X-RAY COMPUTED MICROTOMOGRAPHY OF RUBBER

ABSTRACT In rubber science, X-ray computed microtomography (micro CT) is becoming an increasingly used technique to characterize 3D microstructures. As a first step, experimental methods, limitations, and data analysis are described. A review of published micro CT studies for rubber is reported. Examples of our recent works are presented, including investigations on samples or complex structures, for compact or foam rubbers. Micro CT is used to describe the evolution of microstructures relative to different processing steps, to environmental interaction, and to adaptation to a mechanical deformation. New insights and better understanding of damage mechanisms due to quasistatic, creep, and fatigue solicitations are presented from in situ micro CT experiments. Perspective studies are outlined.

[1]  Olivia Coindreau,et al.  Direct 3D microscale imaging of carbon–carbon composites with computed holotomography , 2003 .

[2]  G. Vignoles,et al.  Benefits of X‐Ray CMT for the Modeling of C/C Composites , 2011 .

[3]  Pierre Charrier,et al.  Fast evaluation of the fatigue lifetime of rubber-like materials based on a heat build-up protocol and micro-tomography measurements , 2010 .

[4]  José Baruchel,et al.  X-Ray Tomography in Material Science , 2000 .

[5]  L. Broutman,et al.  Fracture and fatigue , 1974 .

[6]  X-Ray Computed Tomography on a Cellular Polysiloxane under Compression , 2001 .

[7]  E. Östman,et al.  Application of computed X-ray tomography scanning in the study of thermo-oxidative degradation of thick-walled filled natural rubber vulcanizates , 1992 .

[8]  van Jaw Hans Dommelen,et al.  X‐ray computed tomography‐based modeling of polymeric foams: The effect of finite element model size on the large strain response , 2010 .

[9]  How computed X-ray tomography can be used to study crosslink density in non-filled peroxide cured polyisoprene rubber , 1988 .

[10]  M. Di Michiel,et al.  Simultaneous Tomography and Diffraction Analysis of Creep Damage , 2005, Science.

[11]  S. Calloch,et al.  Evaluation of the fatigue defect population in an elastomer using X‐ray computed micro‐tomography , 2011 .

[12]  E. Östman,et al.  Thermo-Oxidative Degradation of Thick-Walled Rubber Materials Studied by IR-Technique and Computed X-Ray Tomography Scanning , 1990 .

[13]  K. Legorjujago Fatigue initiation and propagation in natural and synthetic rubbers , 2002 .

[14]  W. V. Mars,et al.  Multiaxial fatigue of rubber , 2001 .

[15]  J. Koo,et al.  Quantifying the dispersion of mixture microstructures , 2007, Journal of microscopy.

[16]  E. Thomas,et al.  Advances in SEM of Polymers , 1984 .

[17]  Application of computed X-ray tomography scanning for studying the aging behaviour of thick-walled rubber , 1989 .