A novel control strategy to improve the performances of heated wire humidifiers in artificial neonatal ventilation.

Controlling thermo-hygrometric conditions of gas delivered in neonatal mechanical ventilation shows some unresolved issues due to the design and control strategies implemented in heated wire humidifiers. We perform an in vitro evaluation of humidifier performances, which use a control strategy based on a single-point temperature as feedback, and propose a novel design of the control which consists in pre-warming the gas upwards in the humidification chamber. The ad hoc developed control approach based on a theoretical model is implemented in vitro with and without pre-warming for comparative purposes. Without pre-warming, gas at the chamber outlet needs further post-warming and, depending on the flow rate, the vapour content condensates along the breathing circuit. Whereas, with pre-warming, the proposed control strategy allows us to considerably improve steady-state thermo-hygrometric conditions (T = 37 ± 1 °C, RH = 96% ± 4%) of gas, reaching the Y-piece near to ideal ones in the whole flow rate range, even though a high inlet chamber temperature is required at low flow rate values. The proposed solution, as theoretically predicted, also allows us to limit the vapour condensation along the circuit.

[1]  Sergio Silvestri,et al.  Gas pre-warming for improving performances of heated humidifiers in neonatal ventilation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  François Lellouche,et al.  Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. , 2004, American journal of respiratory and critical care medicine.

[3]  Mark Hochmann,et al.  The effect of inlet gas temperatures on heated humidifier performance. , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[4]  H. Schiffmann Humidification of respired gases in neonates and infants. , 2006, Respiratory care clinics of North America.

[5]  P. Pelosi,et al.  Performance of heated wire humidifiers: an in vitro study. , 2007, Journal of critical care.

[6]  Sergio Silvestri,et al.  Mathematical model and minimal measurement system for optimal control of heated humidifiers in neonatal ventilation. , 2010, Medical engineering & physics.

[7]  Arden L. Buck,et al.  New Equations for Computing Vapor Pressure and Enhancement Factor , 1981 .

[8]  G. Smaldone,et al.  Y-piece temperature and humidification during mechanical ventilation. , 2009, Respiratory care.

[9]  T. Craven,et al.  A change in humidification system can eliminate endotracheal tube occlusion. , 2011, Journal of critical care.

[10]  Y. Jammes,et al.  Airway humidification with a heat and moisture exchanger in mechanically ventilated neonates , 2007, Intensive Care Medicine.

[11]  John G. Webster,et al.  The Measurement, Instrumentation and Sensors Handbook , 1998 .

[12]  T Mashimo,et al.  Performance of heated humidifiers with a heated wire according to ventilatory settings. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[13]  N. Rankin,et al.  Mucociliary function deteriorates in the clinical range of inspired air temperature and humidity , 2004, Intensive Care Medicine.

[14]  Sergio Silvestri,et al.  A transistor based air flow transducer for thermohygrometric control of neonatal ventilatory applications. , 2008, The Review of scientific instruments.

[15]  A. Tarakanova,et al.  Molecular modeling of protein materials: case study of elastin , 2013 .