Oscillation analysis of a DFIG-based wind farm interfaced with LCC-HVDC

With the increasing capacity of wind farm, HVDC technology has become a promising transmission scheme for long distance transportation of large-scale wind power. However oscillation caused by this system will have a great influence on the security and stability of power system operation. In this paper, the oscillation of a doubly-fed induction generator (DFIG)-based wind farm interfaced with line commutated converter (LCC) based HVDC is discussed. Low-frequency oscillation and subsynchronous oscillation (SSO) are studied since these two oscillations are the particularly concerned oscillations in the stability study of power system in recent years. The model of a DFIG-based wind farm interconnected with LCC-HVDC is developed. The impact of drive train model’s structure and parameters on the oscillation characteristics is analyzed. Eigenvalue and participation factor analysis are used to identify the three main modes, which include controller mode, electromechanical mode, and shaft mode. The effects of DFIG controller’s parameters, wind speed and operating conditions of HVDC on those modes are studied. Electromagnetic transient simulations are performed to verify the results of the eigenvalue analysis.

[1]  Jingran Wang,et al.  Security value based expansion planning of power system with integration of large-scale wind power , 2012 .

[2]  Olimpo Anaya-Lara,et al.  Wind Energy Generation: Modelling and Control , 2009 .

[3]  Toshiaki Murata,et al.  Comparative study on transient stability analysis of wind turbine generator system using different drive train models , 2007 .

[4]  He Zhiyuan The Control Mode and Operating Performance of Nanhui VSC-HVDC Demonstration Project , 2012 .

[5]  A. Yazdani,et al.  Modeling and Stability Analysis of a DFIG-Based Wind-Power Generator Interfaced With a Series-Compensated Line , 2009, IEEE Transactions on Power Delivery.

[6]  U. D. Annakkage,et al.  A Procedure to Study Sub-Synchronous Interactions in Wind Integrated Power Systems , 2013, IEEE Transactions on Power Systems.

[7]  Geng Yang,et al.  Modeling, Analysis, and Control for the Rectifier of Hybrid HVdc Systems for DFIG-Based Wind Farms , 2011, IEEE Transactions on Energy Conversion.

[8]  S.M. Muyeen,et al.  Transient Stability Analysis of Wind Generator System with the Consideration of Multi-Mass Shaft Model , 2005, 2005 International Conference on Power Electronics and Drives Systems.

[9]  Tang Fan Sub-synchronous Resonance of Large-Scale Wind Farm , 2012 .

[10]  Bin Wu,et al.  Power Conversion and Control of Wind Energy Systems , 2011 .

[11]  Paul M. Anderson,et al.  Subsynchronous resonance in power systems , 1989 .

[12]  Bin Wu,et al.  Wind Generators and Modeling , 2011 .

[13]  Huang Bin,et al.  Transmission Capacity of Grid-Connecting Channel for the Second Phase of 3 GW Jiuquan Wind Power Base Project and Configuration of Its Reactive Power Compensation Equipments , 2013 .

[14]  He Zhiyuan Control Strategies of DFIG-based Wind Farm Grid Integration Using Modular Multilevel VSC-HVDC Technology , 2013 .

[15]  Garth D. Irwin,et al.  Sub-synchronous control interactions between type 3 wind turbines and series compensated AC transmission systems , 2011, 2011 IEEE Power and Energy Society General Meeting.

[16]  M. Negnevitsky,et al.  Subsynchronous torsional interaction behaviour of wind turbine-generator unit connected to an HVDC system , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[17]  Li Zhiguo Analysis on System Characteristics After Incorporation of ±320 kV/1000 MW VSC-HVDC into Dalian Power Grid , 2013 .

[18]  R. K. Varma,et al.  Modal analysis of Type-1 wind farm connected to series compensated transmission line and LCC HVDC transmission line , 2012, 2012 IEEE Electrical Power and Energy Conference.

[19]  J. G. Slootweg,et al.  Aggregated modelling of wind parks in power system dynamics simulations , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[20]  Chen Yuan Study on transient stability of wind & thermal power transmission system based on PSS and SSSC , 2012 .

[21]  Wang Guodong,et al.  VSC-HVDC System Control for Grid-connection of DIFG Wind Farms , 2012 .

[22]  P. Kundur,et al.  Power system stability and control , 1994 .

[23]  Lingling Fan,et al.  Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network , 2011, IEEE Transactions on Energy Conversion.

[24]  Li Wang,et al.  Comparisons of Damping Controllers for Stability Enhancement of an Offshore Wind Farm Fed to an OMIB System Through an LCC-HVDC Link , 2013, IEEE Transactions on Power Systems.

[25]  Qin Chuan,et al.  Distinguishability analysis of controller parameters with applications to DFIG based wind turbine , 2013 .

[26]  M. Szechtman,et al.  A benchmark model for HVDC system studies , 1991 .