A low power sensor signal processing circuit for implantable biosensor applications

A low power sensor read-out circuit has been implemented in 0.35 µm CMOS technology that consumes only 400 µW of power and occupies an area of 0.66 mm2. The circuit is capable of converting the current signal from any generic biosensor into an amplitude shift keying (ASK) signal. The on-chip potentiostat biases the chemical sensor electrodes to create the sensor current which is then integrated and buffered to generate a square wave with a frequency proportional to the sensor current level. A programmable frequency divider is incorporated to fix the ASK envelope frequency to be inbetween 20 Hz and 20 kHz, which is within the audible range of human hearing. The entire transmitter block operates with a supply voltage as low as 1.5 V, and it can be easily powered up by an external RF source. Test results emulate the simulation results with good agreement and corroborate the efficacy of the designed system.

[1]  E. Renard Implantable glucose sensors for diabetes monitoring , 2004, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[2]  H. Eichenbaum,et al.  Compact miniature microelectrode-telemetry system , 1977, Physiology & Behavior.

[3]  Andreas Nieder,et al.  Miniature stereo radio transmitter for simultaneous recording of multiple single-neuron signals from behaving owls , 2000, Journal of Neuroscience Methods.

[4]  P. Mohseni,et al.  Wireless multichannel biopotential recording using an integrated FM telemetry circuit , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  I Karube,et al.  Development of a thin membrane glucose sensor using beta-type crystalline chitin for implantable biosensor. , 1995, Journal of biotechnology.

[6]  Patrick D Wolf,et al.  A multichannel telemetry system for single unit neural recordings , 2004, Journal of Neuroscience Methods.

[7]  Lei Wang,et al.  Implementation of multichannel sensors for remote biomedical measurements in a microsystems format , 2004, IEEE Transactions on Biomedical Engineering.

[8]  A P Turner,et al.  Recent advances in amperometric glucose biosensors for in vivo monitoring. , 1995, Physiological measurement.

[9]  D. Wenzel,et al.  Low power integrated pressure sensor system for medical applications , 1999 .

[10]  David Gough,et al.  A Continuous, Implantable Lactate Sensor , 1995 .

[11]  L. Leija,et al.  ASIC-based batteryless implantable telemetry microsystem for recording purposes , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[12]  G. S. Wilson,et al.  Progress toward the development of an implantable sensor for glucose. , 1992, Clinical chemistry.

[13]  Christoph Pinkwart,et al.  Miniature three-function transmitting system for single neuron recording, wireless brain stimulation and marking , 1987, Journal of Neuroscience Methods.

[14]  K. Lemke [Electrocatalytic glucose sensor for subcutaneous application]. , 1991, Biomedizinische Technik. Biomedical engineering.