Multibeam field emission x-ray system with half-scan reconstruction algorithm.

PURPOSE In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. METHODS The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a corresponding detector segment, and a sample rotation stage. The collimator is placed between the source and the object to restrict the x-ray radiations through the target object only. In this design, all the x-ray beams are activated simultaneously to provide multiple projection views of the object. The detector is virtually segmented and synchronized with the x-ray exposure and the physiological signals when gating is involved. The transmitted x-ray intensity from each beam is collected by the corresponding segment on the detector. After each exposure, the object is rotated by a step angle until sufficient data set is collected. The half-scan reconstruction formula for MBFEX system is derived from the conventional filtered backprojection algorithm. To demonstrate the advantages of the system and method in reducing motion artifacts, the authors performed simulations with both standard and dynamic Shepp-Logan phantoms. RESULTS The numerical results indicate that the proposed multibeam system and the associated half-scan algorithm can effectively reduce the scanning time and improve the image quality for a time-varying object. CONCLUSIONS The MBFEX technique offers an opportunity for the innovation of multisource imaging system.

[1]  Hengyong Yu,et al.  Local ROI Reconstruction via Generalized FBP and BPF Algorithms along More Flexible Curves , 2006, Int. J. Biomed. Imaging.

[2]  Abu-Bakr Al-Mehdi,et al.  Increased Depth of Cellular Imaging in the Intact Lung Using Far-Red and Near-Infrared Fluorescent Probes , 2006, Int. J. Biomed. Imaging.

[3]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[4]  G Allan Johnson,et al.  4-D Micro-CT of the Mouse Heart , 2005, Molecular imaging.

[5]  L. Hedlund,et al.  Micro-CT with respiratory and cardiac gating. , 2004, Medical physics.

[6]  Guohua Cao,et al.  A dynamic micro-CT scanner with a stationary mouse bed using a compact carbon nanotube field emission x-ray tube , 2009, Medical Imaging.

[7]  Otto Zhou,et al.  Stationary scanning x-ray source based on carbon nanotube field emitters , 2005 .

[8]  Jonathan S. Maltz,et al.  Fixed gantry tomosynthesis system for radiation therapy image guidance based on a multiple source x-ray tube with carbon nanotube cathodes. , 2009 .

[9]  Riwa Kishimoto,et al.  Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: case study for hepatic volumetric cine imaging. , 2006, European journal of radiology.

[10]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[11]  E.A. Hoffman,et al.  High-speed three-dimensional X-ray computed tomography: The dynamic spatial reconstructor , 1983, Proceedings of the IEEE.

[12]  R Peng,et al.  A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source , 2009, Physics in medicine and biology.

[13]  Joshua Kim,et al.  Tetrahedron beam computed tomography (TBCT): a new design of volumetric CT system. , 2009, Physics in medicine and biology.

[14]  F Noo,et al.  Redundant data and exact helical cone-beam reconstruction. , 2004, Physics in medicine and biology.

[15]  Tuyen Phan,et al.  Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis. , 2009, Medical physics.

[16]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[17]  Enzhuo Quan,et al.  A Faster Ordered-Subset Convex Algorithm for Iterative Reconstruction , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[18]  X. Calderon-Colon,et al.  Stationary micro-CT scanner using a distributed multi-beam field emission x-ray source: a feasibility study , 2009, Medical Imaging.