Graded-index plastic optical fiber for deformation sensing

Abstract This paper proposes the use of imperfected graded-index plastic optical fibers as sensing elements in deformation sensors. Use of a graded-index fiber instead of a step-index fiber for bending measurements resulted in an increase in sensitivity. Multi-loop configuration led to an even greater increase in sensitivity, reaching saturation after 15 half-loops. Imperfections implemented on the fiber further increased the sensitivity, although any variation of more than three imperfections, either all on one loop or each on separate loops, brought the sensitivity of the sensor to saturation. The maximal resolution obtained within a 25 mm radius range was 20 μm, with an even greater resolution at smaller ranges. These promising initial results indicate that sensors based on imperfected graded-index plastic optical fibers merit further study.

[1]  Joseba Zubia,et al.  Plastic Optical Fibers: An Introduction to Their Technological Processes and Applications , 2001 .

[2]  Nobuo Takeda,et al.  Detection of transverse cracks by embedded plastic optical fiber in FRP laminates , 1999, Smart Structures.

[3]  D. Gloge,et al.  Bending loss in multimode fibers with graded and ungraded core index. , 1972, Applied optics.

[4]  Hari Singh Nalwa Polymer optical fibers , 2004 .

[5]  Libo Yuan,et al.  Embedded white light interferometer fibre optic strain sensor for monitoring crack-tip opening in concrete beams , 1998 .

[6]  K.S.C. Kuang,et al.  The use of plastic optical fibre sensors for monitoring the dynamic response of fibre composite beams , 2003 .

[7]  Johan Vlekken,et al.  Fiber optic deformation and temperature measurement system for application at underground radioactive waste repositories , 2005, International Conference on Optical Fibre Sensors.

[8]  Daniele Inaudi,et al.  Bridge monitoring by fiber optic deformation sensors: design, emplacement, and results , 1996, Smart Structures.

[9]  Gerard Franklyn Fernando,et al.  An intensity-based optical fibre sensor for fatigue damage detection in advanced fibre-reinforced composites , 1995 .

[10]  M. Nitzan,et al.  Fiber optic sensor for the measurement of respiratory chest circumference changes. , 1999, Journal of biomedical optics.

[11]  Masayuki Morisawa,et al.  A plastic optical fibre sensor for real-time humidity monitoring , 2003 .

[12]  K.S.C. Kuang,et al.  An evaluation of a novel plastic optical fibre sensor for axial strain and bend measurements , 2002 .

[13]  Anatoly Babchenko,et al.  Plastic optical fibre with structural imperfections as a displacement sensor , 2006 .

[14]  E. Nawy,et al.  DEFORMATIONAL BEHAVIOR OF HIGH PERFORMANCE CONCRETE CONTINUOUS COMPOSITE BEAMS REINFORCED WITH PRESTRESSED PRISMS AND INSTRUMENTED WITH BRAGG GRATING FIBER OPTIC SENSORS , 1998 .