength on susceptibility artifacts in magnetic resonance imaging. , 1990, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[20]  Alastair J. Martin,et al.  Comparison of Stereotactic Brain Biopsy to Interventional Magnetic-Resonance-Imaging-Guided Brain Biopsy , 2000, Stereotactic and Functional Neurosurgery.

[21]  W. Kucharczyk,et al.  A New Frontier: Magnetic Resonance Imaging-Operating Room , 2000, Journal of neurosurgical anesthesiology.

[22]  B P Griffith,et al.  Resource utilization for minimally invasive direct and standard coronary artery bypass grafting. , 1997, The Annals of thoracic surgery.

[23]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.

[24]  P. Matthews,et al.  The future of magnetic resonance-based techniques in neurology. , 2001, European journal of neurology.

[25]  F. Jolesz,et al.  Functional MRI of the lumbar spine in erect position in a superconducting open‐configuration MR system: Preliminary results , 1998, Journal of magnetic resonance imaging : JMRI.

[26]  D. Kacher,et al.  Intraoperative MR systems. Midfield approaches. , 2001, Neuroimaging clinics of North America.

[27]  H Requardt,et al.  Prototype Breast Coil for MR‐Guided Needle Localization , 1994, Journal of computer assisted tomography.

[28]  M D Schnall,et al.  Staging of suspected breast cancer: effect of MR imaging and MR-guided biopsy. , 1995, Radiology.

[29]  O. Witte,et al.  Quantitative imaging study of extent of surgical resection and prognosis of malignant astrocytomas. , 1997, Neurosurgery.

[30]  G. Glover,et al.  Breast lesion localization: a freehand, interactive MR imaging-guided technique. , 1998, Radiology.

[31]  P Boesiger,et al.  Biopsy needle susceptibility artifacts , 1996, Magnetic resonance in medicine.

[32]  J S Lewin,et al.  Pulse sequences for interventional magnetic resonance imaging. , 2000, Topics in magnetic resonance imaging : TMRI.

[33]  M. Gervin,et al.  Moveable intraoperative magnetic resonance imaging systems in the OR. , 1999, AORN journal.

[34]  F. Jolesz,et al.  MR imaging of the female pelvic floor in the supine and upright positions , 1996, Journal of magnetic resonance imaging : JMRI.

[35]  S. Silverman,et al.  Interactive MR‐guided percutaneous nephrostomy , 1998, Journal of magnetic resonance imaging : JMRI.

[36]  G. Sutherland,et al.  Advances in mobile intraoperative magnetic resonance imaging. , 2000, Neurosurgery.

[37]  O Lucidarme,et al.  Nonpalpable breast tumors: diagnosis with contrast-enhanced subtraction dynamic MR imaging. , 1994, Radiology.

[38]  F G Shellock,et al.  Quantification of patellar tracking using kinematic MRI , 1998, Journal of magnetic resonance imaging : JMRI.

[39]  J M Pruneda,et al.  MR imaging in the management before surgery of lobular carcinoma of the breast: correlation with pathology. , 1996, AJR. American journal of roentgenology.

[40]  F A Jolesz,et al.  Cost-effectiveness of image-guided surgery. , 1998, Academic radiology.

[41]  J. Debatin,et al.  Single‐loop coil concepts for intravascular magnetic resonance imaging , 1999, Magnetic resonance in medicine.

[42]  Research in interventional MR imaging: where do we go from here? , 1999, Academic radiology.

[43]  Thomas Moriarty,et al.  Evaluation of intracranial cysts by intraoperative MR , 1998, Journal of magnetic resonance imaging : JMRI.

[44]  W. Hall,et al.  Intraoperative MR systems. High-field approaches. , 2001, Neuroimaging clinics of North America.

[45]  Joachim Kettenbach,et al.  Laser-induced thermotherapy of cerebral neoplasia under MR tomographic control , 1998 .

[46]  G. Glover,et al.  Breast cancer: gadolinium-enhanced MR imaging with a 0.5-T open imager and three-point Dixon technique. , 1998, Radiology.

[47]  P. Black,et al.  Craniotomy for tumor treatment in an intraoperative magnetic resonance imaging unit. , 1999, Neurosurgery.

[48]  H. Weiss,et al.  [A technic of MRT-guided abdominal drainage with an open low-field magnet. Its feasibility and the initial results]. , 1996, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[49]  F A Jolesz,et al.  Focused US system for MR imaging-guided tumor ablation. , 1995, Radiology.

[50]  W. Hall The safety and efficacy of stereotactic biopsy for intracranial lesions , 1998, Cancer.

[51]  J S Lewin,et al.  Intraoperative magnetic resonance image guidance in neurosurgery , 2000, Journal of magnetic resonance imaging : JMRI.

[52]  René M. Botnar,et al.  Radio-frequency-induced thermoablation: monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment. , 1998, Radiology.

[53]  K Hynynen,et al.  Design and optimization of an aperiodic ultrasound phased array for intracavitary prostate thermal therapies. , 1996, Medical physics.

[54]  Nobuhiko Hata,et al.  A Volumetric Optical Flow Method for Measurement of Brain Deformation from Intraoperative Magnetic Resonance Images , 1999, MICCAI.

[55]  F. Jolesz Neurosurgical suite of the future. II. , 2001, Neuroimaging clinics of North America.

[56]  J. Debatin,et al.  Autoperfused balloon catheter for intravascular MR imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[57]  W. Hall,et al.  Optimizing brain tumor resection. High-field interventional MR imaging. , 2001, Neuroimaging clinics of North America.

[58]  A. D'Amico,et al.  Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer. , 1998, International journal of radiation oncology, biology, physics.

[59]  M Deimling,et al.  Malignant liver tumors treated with MR imaging-guided laser-induced thermotherapy: technique and prospective results. , 1995, Radiology.

[60]  G. Krishna,et al.  Anaesthetic considerations for magnetic resonance imaging. , 1994, Annals of the Academy of Medicine, Singapore.

[61]  D B Plewes,et al.  MR imaging of blood vessels with an intravascular coil , 1992, Journal of magnetic resonance imaging : JMRI.

[62]  M Heller,et al.  Patellar tracking patterns during active and passive knee extension: evaluation with motion-triggered cine MR imaging. , 1993, Radiology.

[63]  P A Bottomley,et al.  High resolution intravascular MRI and MRS by using a catheter receiver coil , 1996, Magnetic resonance in medicine.

[64]  J. Keltner,et al.  Magnetohydrodynamics of blood flow , 1990, Magnetic resonance in medicine.

[65]  F. Jolesz,et al.  Dynamically adaptive MRI with encoding by singular value decomposition , 1994, Magnetic resonance in medicine.

[66]  W. Hall,et al.  Intraoperative magnetic resonance imaging. , 2000, Topics in magnetic resonance imaging : TMRI.

[67]  E Kanal,et al.  Patient monitoring during clinical MR imaging. , 1992, Radiology.

[68]  N. Hopf,et al.  Basic principles and clinical applications of neuronavigation and intraoperative computed tomography. , 1998, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[69]  D I Hoult,et al.  The engineering of an interventional MRI with a movable 1.5 Tesla magnet , 2001, Journal of magnetic resonance imaging : JMRI.

[70]  John Y. K. Lee,et al.  Brain Surgery with Image Guidance: Current Recommendations Based on a 20-Year Assessment , 2001, Stereotactic and Functional Neurosurgery.

[71]  S. Jeffrey,et al.  The importance of the lumpectomy surgical margin status in long term results of breast conservation , 1995, Cancer.

[72]  J S Lewin,et al.  Intraoperative MR systems. Low-field approaches. , 2001, Neuroimaging clinics of North America.

[73]  A. Recht,et al.  The sequencing of chemotherapy and radiation therapy after conservative surgery for early-stage breast cancer. , 1996, The New England journal of medicine.

[74]  D. Burns,et al.  MRI-guided biopsy in inflammatory myopathy: initial results. , 1993, Magnetic resonance imaging.

[75]  F. Jolesz,et al.  Invited. Compatible instrumentation for intraoperative MRI: Expanding resources , 1998 .

[76]  Ogan Ocali,et al.  Intravascular magnetic resonance imaging using a loopless catheter antenna , 1997, Magnetic resonance in medicine.

[77]  R R Edelman,et al.  MR-guided aspiration biopsy: needle design and clinical trials. , 1986, Radiology.

[78]  D. Freifelder Physical Biochemistry: Applications to Biochemistry and Molecular Biology , 1976 .

[79]  R. Delamarter,et al.  MR parameters for imaging titanium spinal instrumentation. , 1997, Journal of spinal disorders.

[80]  J O Barentsz,et al.  Breast tumors: comparative accuracy of MR imaging relative to mammography and US for demonstrating extent. , 1995, Radiology.

[81]  F. Jolesz,et al.  Interactive MR-guided biopsy in an open-configuration MR imaging system. , 1995, Radiology.

[82]  F A Jolesz,et al.  Prototype miniature endoluminal MR imaging catheter. , 1993, Journal of vascular and interventional radiology : JVIR.

[83]  Derek L. G. Hill,et al.  Measurement of Intraoperative Brain Surface Deformation Under a Craniotomy , 1998, MICCAI.

[84]  P. Lauterbur,et al.  Principles of magnetic resonance imaging : a signal processing perspective , 1999 .

[85]  F. Jolesz,et al.  Legg-Calvé-Perthes disease: MR imaging evaluation during manual positioning of the hip--comparison with conventional arthrography. , 1999, Radiology.

[86]  S J Keens,et al.  Burns caused by ECG monitoring during MRI imaging , 1996, Anaesthesia.

[87]  R Kikinis,et al.  Magnetic resonance imaging therapy. Intraoperative MR imaging. , 1996, Neurosurgery clinics of North America.

[88]  F G Shellock,et al.  Patellofemoral joint: identification of abnormalities with active-movement, "unloaded" versus "loaded" kinematic MR imaging techniques. , 1993, Radiology.

[89]  C. Tempany,et al.  Open-configuration MR imaging, intervention, and surgery of the urinary tract. , 1998, The Urologic clinics of North America.

[90]  Lawrence P. Panych,et al.  Magnetic resonance imaging of interstitial laser photocoagulation , 1990, Photonics West - Lasers and Applications in Science and Engineering.

[91]  J. Rubin,et al.  Intraoperative US versus intraoperative MR imaging for guidance during intracranial neurosurgery. , 2000, Radiology.

[92]  F A Jolesz,et al.  MR monitoring during cryotherapy in the liver: Predictability of histologic outcome , 1993, Journal of magnetic resonance imaging : JMRI.

[93]  G T Gillies,et al.  Cost-efficacy of MR-guided neurointerventions. , 2001, Neuroimaging clinics of North America.

[94]  W. Eric L. Grimson,et al.  An Integrated Visualization System for Surgical Planning and Guidance Using Image Fusion and Interventional Imaging , 1999, MICCAI.

[95]  C. Nimsky,et al.  Quantification of, Visualization of, and Compensation for Brain Shift Using Intraoperative Magnetic Resonance Imaging , 2000, Neurosurgery.

[96]  W Kucharczyk,et al.  Brain tumor surgery with the Toronto open magnetic resonance imaging system: preliminary results for 36 patients and analysis of advantages, disadvantages, and future prospects. , 2000, Neurosurgery.

[97]  F. Jolesz Invited. Interventional and intraoperative MRI: A general overview of the field , 1998, Journal of magnetic resonance imaging : JMRI.

[98]  F A Jolesz,et al.  MR imaging of pelvic floor continence mechanisms in the supine and sitting positions. , 1998, AJR. American journal of roentgenology.

[99]  A Darzi,et al.  Interventional MR‐guided excisional biopsy of breast lesions , 1998, Journal of magnetic resonance imaging : JMRI.

[100]  F G Shellock,et al.  Kinematic MR imaging of the patellofemoral joint: comparison of passive positioning and active movement techniques. , 1992, Radiology.

[101]  L P Panych,et al.  Digital wavelet‐encoded MRI: A new wavelet‐encoding methodology , 1998, Journal of magnetic resonance imaging : JMRI.

[102]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[103]  F A Jolesz,et al.  Design and implementation of an interventional MR imaging suite. , 1997, AJR. American journal of roentgenology.

[104]  K. Hynynen,et al.  Magnetic resonance‐guided thermal surgery , 1993, Magnetic resonance in medicine.

[105]  C. Kremser,et al.  Metallic Artifacts in Magnetic Resonance Imaging of Patients With Spinal Fusion: A Comparison of Implant Materials and Imaging Sequences , 1998, Spine.

[106]  F A Jolesz,et al.  The operating room of the future. Report of the National Cancer Institute Workshop, "Imaging-Guided Stereotactic Tumor Diagnosis and Treatment". , 1992, Investigative radiology.

[107]  H. Berkenstadt,et al.  Novel, Compact, Intraoperative Magnetic Resonance Imaging-guided System for Conventional Neurosurgical Operating Rooms , 2001, Neurosurgery.

[108]  F. Shellock,et al.  Biopsy needles and devices: Assessment of ferromagnetism and artifacts during exposure to a 1.5‐T MR system , 1995, Journal of magnetic resonance imaging : JMRI.

[109]  C L Dumoulin,et al.  Real-time biplanar needle tracking for interventional MR imaging procedures. , 1995, Radiology.

[110]  F A Jolesz,et al.  Frameless Stereotactic Neurosurgery Using Intraoperative Magnetic Resonance Imaging: Stereotactic Brain Biopsy , 2000, Neurosurgery.