Real-Scenario Testing of an Active Phasor Data Concentrator

The privileged position of the Phasor Data Concentrator (PDC) in a synchrophasor-based monitoring system can be exploited to make this device the core of a distributed measurement architecture suitable for control and protection applications in power systems. Recent research work has introduced the concept of an active PDC able both to handle adaptively the latency of the input streams sent by the Phasor Measurement Units (PMUs) and to implement control logics based on the measurement values provided by the same PMUs. This paper presents and discusses experimental tests performed on a prototype of the active PDC, which manages, through the implemented advanced functionalities, a realistic number of PMUs located in two different geographical sites. First, we evaluate the PDC processing time as function of the input streams' number. Then, we investigate the feasibility and advantage of an optimised management of the PDC output streams in the presence of several PMUs characterised by different geographical location and data packet size.

[1]  Mario Paolone,et al.  Enhanced Interpolated-DFT for Synchrophasor Estimation in FPGAs: Theory, Implementation, and Validation of a PMU Prototype , 2014, IEEE Transactions on Instrumentation and Measurement.

[2]  Mario Paolone,et al.  Architecture and Experimental Validation of a Low-Latency Phasor Data Concentrator , 2018, IEEE Transactions on Smart Grid.

[3]  Luigi Vanfretti,et al.  The OpenPMU Platform for Open-Source Phasor Measurements , 2013, IEEE Transactions on Instrumentation and Measurement.

[4]  Paolo Attilio Pegoraro,et al.  An Active Phasor Data Concentrator Suitable for Control and Protection Applications , 2019, 2019 International Conference on Smart Grid Synchronized Measurements and Analytics (SGSMA).

[5]  Mladen Kezunovic,et al.  Synchrophasor reference algorithm for PMU Calibration System , 2016, 2016 IEEE/PES Transmission and Distribution Conference and Exposition (T&D).

[6]  Paolo Attilio Pegoraro,et al.  A Distributed PMU for Electrical Substations With Wireless Redundant Process Bus , 2015, IEEE Transactions on Instrumentation and Measurement.

[7]  Mario Paolone,et al.  Real-time state estimation of the EPFL-campus medium-voltage grid by using PMUs , 2015, 2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

[8]  Junqi Liu,et al.  A Fast and Accurate PMU Algorithm for P+M Class Measurement of Synchrophasor and Frequency , 2014, IEEE Transactions on Instrumentation and Measurement.

[9]  Dario Petri,et al.  Synchrophasor Estimators Accuracy: A Comparative Analysis , 2013, IEEE Transactions on Instrumentation and Measurement.

[10]  Davide Della Giustina,et al.  A distributed automation architecture for distribution networks, from design to implementation , 2017, Sustainable Energy, Grids and Networks.

[11]  Paolo Attilio Pegoraro,et al.  Low-Cost Implementation of an Active Phasor Data Concentrator for Smart Grid , 2018, 2018 Workshop on Metrology for Industry 4.0 and IoT.

[12]  G. M. Burt,et al.  P and M Class Phasor Measurement Unit Algorithms Using Adaptive Cascaded Filters , 2013, IEEE Transactions on Power Delivery.

[13]  Antonello Monti,et al.  Phasor measurement units and wide area monitoring systems , 2016 .