In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques.

Skin dose is one of the key issues for clinical dosimetry in radiation therapy. Currently planning computer systems are unable to accurately predict dose in the buildup region, leaving ambiguity as to the dose levels actually received by the patient's skin during radiotherapy. This is one of the prime reasons why in vivo measurements are necessary to estimate the dose in the buildup region. A newly developed metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector designed specifically for dose measurements in rapidly changing dose gradients was introduced for accurate in vivo skin dosimetry. The feasibility of this detector for skin dose measurements was verified in comparison with plane parallel ionization chamber and radiochromic films. The accuracy of a commercial treatment planning system (TPS) in skin dose calculations for intensity-modulated radiation therapy treatment of nasopharyngeal carcinoma was evaluated using MOSFET detectors in an anthropomorphic phantom as well as on the patients. Results show that this newly developed MOSFET detector can provide a minimal but highly reproducible intrinsic buildup of 7 mg cm(-2) corresponding to the requirements of personal surface dose equivalent Hp (0.07). The reproducibility of the MOSFET response, in high sensitivity mode, is found to be better than 2% at the phantom surface for the doses normally delivered to the patients. The MOSFET detector agrees well with the Attix chamber and the EBT Gafchromic film in terms of surface and buildup region dose measurements, even for oblique incident beams. While the dose difference between MOSFET measurements and TPS calculations is within measurement uncertainty for the depths equal to or greater than 0.5 cm, an overestimation of up to 8.5% was found for the surface dose calculations in the anthropomorphic phantom study. In vivo skin dose measurements reveal that the dose difference between the MOSFET results and the TPS calculations was on average -7.2%, ranging from -4.3% to -9.2%. The newly designed MOSFET detector encapsulated into a thin water protective film has a minimal reproducible intrinsic buildup recommended for skin dosimetry. This feature makes it very suitable for routine IMRT QA and accurate in vivo skin dosimetry.

[1]  J. Cygler,et al.  MOSFET detectors in quality assurance of tomotherapy treatments. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Anatoly Rosenfeld,et al.  Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors. , 2007, Medical physics.

[3]  R. Cormack,et al.  Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations. , 2007, Medical physics.

[4]  P. Higgins,et al.  Evaluation of surface and superficial dose for head and neck treatments using conventional or intensity-modulated techniques , 2006, Physics in medicine and biology.

[5]  J. Chow,et al.  Study on surface dose generated in prostate intensity-modulated radiation therapy treatment. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[6]  R. Chawla,et al.  Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors. , 2006, Medical physics.

[7]  J. Seuntjens,et al.  Accurate skin dose measurements using radiochromic film in clinical applications. , 2006, Medical physics.

[8]  Tae-Suk Suh,et al.  Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer. , 2005, Medical physics.

[9]  P. Francescon,et al.  Characterization of a new MOSFET detector configuration for in vivo skin dosimetry. , 2005, Medical physics.

[10]  C. De Wagter,et al.  Comparison of build-up dose between Elekta and Varian linear accelerators for high-energy photon beams using radiochromic film and clinical implications for IMRT head and neck treatments , 2005, Physics in medicine and biology.

[11]  Simon J Thomas,et al.  The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT). , 2004, Physics in medicine and biology.

[12]  R Ramaseshan,et al.  Performance characteristics of a microMOSFET as an in vivo dosimeter in radiation therapy. , 2004, Physics in medicine and biology.

[13]  M. Butson,et al.  Effects of temperature variation on MOSFET dosimetry. , 2004, Physics in medicine and biology.

[14]  M. Kaplan,et al.  Comparison of treatment plans using intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for paranasal sinus carcinoma. , 2003, International journal of radiation oncology, biology, physics.

[15]  Ping Xia,et al.  Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma. , 2002, International journal of radiation oncology, biology, physics.

[16]  A. Holmes-Siedle,et al.  Feasibility study of online high-spatial-resolution MOSFET dosimetry in static and pulsed x-ray radiation fields , 2001 .

[17]  P Xia,et al.  Comparison of treatment plans involving intensity-modulated radiotherapy for nasopharyngeal carcinoma. , 2000, International journal of radiation oncology, biology, physics.

[18]  P. Metcalfe,et al.  Measurement of radiotherapy x-ray skin dose on a chest wall phantom. , 2000, Medical physics.

[19]  D P Dearnaley,et al.  Intensity modulated radiation therapy: a clinical review. , 2000, The British journal of radiology.

[20]  Superficial doses from serial tomotherapy delivery. , 2000, Medical physics.

[21]  L. Peters,et al.  Do acute mucosal reactions lead to consequential late reactions in patients with head and neck cancer? , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  P. Metcalfe,et al.  Measurement of off-axis and peripheral skin dose using radiochromic film. , 1998, Physics in medicine and biology.

[23]  P Francescon,et al.  Calibration of a mosfet detection system for 6-MV in vivo dosimetry. , 1998, International journal of radiation oncology, biology, physics.

[24]  T. Mackie,et al.  A dual source photon beam model used in convolution/superposition dose calculations for clinical megavoltage x-ray beams. , 1997, Medical physics.

[25]  R Mohan,et al.  Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation. , 1996, International journal of radiation oncology, biology, physics.

[26]  M. Carolan,et al.  A new radiotherapy surface dose detector:the MOSFET. , 1996, Medical physics.

[27]  A. Rosenfeld,et al.  MOSFET dosimeters: the role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields , 1995 .

[28]  T Kron,et al.  Factors influencing the degree of erythematous skin reactions in humans. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  W F Hanson,et al.  How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams? , 1995, Medical physics.

[30]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[31]  B. Gerbi The response characteristics of a newly designed plane-parallel ionization chamber in high-energy photon and electron beams. , 1993, Medical physics.

[32]  P. Metcalfe,et al.  X-ray surface dose measurements using TLD extrapolation. , 1993, Medical physics.

[33]  J. A. Rawlinson,et al.  Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams. , 1992, Medical physics.

[34]  H D Thames,et al.  Repair capacity and kinetics of human skin during fractionated radiotherapy: erythema, desquamation, and telangiectasia after 3 and 5 year's follow-up. , 1989, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[35]  J. Purdy,et al.  Build-up region of megavoltage photon radiation sources. , 1975, Medical physics.

[36]  J T Whitton,et al.  New values for epidermal thickness and their importance. , 1973, Health physics.