Effects of solvent on the maximum charge state and charge state distribution of protein ions produced by electrospray ionization

The effects of solvent composition on both the maximum charge states and charge state distributions of analyte ions formed by electrospray ionization were investigated using a quadrupole mass spectrometer. The charge state distributions of cytochrome c and myoglobin, formed from 47%/50%/3% water/solvent/acetic acid solutions, shift to lower charge (higher m/z) when the 50% solvent fraction is changed from water to methanol, to acetonitrile, to isopropanol. This is also the order of increasing gas-phase basicities of these solvents, although other physical properties of these solvents may also play a role. The effect is relatively small for these solvents, possibly due to their limited concentration inside the electrospray interface. In contrast, the addition of even small amounts of diethylamine (<0.4%) results in dramatic shifts to lower charge, presumably due to preferential proton transfer from the higher charge state ions to diethylamine. These results clearly show that the maximum charge states and charge state distributions of ions formed by electrospray ionization are influenced by solvents that are more volatile than water. Addition of even small amounts of two solvents that are less volatile than water, ethylene glycol and 2-methoxyethanol, also results in preferential deprotonation of higher charge state ions of small peptides, but these solvents actually produce an enhancement in the higher charge state ions for both cytochrome c and myoglobin. For instruments that have capabilities that improve with lower m/z, this effect could be taken advantage of to improve the performance of an analysis.

[1]  T. Veenstra Electrospray ionization mass spectrometry in the study of biomolecular non-covalent interactions. , 1999, Biophysical chemistry.

[2]  E. Williams,et al.  Hydration of gas-phase ions formed by electrospray ionization , 1999, Journal of the American Society for Mass Spectrometry.

[3]  K. Siu,et al.  Thermal denaturation of some proteins and its effect on their electrospray mass spectrat , 1991 .

[4]  P. Schnier,et al.  On the maximum charge state and proton transfer reactivity of peptide and protein ions formed by electrospray ionization , 1995, Journal of the American Society for Mass Spectrometry.

[5]  P. Schnier,et al.  Conformations and folding of lysozyme ions in vacuo. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[6]  David E. Clemmer,et al.  Ion Mobility Measurements and their Applications to Clusters and Biomolecules , 1997 .

[7]  E. Williams,et al.  Hydration of gas-phase gramicidin S (M + 2H)2+ ions formed by electrospray: The transition from solution to gas-phase structure , 1997 .

[8]  J. V. Iribarne,et al.  On the evaporation of small ions from charged droplets , 1976 .

[9]  K. Siu,et al.  Is droplet evaporation crucial in the mechanism of electrospray mass spectrometry , 1993 .

[10]  F. McLafferty,et al.  Unit resolution mass spectra of 112 kDa molecules with 3 Da accuracy , 1997 .

[11]  R. Cole,et al.  Disparity between solution‐phase equilibria and charge state distributions in positive‐ion electrospray mass spectrometry , 1994 .

[12]  M. Wilm,et al.  Analytical properties of the nanoelectrospray ion source. , 1996, Analytical chemistry.

[13]  M. Mann,et al.  Electrospray ionization for mass spectrometry of large biomolecules. , 1989, Science.

[14]  C. Cassady,et al.  Effects of cysteic acid groups on the gas-phase reactivity and dissociation of [M + 4H]4+ ions from insulin chain B , 1999, Journal of the American Society for Mass Spectrometry.

[15]  T. Schindler,et al.  FREEZE-DRIED BIOMOLECULES : FT-ICR STUDIES OF THE SPECIFIC SOLVATION OF FUNCTIONAL GROUPS AND CLATHRATE FORMATION OBSERVED BY THE SLOW EVAPORATION OF WATER FROM HYDRATED PEPTIDES AND MODEL COMPOUNDS IN THE GAS PHASE , 1998 .

[16]  K. Siu,et al.  Electrospray mass spectra of protein cations formed in basic solutions , 1994 .

[17]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[18]  Richard D. Smith,et al.  Correlation between the Charge of Proteins in Solution and in the Gas Phase Investigated by Protein Charge Ladders, Capillary Electrophoresis, and Electrospray Ionization Mass Spectrometry , 1998 .

[19]  R. C. Mobley,et al.  Molecular Beams of Macroions , 1968 .

[20]  Brian T. Chait,et al.  Probing conformational changes in proteins by mass spectrometry , 1990 .

[21]  J. Fenn,et al.  Ion formation from charged droplets: Roles of geometry, energy, and time , 1993, Journal of the American Society for Mass Spectrometry.

[22]  Richard D. Smith,et al.  Proton transfer reaction studies of multiply charged proteins in a high mass-to-charge ratio quadrupole mass spectrometer , 1994, Journal of the American Society for Mass Spectrometry.

[23]  L. Pu,et al.  Surreptitious involvement of a metallacycle substituent in metal-mediated alkyne cleavage chemistry , 1990 .

[24]  C. Lebrilla,et al.  Chiral Recognition Is Observed in the Deprotonation Reaction of Cytochrome c by (2R)- and (2S)-2-Butylamine , 1996 .

[25]  Feimeng Zhou,et al.  Changes in bulk solution pH caused by the inherent controlled-current electrolytic process of an electrospray ion source , 1997 .

[26]  R. Tomkins,et al.  Nonaqueous Solution Chemistry , 1981 .

[27]  J. Henion,et al.  The determination of protein, oligonucleotide and peptide molecular weights by ion-spray mass spectrometry. , 1988, Rapid communications in mass spectrometry : RCM.

[28]  Richard D. Smith,et al.  Gas-phase proton transfer reactions involving multiply charged cytochrome c ions and water under thermal conditions , 1992, Journal of the American Society for Mass Spectrometry.

[29]  C. G. Edmonds,et al.  Solvent-induced conformational changes of polypeptides probed by electrospray-ionization mass spectrometry. , 1991, Rapid communications in mass spectrometry : RCM.

[30]  E. Williams Proton transfer reactivity of large multiply charged ions. , 1996, Journal of mass spectrometry : JMS.

[31]  Apparent proton affinities of highly charged peptide ions , 1999, Journal of the American Society for Mass Spectrometry.