Optimization of galvanometer scanning for optical coherence tomography.

We study experimentally the effective duty cycle of galvanometer-based scanners (GSs) with regard to three main parameters of the scanning process: theoretical/imposed duty cycle (of the input signal), scan frequency, and scan amplitude. Sawtooth and triangular input signals for the device are considered. The effects of the mechanical inertia of the oscillatory element of the GS are analyzed and their consequences are discussed in the context of optical coherence tomography (OCT) imaging. When the theoretical duty cycle and the scan amplitude are increased to the limit, the saturation of the device is demonstrated for a useful range of scan frequencies by direct measurement of the position of the galvomirror. Investigations of OCT imaging of large samples also validate this saturation, as examplified by the gaps/blurred portions obtained between neighboring images when using both triangular and sawtooth scanning at high scan frequencies. For this latter aspect, the necessary overlap between neighboring B-scans, and therefore between the corresponding volumetric reconstructions of the sample, are evaluated and implemented with regard to the same parameters of the scanning process. OCT images that are free of these artifacts are thus obtained.

[1]  Adrian Bradu,et al.  Surface imaging of metallic material fractures using optical coherence tomography. , 2014, Applied optics.

[2]  Adrian Bradu,et al.  Design and testing of prototype handheld scanning probes for optical coherence tomography , 2014, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  Kye-Sung Lee,et al.  Parallelized multi–graphics processing unit framework for high-speed Gabor-domain optical coherence microscopy , 2014, Journal of biomedical optics.

[4]  Angelika Unterhuber,et al.  Optical coherence tomography today: speed, contrast, and multimodality , 2014, Journal of biomedical optics.

[5]  Stefan Preitl,et al.  Mathematical model of a galvanometer-based scanner: simulations and experiments , 2013, Optical Metrology.

[6]  Virgil-Florin Duma,et al.  Modeling of Risley prisms devices for exact scan patterns , 2013, Optical Metrology.

[7]  Adrian Bradu,et al.  Dual instrument for in vivo and ex vivo OCT imaging in an ENT department , 2012, Biomedical optics express.

[8]  J. D. de Boer,et al.  Angiography of the retina and the choroid with phase-resolved OCT using interval-optimized backstitched B-scans. , 2012, Optics express.

[9]  P. Ferraro,et al.  An automatic method for assembling a large synthetic aperture digital hologram. , 2012, Optics express.

[10]  Virgil-Florin Duma,et al.  Experimental investigations of the scanning functions of galvanometer-based scanners with applications in OCT. , 2011, Applied optics.

[11]  Panomsak Meemon,et al.  Cellular resolution optical coherence microscopy with high acquisition speed for in-vivo human skin volumetric imaging. , 2011, Optics letters.

[12]  Yajun Li Third-order theory of the Risley-prism-based beam steering system. , 2011, Applied optics.

[13]  Kevin P Thompson,et al.  Broadband astigmatism-corrected Czerny-Turner spectrometer. , 2010, Optics express.

[14]  Virgil-Florin Duma,et al.  Optimal scanning function of a galvanometer scanner for an increased duty cycle , 2010 .

[15]  Maciej Wojtkowski,et al.  High-speed optical coherence tomography: basics and applications. , 2010, Applied optics.

[16]  Adrian Gh. Podoleanu,et al.  Perspectives of optical scanning in OCT , 2010, BiOS.

[17]  Hyungsuck Cho,et al.  Optical design of a variable view imaging system with the combination of a telecentric scanner and double wedge prisms. , 2010, Applied optics.

[18]  Yajun Li,et al.  Beam deflection and scanning by two-mirror and two-axis systems of different architectures: a unified approach. , 2008, Applied optics.

[19]  Adrian Gh. Podoleanu,et al.  Combinations of techniques in imaging the retina with high resolution , 2008, Progress in Retinal and Eye Research.

[20]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[21]  Michael W. Jenkins,et al.  In vivo gated 4D imaging of the embryonic heart using optical coherence tomography. , 2007, Journal of biomedical optics.

[22]  Daisuke Miyazaki,et al.  Volumetric display system based on three-dimensional scanning of inclined optical image. , 2006, Optics express.

[23]  John Rogers,et al.  Fast scanning transmissive delay line for optical coherence tomography. , 2005, Optics letters.

[24]  David Saunders,et al.  En-face optical coherence tomography - a novel application of non-invasive imaging to art conservation. , 2005, Optics express.

[25]  P. So,et al.  High-speed, two-photon scanning microscope. , 1999, Applied optics.

[26]  Redmond P. Aylward,et al.  Advances and technologies of galvanometer-based optical scanners , 1999, Optics & Photonics.

[27]  J. S. Gadhok,et al.  Achieving high-duty cycle sawtooth scanning with galvanometric scanners , 1999, Optics & Photonics.

[28]  David A. Jackson,et al.  En-face coherence imaging using galvanometer scanner modulation. , 1998, Optics letters.

[29]  Martin F. Kraus,et al.  Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror. , 2013, Biomedical optics express.

[30]  Pascal Picart,et al.  Analysis and adaptation of convolution algorithms to reconstruct extended objects in digital holography. , 2013, Applied optics.