Pneumatic actuator inserts for interface pressure mapping and fit improvement in lower extremity prosthetics

The fit of a prosthetic socket to a residual limb is critical as poor socket fit is one of the leading causes of improper function, discomfort, and skin breakdown. The daily and long term volume fluctuation of a residual limb presents a major challenge to maintaining fit. This work presents the initial efforts to develop adjustable inserts that consisted of arrays of small, sensorized inflatable pressure actuators that can expand based on the volume change. We have fabricated and tested actuator inserts to demonstrate their capability for pressure mapping in a limb-socket interface. We have also shown that the actuators have the capacity to maintain positive displacement under load to accommodate for volume change in a residual limb for improved fit.

[1]  J. Bowker,et al.  Atlas of Limb Prosthetics: Surgical, Prosthetic, and Rehabilitation Principles , 1992 .

[2]  Joan E Sanders,et al.  Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects. , 2004, Journal of rehabilitation research and development.

[3]  Joan E Sanders,et al.  Residual limb volume change: systematic review of measurement and management. , 2011, Journal of rehabilitation research and development.

[4]  Richard M. Greenwald,et al.  Volume Management: Smart Variable Geometry Socket (SVGS) Technology for Lower-Limb Prostheses , 2003 .

[5]  W. Marsden I and J , 2012 .

[6]  Helco G van Keeken,et al.  Comparative roll-over analysis of prosthetic feet. , 2009, Journal of biomechanics.

[7]  A W Buis,et al.  Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee , 1998, Prosthetics and orthotics international.

[8]  A W Buis,et al.  Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket , 1999, Prosthetics and orthotics international.

[9]  Angus McFadyen,et al.  Dynamic interface pressure distributions of two transtibial prosthetic socket concepts. , 2009, Journal of rehabilitation research and development.

[10]  S G Zachariah,et al.  Interface pressure and shear stress changes with amputee weight loss: Case studies from two trans-tibial amputee subjects , 2002, Prosthetics and orthotics international.

[11]  Tracy L Beil,et al.  Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets. , 2002, Journal of rehabilitation research and development.

[12]  J E Sanders,et al.  Mechanical performance of inflatable inserts used in limb prosthetics. , 2001, Journal of rehabilitation research and development.

[13]  P Sewell,et al.  Developments in the transtibial prosthetic socket fitting process: A review of past and present research , 2000, Prosthetics and orthotics international.