Impact of a transparent hood on the performance of total colonoscopy: a randomized controlled trial.

BACKGROUND Clinical demand for total colonoscopy (TCS) is increasing. Improvement of the cecal intubation rate and shortening of the examination time would expand the capacity for TCS. OBJECTIVE To assess the efficacy of a transparent hood attached to the tip of a colonoscope for cecal intubation in TCS. DESIGN Prospective, randomized, controlled study. SETTING Single tertiary-referral center. INTERVENTIONS TCS. MAIN OUTCOME MEASUREMENTS Cecal intubation time and rate, complications, patient discomfort, and detection rate of colonic polyps. METHODS Patients who were to undergo screening and/or surveillance TCS for colorectal cancer were invited to participate in the study. Cecal intubation time and rate, complications, patient discomfort, and detection rate of colonic polyps were evaluated. RESULTS A total of 592 patients enrolled in this study were randomly allocated to the hood group and no-hood group. The mean (SD) cecal intubation time in the hood group and the no-hood group was 10.2 +/- 12.5 minutes and 13.4 +/- 15.8 minutes, respectively (P = .0241). The effect of its use was more prominent in the expert endoscopists group compared with those with moderate experience. The cecal intubation rate and the detection rate of small polyps in the 2 groups were similar. The grade of patient discomfort was significantly lower in the hood group. No complications were encountered with the use of the hood. CONCLUSIONS Use of a transparent hood on the tip of a colonoscope shortened the time required for cecal intubation and decreased patient discomfort; such use was more effective among experts in shortening the examination time.

[1]  D. Lieberman,et al.  Procedural success and complications of large-scale screening colonoscopy. , 2002, Gastrointestinal endoscopy.

[2]  S Halligan,et al.  Why is colonoscopy more difficult in women? , 1996, Gastrointestinal endoscopy.

[3]  D. Lieberman,et al.  Use of colonoscopy to screen asymptomatic adults for colorectal cancer. Veterans Affairs Cooperative Study Group 380. , 2000, The New England journal of medicine.

[4]  H. Ng,et al.  Cap-fitted gastroscopy improves visualization and targeting of lesions. , 2001, Gastrointestinal endoscopy.

[5]  S. Wexner,et al.  A prospective analysis of 13,580 colonoscopies , 2001, Surgical Endoscopy.

[6]  J. Sung,et al.  Improved Colonoscopy Success Rate with a Distally Attached Mucosectomy Cap , 2006, Endoscopy.

[7]  A. Torii,et al.  Usefulness of oblique transparent cylinders in facilitating colonoscopy , 2003 .

[8]  J. Marshall,et al.  Technical proficiency of trainees performing colonoscopy: a learning curve. , 1995, Gastrointestinal endoscopy.

[9]  A. Zaman,et al.  A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope. , 2002, Gastrointestinal endoscopy.

[10]  C. Messina,et al.  Factors that predict incomplete colonoscopy: thinner is not always better , 2000, American Journal of Gastroenterology.

[11]  Y. Urita,et al.  A transparent hood simplifies magnifying observation of the colonic mucosa by colonoscopy. , 1997, Gastrointestinal endoscopy.

[12]  J. Church,et al.  Complete colonoscopy: how often? And if not, why not? , 1994, The American journal of gastroenterology.

[13]  D. Ransohoff,et al.  Risk of advanced proximal neoplasms in asymptomatic adults according to the distal colorectal findings. , 2000, The New England journal of medicine.

[14]  A. Zaman,et al.  Use of a variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope. , 2002 .

[15]  G. Dafnis Technical Considerations and Patient Comfort in Total Colonoscopy with and without a Transparent Cap: Initial Experiences from a Pilot Study , 2000, Endoscopy.

[16]  J. Kang,et al.  Factors affecting insertion time and patient discomfort during colonoscopy. , 2000, Gastrointestinal endoscopy.

[17]  J. Hartikainen,et al.  The Effects of Gender and Age on the Colonoscopic Examination , 2001, Journal of clinical gastroenterology.

[18]  H. Inoue,et al.  Feasibility of the transparent cap-fitted colonoscope for screening and mucosal resection , 1997, Diseases of the colon and rectum.

[19]  C. Williams,et al.  A prospective study of colonoscopy practice in the UK today: are we adequately prepared for national colorectal cancer screening tomorrow? , 2004, Gut.

[20]  Colorectal cancer prevention 2000: screening recommendations of the American College of Gastroenterology , 2000 .

[21]  W. Cohn,et al.  Factors predictive of difficult colonoscopy. , 2001, Gastrointestinal endoscopy.

[22]  D. Rex,et al.  Method of colonoscopy in 42 consecutive patients presenting after prior incomplete colonoscopy. , 2002 .

[23]  D. Rex Effect of Variable Stiffness Colonoscopes on Cecal Intubation Times for Routine Colonoscopy by an Experienced Examiner in Sedated Patients , 2001, Endoscopy.

[24]  Y. Yamaji,et al.  A Randomized Controlled Trial Evaluating the Usefulness of a Transparent Hood Attached to the Tip of the Colonoscope , 2007, The American Journal of Gastroenterology.

[25]  M. Bourke,et al.  A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy. , 2003, Gastrointestinal endoscopy.

[26]  K. Okazaki,et al.  Efficacy of Total Colonoscopy with a Transparent Cap in Comparison with Colonoscopy without the Cap , 1998, Endoscopy.