Seismic Response of a Historical Masonry Minaret using a Finite Element Model Updated with Operational Modal Testing

This paper presents the earthquake response of a historical masonry minaret after a finite element model updating was undertaken using the information from full scale ambient vibration testing. The Iskenderpaşa historical masonry minaret dating back to the 16th century with a height of 21m located in the city center of Trabzon, Turkey is selected as an application. Analytical modal analysis is performed on the 3D finite element model of the minaret considering field survey and engineering judgments to obtain the analytical frequencies and mode shapes. The field ambient vibration tests on the minaret under natural excitations such as wind loading and human movement are conducted. The Peak Picking and the Stochastic Subspace Identification techniques are used to extract the modal parameters from the ambient vibration test. A good correlation was found among the modal parameters identified from the two techniques. The finite element model of the minaret is updated to minimize the differences between analytically and experimentally estimated modal properties by changing some uncertain modeling parameters such as material properties and boundary conditions. The analytical model of the minaret after finite element model updating is analyzed using the 1992 Erzincan earthquake record, which occurred near the area, to determine the earthquake behavior of the minaret. At the end of the study, maximum differences in the natural frequencies are reduced on average from 27% to 5% and a good agreement is found between analytical and experimental natural frequencies and mode shapes by model updating. Also, it is seen from the earthquake analysis that the displacements increase along the height of the minaret and the maximum and minimum principal stresses occur at the region of the transition segment and the cylindrical body.

[1]  T. K. Kundra,et al.  Comparative study of model updating methods using simulated experimental data , 2002 .

[2]  Julius S. Bendat,et al.  Engineering Applications of Correlation and Spectral Analysis , 1980 .

[3]  James M. W. Brownjohn VIBRATION CHARACTERISTICS OF A SUSPENSION FOOTBRIDGE , 1997 .

[4]  Poul Henning Kirkegaard,et al.  Theory of Covariance Equivalent ARMAV Models of Civil Engineering Structures , 1995 .

[5]  Chih-Chen Chang,et al.  AMBIENT VIBRATION OF LONG-SPAN CABLE-STAYED BRIDGE , 2001 .

[6]  Bart De Moor,et al.  Subspace Identification for Linear Systems: Theory ― Implementation ― Applications , 2011 .

[7]  Paul Reynolds,et al.  Modal testing and FE model tuning of a lively footbridge structure , 2006 .

[8]  Chih-Chen Chang,et al.  Finite-Element Model Updating for the Kap Shui Mun Cable-Stayed Bridge , 2001 .

[9]  Andreas Johann Felber,et al.  Development of a hybrid bridge evaluation system , 1994 .

[10]  B. Peeters,et al.  Reference based stochastic subspace identification in civil engineering , 1999 .

[11]  Carlos E. Ventura,et al.  EFFECTIVE USE OF AMBIENT VIBRATION MEASUREMENTS FOR MODAL UPDATING OF A 48 STOREY BUILDING IN VANCOUVER, CANADA , 2002 .

[12]  Larry C. Andrews,et al.  Random Data Analysis , 2012 .

[13]  C. Modena,et al.  Experimental and numerical analysis for the strengthening intervention of the bell-tower of St. Sisto’s Church in Bergamo , 2006 .

[14]  C. A Prato,et al.  Experimental and numerical determination of the dynamic properties of the reactor building of Atucha II NPP , 1998 .

[15]  R. Cantieni,et al.  EXPERIMENTAL METHODS USED IN SYSTEM IDENTIFICATION OF CIVIL ENGINEERING STRUCTURES , 2004 .

[16]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[17]  Wei-Xin Ren,et al.  EMD-based stochastic subspace identification of structures from operational vibration measurements , 2005 .

[18]  Anthony Duncan Jefferson,et al.  Experimental Investigations into Seismic Failure of High Arch Dams , 2000 .

[19]  Tong Zhao,et al.  Experimental and Analytical Modal Analysis of Steel Arch Bridge , 2004 .

[20]  Fabrizio Vestroni,et al.  Dynamic identification of a masonry building using forced vibration tests , 2005 .

[21]  Temel Türker,et al.  Modal testing and finite element model calibration of an arch type steel footbridge , 2007 .

[22]  Salvador Ivorra A MASONRY BELL-TOWER ASSESSMENT BY MODAL TESTING , 2007 .

[23]  Nuno M. M. Maia,et al.  Theoretical and Experimental Modal Analysis , 1997 .

[24]  Qiusheng Li,et al.  Finite element model updating for a high-rise structure based on ambient vibration measurements , 2004 .

[25]  Luigia Binda Survey and Investigation for the Diagnosis of Damaged Masonry Structures: the "Torrazzo of Cremona , 2000 .

[26]  Wei-Xin Ren,et al.  Structural Finite Element Model Updating Using Ambient Vibration Test Results , 2005 .

[27]  J. Juang Applied system identification , 1994 .

[28]  H. Saunders,et al.  Finite element procedures in engineering analysis , 1982 .

[29]  H. Van der Auweraer,et al.  A frequency-domain maximum likelihood approach for the extraction of modal parameters from output-only data , 1998 .

[30]  Palle Andersen,et al.  Modal Identification from Ambient Responses using Frequency Domain Decomposition , 2000 .

[31]  Paul Reynolds,et al.  Finite element modelling and updating of a lively footbridge: The complete process , 2007 .

[32]  James M. W. Brownjohn,et al.  Ambient vibration survey of the fatih sultan mehmet (second Bosporus) suspension bridge , 1992 .

[33]  Bart Peeters,et al.  System identification and damage detection in civil engineering , 2000 .

[34]  D. J. Ewins,et al.  Modal Testing: Theory and Practice , 1984 .

[35]  Luigia Binda,et al.  On-site investigation on the remains of the Cathedral of Noto , 2003 .

[36]  Carmelo Gentile,et al.  Ambient vibration testing of historic masonry towers for structural identification and damage assessment , 2007 .

[37]  Carlos E. Ventura,et al.  Automated Model Updating Using Ambient Vibration Data from a 48-storey Building in Vancouver , .

[38]  Anna Anzani,et al.  The failure of ancient towers : Problems of their safety assessment , 1997 .

[39]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1987 .

[40]  Geert Degrande,et al.  Finite element modelling of a silo based on experimental modal analysis , 2006 .

[41]  Thomas G. Carne,et al.  The Natural Excitation Technique (NExT) for modal parameter extraction from operating wind turbines , 1993 .

[42]  Saadet Toker,et al.  MATHEMATICAL MODELING AND FINITE ELEMENT ANALYSIS OF MASONRY ARCH BRIDGES , 2004 .

[43]  Temel Türker,et al.  Modal Testing, Finite-Element Model Updating, and Dynamic Analysis of an Arch Type Steel Footbridge , 2009 .

[44]  Paul Reynolds,et al.  A remote monitoring system for stadia dynamics , 2004 .