A new method for assessing arteriolar diameter and hemodynamic resistance using image analysis of vessel lumen.

To characterize the nonuniform diameter response in a blood vessel after a given stimulus (e.g., arteriolar conducted response), frequent serial diameter measurements along the vessel length are required. We used an advanced image analysis algorithm (the "discrete dynamic contour") to develop a quick, reliable method for serial luminal diameter measurements along the arteriole visualized by intravital video microscopy. With the use of digitized images of the arteriole and computer graphics, the method required an operator to mark the image of the two inner edges of the arteriole at several places along the arteriolar length. The algorithm then "filled in" these marks to generate two continuous contours that "hugged" these edges. A computer routine used these contours to determine luminal diameters every 20 microm. Based on these diameters and on Poiseuille's law, the routine also estimated the hemodynamic resistance of the blood vessel. To demonstrate the usefulness of the method, we examined the character of spatial decay of KCl-induced conducted constriction along approximately 500-microm-long arteriolar segments and the KCl-induced increase in hemodynamic resistance computed for these segments. The decay was only modestly fitted by a simple exponential, and the computed increase in resistance (i.e., 5- to 70-fold) was only modestly predicted by resistance increase based on our mathematical model involving measurements at two arteriolar sites (Tyml K, Wang X, Lidington D, and Oullette Y. Am J Physiol Heart Circ Physiol 281: H1397-H1406, 2001). We conclude that our method provides quick, reliable serial diameter measurements. Because the change in hemodynamic resistance could serve as a sensitive index of conducted response, use of this index in studies of conducted response may lead to new mechanistic insights on the response.

[1]  N. Holstein-Rathlou,et al.  Angiotensin II modulates conducted vasoconstriction to norepinephrine and local electrical stimulation in rat mesenteric arterioles. , 1999, Cardiovascular research.

[2]  S Magers,et al.  Real-time measurement of microvascular dimensions using digital cross-correlation image processing. , 1992, Journal of vascular research.

[3]  G. G. Emerson,et al.  Conduction of hyperpolarization along hamster feed arteries: augmentation by acetylcholine. , 2002, American journal of physiology. Heart and circulatory physiology.

[4]  M. Moskowitz,et al.  ACh dilates pial arterioles in endothelial and neuronal NOS knockout mice by NO-dependent mechanisms. , 1996, The American journal of physiology.

[5]  A. Bharath,et al.  Computer algorithms for the automated measurement of retinal arteriolar diameters , 2001, The British journal of ophthalmology.

[6]  T. Neild,et al.  Measurement of arteriole diameter changes by analysis of television images. , 1989, Blood vessels.

[7]  W. Sessa,et al.  Vasomotor control in arterioles of the mouse cremaster muscle , 2000, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[8]  B. Duling,et al.  Heterogeneity in conducted arteriolar vasomotor response is agonist dependent. , 1991, The American journal of physiology.

[9]  K. Willecke,et al.  Impaired conduction of vasodilation along arterioles in connexin40-deficient mice. , 2000, Circulation research.

[10]  C. Ellis,et al.  Heterogeneity of capillary diameters in skeletal muscle of the frog. , 1983, Microvascular research.

[11]  J. Faber,et al.  Interactions between alpha-adrenoceptors and adenosine receptors on microvascular smooth muscle. , 1991, The American journal of physiology.

[12]  S S Segal,et al.  Conduction of vasomotor responses in arterioles: a role for cell-to-cell coupling? , 1989, The American journal of physiology.

[13]  D A Steinman,et al.  A semi-automatic technique for measurement of arterial wall from black blood MRI. , 2001, Medical physics.

[14]  D. Lidington,et al.  Lipopolysaccharide reduces intercellular coupling in vitro and arteriolar conducted response in vivo. , 2001, American journal of physiology. Heart and circulatory physiology.

[15]  Max A. Viergever,et al.  A discrete dynamic contour model , 1995, IEEE Trans. Medical Imaging.